The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to the postoperative changes in left ventricular (LV) mass and function. Forty patients with aortic stenosis undergoing valve replacement with a stentless (20 patients) or a stented (20 patients) bioprosthesis were evaluated early (baseline), 1 year, and 2 years after operation. Left ventricular mass index was calculated with the corrected American Society of Echocardiography formula. The relative changes between end-diastole and end-systole in LV mid-wall radius, length, and volume (ejection fraction) were determined with a previously validated model for dynamic geometry of the left ventricle. Overall, a significant decrease was found in LV mass index (from 155 +/- 30 to 112 +/- 23 g/m(2); P <.001) and a significant increase in longitudinal shortening (from 0.12 +/- 0.11 to 0.22 +/- 0.08; P <. 001), and ejection fractions (from 0.67 +/- 0.11 to 0.71 +/- 0.10; P =.017). No significant change was found in the mid-wall radius shortening fraction. Two years after surgery, the extent of LV mass regression was greater in stentless bioprostheses (-51 +/- 18 vs -35 +/- 17 g/m(2); P =.01), though the average mass index was similar in both groups (114 +/- 26 vs 110 +/- 20 g/m(2)). Also at 2 years, the longitudinal shortening fraction was greater in patients with a stentless bioprosthesis (0.25 +/- 0.07 vs 0.18 +/- 0.08; P =.03). In conclusion, this study suggests that the superior hemodynamic performance of stentless bioprostheses may have some benefits with regard to LV mass regression and function after aortic valve replacement. The significance of these benefits in terms of prognosis remains to be determined.

Entities:  

Mesh:

Year:  1999        PMID: 10552360     DOI: 10.1016/s0894-7317(99)70152-5

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  [Risk of perioperative mortality and complications following biological aortic valve replacement in elderly patients: stented vs unstented bioprotheses].

Authors:  J Ennker; I Florath; U Rosendahl; S Bauer; E von Hodenberg; I C Ennker
Journal:  Z Kardiol       Date:  2001-12

2.  Mid term outcome and quality of life after aortic valve replacement in elderly people: mechanical versus stentless biological valves.

Authors:  I Florath; A Albert; U Rosendahl; T Alexander; I C Ennker; J Ennker
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

3.  Early regression of severe left ventricular hypertrophy after transcatheter aortic valve replacement is associated with decreased hospitalizations.

Authors:  Brian R Lindman; William J Stewart; Philippe Pibarot; Rebecca T Hahn; Catherine M Otto; Ke Xu; Richard B Devereux; Neil J Weissman; Maurice Enriquez-Sarano; Wilson Y Szeto; Raj Makkar; D Craig Miller; Stamatios Lerakis; Samir Kapadia; Bruce Bowers; Kevin L Greason; Thomas C McAndrew; Yang Lei; Martin B Leon; Pamela S Douglas
Journal:  JACC Cardiovasc Interv       Date:  2014-06       Impact factor: 11.195