Literature DB >> 24445751

Valve-in-valve implantations: is this the new standard for degenerated bioprostheses? Review of the literature.

Krys Milburn1, Vinayak Bapat, Martyn Thomas.   

Abstract

Transcatheter aortic valve implantation has established itself as an alternative treatment for patients with valvular disease. In the current context of increasing bioprosthetic valve implants and an ageing population with growing comorbidities, a less invasive approach to the treatment of bioprosthetic dysfunction would be an appealing alternative to the standard of care. Transcatheter valve-in-valve implantation could be an alternative for patients who are deemed to be a high surgical risk. The valve-in-valve procedure is a minimally invasive percutaneous procedure where a valve can be implanted directly within a failing bioprosthetic valve. This technique can be applied to dysfunctional aortic bioprosthetic valves and can also be used in the pulmonary and atrioventricular valve bioprosthesis. We review the current literature to assess whether this technique may be the new standard for degenerated bioposthesis.

Entities:  

Mesh:

Year:  2014        PMID: 24445751     DOI: 10.1007/s00392-013-0653-3

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  93 in total

1.  Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies.

Authors:  Philippe Généreux; Stuart J Head; Nicolas M Van Mieghem; Susheel Kodali; Ajay J Kirtane; Ke Xu; Craig Smith; Patrick W Serruys; A Pieter Kappetein; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2012-04-11       Impact factor: 24.094

2.  Reducing operative mortality in valvular reoperations: the "valve in ring" procedure.

Authors:  Filip Casselman; Sebastiaan Martens; Bernard De Bruyne; Ivan Degrieck
Journal:  J Thorac Cardiovasc Surg       Date:  2010-09-19       Impact factor: 5.209

3.  Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: the first valve in valve procedure using the Corevalve Revalving system.

Authors:  Peter Wenaweser; Lutz Buellesfeld; Ulrich Gerckens; Eberhard Grube
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-01       Impact factor: 2.692

4.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

5.  Rescue valve-in-valve implantations in second generation transapical transcatheter aortic valve prostheses.

Authors:  Arnaud Van Linden; Johannes Blumenstein; Thomas Walther; Helge Möllmann; Won Keun Kim; Christian Hamm; Jörg Kempfert
Journal:  Clin Res Cardiol       Date:  2012-11-06       Impact factor: 5.460

6.  Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Authors:  Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N Anderson; Olaf Wendler
Journal:  Circulation       Date:  2010-06-21       Impact factor: 29.690

7.  Carpentier-Edwards porcine bioprostheses: clinical performance assessed by actual analysis.

Authors:  W R Jamieson; R T Miyagishima; L H Burr; S V Lichtenstein; G J Fradet; M T Janusz
Journal:  J Heart Valve Dis       Date:  2000-07

8.  Physiological consequences of percutaneous pulmonary valve implantation: the different behaviour of volume- and pressure-overloaded ventricles.

Authors:  Louise Coats; Sachin Khambadkone; Graham Derrick; Marina Hughes; Rod Jones; Bryan Mist; Denis Pellerin; Jan Marek; John E Deanfield; Philipp Bonhoeffer; Andrew M Taylor
Journal:  Eur Heart J       Date:  2007-06-26       Impact factor: 29.983

9.  Recurrent mitral regurgitation and risk factors for early and late mortality after mitral valve repair for functional ischemic mitral regurgitation.

Authors:  Traves D Crabtree; Marci S Bailey; Marc R Moon; Nabil Munfakh; Michael K Pasque; Jennifer S Lawton; Nader Moazami; Kristen A Aubuchon; Ashraf S Al-Dadah; Ralph J Damiano
Journal:  Ann Thorac Surg       Date:  2008-05       Impact factor: 4.330

10.  First implantation of the CE-marked transcatheter Sapien pulmonic valve in Europe.

Authors:  Peter Ewert; Eric Horlick; Felix Berger
Journal:  Clin Res Cardiol       Date:  2010-09-18       Impact factor: 5.460

View more
  12 in total

1.  Case report: Cerebral stentretreiver thrombectomy of an embolized valve fragment after valve in valve TAVI.

Authors:  Jan-Erik Gülker; Peter Schott; Marcus Katoh; Alexander Bufe
Journal:  Clin Res Cardiol       Date:  2015-10-29       Impact factor: 5.460

Review 2.  Lack of Accessible Data on Prosthetic Heart Valves.

Authors:  Michelle Frank; Giulia Ganzoni; Christoph Starck; Jürg Grünenfelder; Roberto Corti; Christiane Gruner; David Hürlimann; Felix C Tanner; Rolf Jenni; Matthias Greutmann; Patric Biaggi
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-08       Impact factor: 2.357

3.  Antegrade transcatheter mitral valve-in-valve implantation with combined atrial septal defect closure.

Authors:  Felipe C Fuchs; Christoph Hammerstingl; Jan-Malte Sinning; Fritz Mellert; Nikos Werner; Eberhard Grube; Georg Nickenig
Journal:  Clin Res Cardiol       Date:  2015-11-09       Impact factor: 5.460

4.  Thrombosis of TAVI prosthesis-cause for concern or innocent bystander? A comment and review of currently available data.

Authors:  Stephan H Schirmer; Felix Mahfoud; Peter Fries; Bruno Scheller
Journal:  Clin Res Cardiol       Date:  2016-12-19       Impact factor: 5.460

5.  Tricuspid valve-in-valve implantation for failing bioprosthetic valves: an evolving standard of care.

Authors:  Sidakpal S Panaich; Mackram F Eleid
Journal:  Ann Transl Med       Date:  2016-10

6.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Authors:  Caitlin Martin; Wei Sun
Journal:  Ann Biomed Eng       Date:  2016-10-12       Impact factor: 3.934

7.  Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: A fatigue simulation study.

Authors:  Caitlin Martin; Wei Sun
Journal:  J Biomech       Date:  2015-08-07       Impact factor: 2.712

8.  Successful transfemoral Edwards SAPIEN 3 valve in valve implantation in a patient with a degenerated aortic bioprosthesis associated with severe paravalvular aortic regurgitation.

Authors:  Klaudija Bijuklic; Lorenz Hansen; Julian Witt; Joachim Schofer
Journal:  Clin Res Cardiol       Date:  2014-09-17       Impact factor: 5.460

9.  Effect of severe bioprosthetic valve tissue ingrowth and inflow calcification on valve-in-valve performance.

Authors:  Hoda Hatoum; Jennifer Dollery; Scott M Lilly; Juan A Crestanello; Lakshmi Prasad Dasi
Journal:  J Biomech       Date:  2018-05-04       Impact factor: 2.712

10.  Percutaneous pulmonary and tricuspid valve implantations: An update.

Authors:  Robert Wagner; Ingo Daehnert; Philipp Lurz
Journal:  World J Cardiol       Date:  2015-04-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.