A case of nosocomial Legionella pneumonia associated with a contaminated hospital cooling tower.

Kayo Osawa1, Katsumi Shigemura2, Yasuhisa Abe1, Takumi Jikimoto1, Hiroyuki Yoshida1, Masato Fujisawa3, Soichi Arakawa4.   

Abstract

We report the epidemiological investigation of a nosocomial pneumonia case due to Legionella pneumophila linked to a contaminated hospital cooling tower in an immune-compromised patient. A 73-year-old female patient was diagnosed with nosocomial Legionella pneumonia proven by a culture of L. pneumophila serogroup 1 from bronchoalveolar lavage fluid. Two strains isolated from the patient and two strains isolated from two cooling towers were found to be identical using repetitive-sequence-based-PCR with a 95% probability. This Legionella pneumonia case might be caused by aerosol from cooling towers on the roof of the hospital building which was contaminated by L. pneumophila. We increased up the temperature of hot water supply appropriately for prevention of Legionella breeding in an environment of patients' living. On the other hand, as the maintenance of cooling tower, we increased the frequency of Legionella culture tests from twice a year to three times a year. In addition, we introduced an automated disinfectants insertion machine and added one antiseptic reagent (BALSTER ST-40 N, Tohzai Chemical Industry Co., Ltd., Kawasaki, Japan) after this Legionella disease, and thereafter, we have no additional cases of Legionella disease or detection of Legionella spp. from the cooling tower or hot water supply. This case demonstrates the importance of detecting the infection source and carrying out environmental maintenance in cooperation with the infection control team.
Copyright © 2013 Japanese Society of Chemotherapy and the Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cooling tower; Legionella; Nosocomial infection; Rep-PCR

Mesh:

Year:  2013        PMID: 24462430     DOI: 10.1016/j.jiac.2013.07.007

Source DB:  PubMed          Journal:  J Infect Chemother        ISSN: 1341-321X            Impact factor:   2.211


  8 in total

1.  Hospital water and opportunities for infection prevention.

Authors:  Brooke K Decker; Tara N Palmore
Journal:  Curr Infect Dis Rep       Date:  2014-10       Impact factor: 3.725

2.  csrR, a Paralog and Direct Target of CsrA, Promotes Legionella pneumophila Resilience in Water.

Authors:  Zachary D Abbott; Helen Yakhnin; Paul Babitzke; Michele S Swanson
Journal:  MBio       Date:  2015-06-09       Impact factor: 7.867

3.  Dendrimers and Polyamino-Phenolic Ligands: Activity of New Molecules Against Legionella pneumophila Biofilms.

Authors:  Elisa Andreozzi; Federica Barbieri; Maria F Ottaviani; Luca Giorgi; Francesca Bruscolini; Anita Manti; Michela Battistelli; Luigia Sabatini; Anna Pianetti
Journal:  Front Microbiol       Date:  2016-03-09       Impact factor: 5.640

4.  Spatial structuring of a Legionella pneumophila population within the water system of a large occupational building.

Authors:  Sophia David; Massimo Mentasti; Sandra Lai; Lalita Vaghji; Derren Ready; Victoria J Chalker; Julian Parkhill
Journal:  Microb Genom       Date:  2018-10-12

5.  Seeding and Establishment of Legionella pneumophila in Hospitals: Implications for Genomic Investigations of Nosocomial Legionnaires' Disease.

Authors:  Sophia David; Baharak Afshar; Massimo Mentasti; Christophe Ginevra; Isabelle Podglajen; Simon R Harris; Victoria J Chalker; Sophie Jarraud; Timothy G Harrison; Julian Parkhill
Journal:  Clin Infect Dis       Date:  2017-05-01       Impact factor: 20.999

6.  Clusters of Healthcare-Associated Legionnaires' Disease in Two Hospitals of Central Greece.

Authors:  Maria A Kyritsi; Varvara A Mouchtouri; Anna Katsiafliaka; Foteini Kolokythopoulou; Elias Plakokefalos; Vasileios Nakoulas; George Rachiotis; Christos Hadjichristodoulou
Journal:  Case Rep Infect Dis       Date:  2018-08-15

7.  Author Response to Comments on "Rolling epidemic of Legionnaires' disease outbreaks in small geographic areas".

Authors:  C Raina MacIntyre; Amalie Dyda; Chau Minh Bui; Abrar Ahmad Chughtai
Journal:  Emerg Microbes Infect       Date:  2018-09-05       Impact factor: 7.163

8.  Effect of pollutant source location on air pollutant dispersion around a high-rise building.

Authors:  Erfan Keshavarzian; Ruizhi Jin; Kejun Dong; Kenny C S Kwok; Yu Zhang; Ming Zhao
Journal:  Appl Math Model       Date:  2020-01-15       Impact factor: 5.129

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.