| Literature DB >> 24488177 |
Ashleen Knutsen1, Tigran Avoian, Sean L Borkowski, Edward Ebramzadeh, Lewis E Zionts, Sophia N Sangiorgio.
Abstract
PURPOSE: Determining the magnitude of displacement in pediatric lateral humeral condyle fractures can be difficult. The purpose of this study was to (1) assess the effect of forearm rotation on true fracture displacement using a cadaver model and to (2) determine the accuracy of radiographic measurements of the fracture gap.Entities:
Year: 2014 PMID: 24488177 PMCID: PMC3935020 DOI: 10.1007/s11832-014-0553-8
Source DB: PubMed Journal: J Child Orthop ISSN: 1863-2521 Impact factor: 1.548
Fig. 1Internal oblique radiograph positioning: arm extended, forearm pronated, anterior surface of elbow at 45 degrees
Fig. 2Anteroposterior (a) and lateral (b) radiographs of simulated lateral condyle fractures. Motion-capture flags, mounted on k-wires and attached to the proximal humerus and distal fracture fragment, are seen in the radiographs
Fig. 3Schematic illustration of the simulated fracture specimen in the holding device: A plexiglass jig, B ball joint and steel pot to hold the proximal humerus, C motion-capture flags, D mini-table for hand to rest on
Fig. 4Illustration of points used to measure true displacement (arrows) using the motion-capture system and radiographic locations used to measure apparent displacement (double arrows) of the lateral edge of the fracture site (a) and of the posterior edge of the fracture site (b)
Lateral edge measurements
| True displacement (by motion tracker) (mm) | Apparent displacement (by radiograph) (mm) | ||
|---|---|---|---|
| ‘Pure’ supination | 3.5 ± 2.0 | 1.6 ± 0.5 | 0.16 |
| ‘Pure’ 90° (neutral) | 4.0 ± 2.1 | 1.7 ± 0.7 | 0.10 |
| ‘Pure’ pronation | 3.5 ± 2.3 | 1.2 ± 0.6 | 0.14 |
| ‘Hinged’ supination | 4.4 ± 2.1 | 2.2 ± 1.2 | 0.08 |
| ‘Hinged’ pronation | 3.7 ± 2.7 | 2.1 ± 2.2 | 0.03 |
Values reported as mean ± standard deviation. P value from paired-samples t test comparing true and apparent displacements
Posterior edge measurements
| True displacement (by motion tracker) (mm) | Apparent displacement (by radiograph) (mm) | ||
|---|---|---|---|
| ‘Pure’ supination | 5.9 ± 4.3 | 1.6 ± 0.9 | 0.22 |
| ‘Pure’ 90° (neutral) | 6.6 ± 4.9 | 1.6 ± 1.2 | 0.20 |
| ‘Pure’ pronation | 6.4 ± 5.0 | 1.9 ± 1.2 | 0.27 |
| ‘Hinged’ supination | 6.1 ± 5.3 | 1.7 ± 1.1 | 0.30 |
| ‘Hinged’ pronation | 7.9 ± 6.1 | 1.9 ± 1.0 | 0.24 |
Values reported as mean ± standard deviation. P value from paired-samples t test comparing true and apparent displacements