Literature DB >> 24441884

Direct ultrasound methods: a confirmatory technique for proper endotracheal intubation in the emergency department.

Saeed Abbasi1, Davood Farsi, Mohammad A Zare, Majid Hajimohammadi, Mahdi Rezai, Peyman Hafezimoghadam.   

Abstract

BACKGROUND AND
OBJECTIVE: Early confirmation of incorrect endotracheal tube (ETT) placement is of vital importance when performing emergency airway management. No ideal confirmation technique has been proposed under all circumstances. Recently, ultrasonography was suggested as a useful tool for confirmation of correct positioning of the ETT. The aim of this study is to assess the diagnostic accuracy of ultrasonography for detection of proper ETT placement.
MATERIALS AND METHODS: This prospective study was carried out in the emergency department from February to October 2012. The ultrasonography was performed by a trained senior resident in two phases: (a) as the intubation was being performed (dynamic phase) and (b) after the intubation had been completed (static phase). A linear probe was placed transversely over the cricothyroid membrane during the intubation process (dynamic phase) and on the anterior neck just superior to the suprasternal notch in the static method. Operating characteristics were calculated for both dynamic and static determination of ETT placement.
RESULTS: Sixty patients were enrolled in each study group. The sensitivity, specificity, positive predictive value, and negative predictive value of the dynamic technique for determining correct endotracheal intubation were 98.1% [95% confidence interval (CI), 88.8-99.9%], 100% (95% CI, 51.6-100%), 100% (95% CI, 91.5-100%), and 85.7% (95% CI, 42-99.2%), respectively. Using the static technique, all testing characteristics listed previously were 100%.
CONCLUSION: In this study, we found acceptable sensitivity, specificity, positive predictive value, and negative predictive value for prediction of tracheal ETT placement with the use of dynamic and static ultrasonography.

Entities:  

Mesh:

Year:  2015        PMID: 24441884     DOI: 10.1097/MEJ.0000000000000108

Source DB:  PubMed          Journal:  Eur J Emerg Med        ISSN: 0969-9546            Impact factor:   2.799


  10 in total

1.  Improvement in Validity and Reliability of Airway Assessment Using Ultrasonography by Novice Personnel: A Learning Cohort Study.

Authors:  Sumidtra Prathep; Pawarit Sikarettrakul; Sasikaan Nimmaanrat; Wipharat Juthasantikul; Orarat Karnjanawanichkul; Nalinee Kovitwanawong
Journal:  Adv Med Educ Pract       Date:  2022-09-22

Review 2.  The Role of Airway and Endobronchial Ultrasound in Perioperative Medicine.

Authors:  Jiri Votruba; Petra Zemanová; Lukas Lambert; Michaela Michalkova Vesela
Journal:  Biomed Res Int       Date:  2015-12-14       Impact factor: 3.411

3.  Predictive Value of Tracheal Rapid Ultrasound Exam Performed in the Emergency Department for Verification of Tracheal Intubation.

Authors:  Babak Masoumi; Reza Azizkhani; Gilava Hedayati Emam; Morteza Asgarzadeh; Behrouz Zargar Kharazi
Journal:  Open Access Maced J Med Sci       Date:  2017-06-17

4.  Reliability of Ultrasonography in Confirming Endotracheal Tube Placement in an Emergency Setting.

Authors:  Vimal Koshy Thomas; Cherish Paul; Punchalil Chathappan Rajeev; Babu Urumese Palatty
Journal:  Indian J Crit Care Med       Date:  2017-05

5.  Rapidity and efficacy of ultrasonographic sliding lung sign and auscultation in confirming endotracheal intubation in overweight and obese patients.

Authors:  Sunil Rajan; Jayasankar Surendran; Jerry Paul; Lakshmi Kumar
Journal:  Indian J Anaesth       Date:  2017-03

Review 6.  Screening Performance Characteristics of Ultrasonography in Confirmation of Endotracheal Intubation; a Systematic Review and Meta-analysis.

Authors:  Mehrdad Farrokhi; Bardia Yarmohammadi; Amir Mangouri; Yasaman Hekmatnia; Yaser Bahramvand; Moein Kiani; Elham Nasrollahi; Milad Nazari-Sabet; Niusha Manoochehri-Arash; Maria Khurshid; Shima Mosalanejad; Vida Hajizadeh; Reza Amani-Beni; Masoumeh Moallem; Maryam Farahmandsadr
Journal:  Arch Acad Emerg Med       Date:  2021-10-26

7.  Diagnostic Accuracy of Suprasternal Versus Subxiphoid Ultrasonography for Endotracheal Intubation.

Authors:  Seyed Mohammad Mousavi; Maryam Sayyari Doughabadi; Seyed Ali Alamdaran; Sayyed Majid Sadrzadeh; Hosein Zakeri; Elnaz VafadarMoradi
Journal:  Anesth Pain Med       Date:  2022-03-13

8.  Tactile Method in Confirming Proper Endotracheal Intubation in Emergency Setting; a Letter to Editor.

Authors:  Behrang Rezvani Kakhki; Mohsen Miri; Morteza Talebi Doluee; Zeynab Sabeti Baygi; Zahra Abbasi Shaye; Elnaz Vafadar Moradi
Journal:  Arch Acad Emerg Med       Date:  2021-05-09

9.  Defining the learning curve of point-of-care ultrasound for confirming endotracheal tube placement by emergency physicians.

Authors:  Jordan Chenkin; Colin J L McCartney; Tomislav Jelic; Michael Romano; Claire Heslop; Glen Bandiera
Journal:  Crit Ultrasound J       Date:  2015-09-17

10.  Sensitivity and Specificity of a Novel Approach to Confirm the Depth of the Endotracheal Tube: A Pilot Study.

Authors:  Yansong Li; Ying Xie; Bailong Hu; Jing Wang; Haibo Song; Xinchuan Wei
Journal:  Medicine (Baltimore)       Date:  2015-08       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.