Literature DB >> 24456758

Micro- and nanotopography with extracellular matrix coating modulate human corneal endothelial cell behavior.

Stephanie Koo1, Rizwan Muhammad2, Gary S L Peh3, Jodhbir S Mehta4, Evelyn K F Yim5.   

Abstract

The human corneal endothelium plays an important role in maintaining corneal transparency. Human corneal endothelial cells have limited regenerative capability in vivo. Consequently, endothelial dysfunction can occur following corneal endothelial trauma or inherited diseases. To restore endothelial function, corneal transplantation is needed. However, there is a worldwide shortage of donor corneas, motivating the development of a tissue-engineered graft alternative using cultivated endothelial cells. To induce in vitro cell proliferation, much effort has been made to improve culture conditions and to mimic the native extracellular microenvironment. We incorporated topographical and biochemical cues in our in vitro culture of human corneal endothelial cell line B4G12 (HCEC-B4G12) and hypothesized that manipulation of the extracellular environment can modulate cell proliferation, morphometry and phenotype. The topographies tested were nanopillars, microwells and micropillars on polydimethylsiloxane, while the biochemical factors were extracellular matrix protein coatings of fibronectin-collagen I (FC), FNC® coating mix (FNC) and laminin-chondroitin sulfate (LC). Cellular morphometry, Na(+)/K(+)-ATPase and zona occludens 1 (ZO-1) gene and protein expression were analyzed 3days after cells had formed a confluent monolayer. The cell circularity on all patterns and coatings was above 0.78. On all coatings, cell area was the lowest on micropillars. The coefficient of variation (CV) of the cell area was the lowest on nanopillars with an LC coating. With an FC coating, micropillars induced a better cellular outcome as the cells had the greatest circularity, smallest cell area and highest Na(+)/K(+)-ATPase and ZO-1 gene and protein expression. With the LC coating, HCECs grown on nanopillars resulted in the lowest CV of the cell area and the highest ZO-1 gene expression. Thus, HCEC-B4G12 morphometry and phenotype can be improved using different topographical and biochemical cues.
Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cell proliferation; Extracellular matrix protein; HCEC-B4G12; Substrate topography; Tissue engineering

Mesh:

Substances:

Year:  2014        PMID: 24456758     DOI: 10.1016/j.actbio.2014.01.015

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  15 in total

Review 1.  Biomechanical relationships between the corneal endothelium and Descemet's membrane.

Authors:  Maryam Ali; VijayKrishna Raghunathan; Jennifer Y Li; Christopher J Murphy; Sara M Thomasy
Journal:  Exp Eye Res       Date:  2016-09-14       Impact factor: 3.467

Review 2.  3D Microfabricated Scaffolds and Microfluidic Devices for Ocular Surface Replacement: a Review.

Authors:  Elisabetta Prina; Pritesh Mistry; Laura E Sidney; Jing Yang; Ricky D Wildman; Marina Bertolin; Claudia Breda; Barbara Ferrari; Vanessa Barbaro; Andrew Hopkinson; Harminder S Dua; Stefano Ferrari; Felicity R A J Rose
Journal:  Stem Cell Rev Rep       Date:  2017-06       Impact factor: 5.739

3.  The injection of DisCoVisc into the anterior chamber improved corneal preservation and transplantation for cornea blind patients.

Authors:  Bing Li; Li Chen; Yihui Chen; Jiajun Lu; Hao Liu; Yu Liu; Panpan Yao; Rui Liu; Minjie Sheng
Journal:  Am J Transl Res       Date:  2017-09-15       Impact factor: 4.060

4.  A high-throughput microfluidic method for fabricating aligned collagen fibrils to study Keratocyte behavior.

Authors:  Kevin H Lam; Pouriska B Kivanany; Kyle Grose; Nihan Yonet-Tanyeri; Nesreen Alsmadi; Victor D Varner; W Matthew Petroll; David W Schmidtke
Journal:  Biomed Microdevices       Date:  2019-11-18       Impact factor: 2.838

5.  Lithography-free fabrication of reconfigurable substrate topography for contact guidance.

Authors:  Pitirat Pholpabu; Stephen Kustra; Haosheng Wu; Aditya Balasubramanian; Christopher J Bettinger
Journal:  Biomaterials       Date:  2014-11-20       Impact factor: 12.479

Review 6.  Substrates for Expansion of Corneal Endothelial Cells towards Bioengineering of Human Corneal Endothelium.

Authors:  Jesintha Navaratnam; Tor P Utheim; Vinagolu K Rajasekhar; Aboulghassem Shahdadfar
Journal:  J Funct Biomater       Date:  2015-09-11

7.  Therapy of corneal endothelial dysfunction with corneal endothelial cell-like cells derived from skin-derived precursors.

Authors:  Lin Shen; Peng Sun; Canwei Zhang; Le Yang; Liqun Du; Xinyi Wu
Journal:  Sci Rep       Date:  2017-10-17       Impact factor: 4.379

8.  Corneal epithelial cells exposed to shear stress show altered cytoskeleton and migratory behaviour.

Authors:  Sara Molladavoodi; Matthew Robichaud; David Wulff; Maud Gorbet
Journal:  PLoS One       Date:  2017-06-29       Impact factor: 3.240

9.  In vitro biomimetic platforms featuring a perfusion system and 3D spheroid culture promote the construction of tissue-engineered corneal endothelial layers.

Authors:  Shanyi Li; Yuting Han; Hao Lei; Yingxin Zeng; Zekai Cui; Qiaolang Zeng; Deliang Zhu; Ruiling Lian; Jun Zhang; Zhe Chen; Jiansu Chen
Journal:  Sci Rep       Date:  2017-04-10       Impact factor: 4.379

Review 10.  Engineering topography: Effects on corneal cell behavior and integration into corneal tissue engineering.

Authors:  Sijia Xiong; HuiChang Gao; Lanfeng Qin; Yong-Guang Jia; Li Ren
Journal:  Bioact Mater       Date:  2019-10-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.