Literature DB >> 24418284

Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?

Hiroto Takahashi1, Masahiro Okada1, Tomoko Hyodo1, Syojiro Hidaka1, Yuki Kagawa1, Mitsuru Matsuki1, Masakatsu Tsurusaki1, Takamichi Murakami2.   

Abstract

PURPOSE: To investigate whether low-dose dynamic CT of the liver with iterative reconstruction can reduce both the radiation dose and the amount of contrast medium.
MATERIALS AND METHODS: This study was approved by our institutional review board. 113 patients were randomly assigned to one of two groups. Group A/group B (fifty-eight/fifty-five patients) underwent liver dynamic CT at 120/100 kV, with 0/40% adaptive statistical iterative reconstruction (ASIR), with a contrast dose of 600/480 mg I/kg, respectively. Radiation exposure was estimated based on the manufacturer's phantom data. The enhancement value of the hepatic parenchyma, vessels and the tumor-to-liver contrast of hepatocellular carcinomas (HCCs) were compared between two groups. Two readers independently assessed the CT images of the hepatic parenchyma and HCCs.
RESULTS: The mean CT dose indices: 6.38/4.04 mGy, the dose-length products: 194.54/124.57 mGy cm, for group A/group B. The mean enhancement value of the hepatic parenchyma and the tumor-to-liver contrast of HCCs with diameters greater than 1cm in the post-contrast all phases did not differ significantly between two groups (P>0.05). The enhancement values of vessels in group B were significantly higher than that in group A in the delayed phases (P<0.05). Two reader's confidence levels for the hepatic parenchyma in the delayed phases and HCCs did not differ significantly between the groups (P>0.05).
CONCLUSIONS: Low-dose dynamic CT with ASIR can reduce both the radiation dose and the amount of contrast medium without image quality degradation, compared to conventional dynamic CT without ASIR.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Contrast medium; Iterative reconstruction; Liver dynamic CT study; Low-dose CT

Mesh:

Substances:

Year:  2013        PMID: 24418284     DOI: 10.1016/j.ejrad.2013.12.014

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  10 in total

Review 1.  2018 Korean Liver Cancer Association-National Cancer Center Korea Practice Guidelines for the Management of Hepatocellular Carcinoma.

Authors: 
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

2.  2018 Korean Liver Cancer Association-National Cancer Center Korea Practice Guidelines for the Management of Hepatocellular Carcinoma.

Authors: 
Journal:  Gut Liver       Date:  2019-05-15       Impact factor: 4.519

3.  Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

Authors:  Yasunori Nagayama; Shota Tanoue; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Eri Yoshida; Morikatsu Yoshida; Masafumi Kidoh; Machiko Tateishi; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2018-03-02       Impact factor: 3.039

4.  Iodine load reduction in dual-energy spectral CT portal venography with low energy images combined with adaptive statistical iterative reconstruction.

Authors:  Dong Han; Xiaoxia Chen; Yuxin Lei; Chunling Ma; Jieli Zhou; Yingcong Xiao; Yong Yu
Journal:  Br J Radiol       Date:  2019-07-10       Impact factor: 3.039

5.  Possible Contrast Media Reduction with Low keV Monoenergetic Images in the Detection of Focal Liver Lesions: A Dual-Energy CT Animal Study.

Authors:  Yong Eun Chung; Je Sung You; Hye-Jeong Lee; Joon Seok Lim; Hye Sun Lee; Song-Ee Baek; Myeong-Jin Kim
Journal:  PLoS One       Date:  2015-07-23       Impact factor: 3.240

6.  Preoperative Assessment of Hepatocellular Carcinoma with Split-Bolus Combined Phase Contrast-Enhanced Computed Tomography.

Authors:  Jian Jiang; Ke Wang; Yufeng Xu; Jianxin Liu; Jingjing Luo; Xin Tao; Xiaoying Wang
Journal:  Med Sci Monit       Date:  2017-04-16

7.  Artificial Intelligence-Aided Diagnosis Software to Identify Highly Suspicious Pulmonary Nodules.

Authors:  Jun Lv; Jianhui Li; Yanzhen Liu; Hong Zhang; Xiangfeng Luo; Min Ren; Yufan Gao; Yanhe Ma; Shuo Liang; Yapeng Yang; Zhenchun Song; Guangming Gao; Guozheng Gao; Yusheng Jiang; Ximing Li
Journal:  Front Oncol       Date:  2022-02-15       Impact factor: 6.244

8.  Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality.

Authors:  Xiuli Zhang; Shaodong Li; Wenlou Liu; Ning Huang; Jingjing Li; Li Cheng; Kai Xu
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889

9.  Reduction of the radiation dose and the amount of contrast material in hepatic dynamic CT using low tube voltage and adaptive iterative dose reduction 3-dimensional.

Authors:  Atsushi Nakamoto; Kiyohito Yamamoto; Makoto Sakane; Go Nakai; Akira Higashiyama; Hiroshi Juri; Shushi Yoshikawa; Yoshifumi Narumi
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

10.  Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging.

Authors:  Xiao-Ping Yin; Bu-Lang Gao; Cai-Ying Li; Huan Zhou; Liang Zhao; Ya-Ting Zheng; Yong-Xia Zhao
Journal:  Korean J Radiol       Date:  2018-06-14       Impact factor: 3.500

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.