| Literature DB >> 29962864 |
Xiao-Ping Yin1, Bu-Lang Gao2, Cai-Ying Li3, Huan Zhou1, Liang Zhao1, Ya-Ting Zheng1, Yong-Xia Zhao1.
Abstract
Objective: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. Materials andEntities:
Keywords: CT angiography; Image optimization; Liver; Monochromatic image; Spectral CT
Mesh:
Year: 2018 PMID: 29962864 PMCID: PMC6005939 DOI: 10.3348/kjr.2018.19.4.578
Source DB: PubMed Journal: Korean J Radiol ISSN: 1229-6929 Impact factor: 3.500
Comparison of Hepatic Artery under Monochromatic and Hybrid Spectrum
| Image | CT Value | IN | CNR | SNR | Score |
|---|---|---|---|---|---|
| Optimal keV | 546 ± 97 | 38.0 ± 18.2 | 24.6 ± 10.9 | 28.3 ± 12.3 | 4.7 ± 0.2 |
| QC | 243 ± 45* | 21.5 ± 10.1* | 11.6 ± 4.6* | 15.4 ± 5.7* | 3.6 ± 0.4* |
| 70 keV | 287 ± 49.7*† | 21.0 ± 9.8* | 18.1 ± 8.3*† | 23.2 ± 10.3*† | 4.0 ± 0.3*† |
| < 0.001 | < 0.001 | < 0.001 | < 0.001 | < 0.001 |
Data shows mean ± SD. *p < 0.001 compared with optimal keV group, †p < 0.001 compared with QC group. CNR = contrast-to-noise ratio, CT = computed tomography, IN = image noise, SD = standard deviation, SNR = signal-to-noise ratio, QC = quality check
Comparison of Portal Vein under Monochromatic and Hybrid Spectrum
| Image | CT Value | IN | CNR | SNR | Score |
|---|---|---|---|---|---|
| Optimal keV | 293 ± 45 | 27.4 ± 11.0 | 6.9 ± 2.7 | 17.6 ± 5.7 | 4.5 ± 0.3 |
| QC | 140 ± 19* | 19.9 ± 5.6* | 3.0 ± 2.1* | 7.7 ± 4.8* | 3.3 ± 0.3* |
| 70 keV | 161 ± 23*† | 16.8 ± 6.6* | 4.3 ± 1.9*† | 10.9 ± 3.9*† | 3.9 ± 0.4*† |
| < 0.001 | < 0.001 | < 0.001 | < 0.001 | < 0.001 |
Data shows mean ± SD. *p < 0.01 compared with optimal keV group, †p < 0.01 compared with QC group.
Comparison of Hepatic Vein under Monochromatic and Hybrid Spectrum
| Images | CT Value | IN | CNR | SNR | Score |
|---|---|---|---|---|---|
| Optimal keV | 281 ± 49 | 24.7 ± 9.2 | 5.7 ± 2.3 | 14.9 ± 4.9 | 4.3 ± 0.4 |
| QC | 142 ± 20* | 19.1 ± 6.2* | 2.7 ± 1.4* | 9.5 ± 3.9* | 3.2 ± 0.3* |
| 70 keV | 165 ± 25*† | 14.4 ± 5.2* | 4.2 ± 1.9*† | 13.9 ± 4.8† | 3.8 ± 0.4*† |
| < 0.001 | < 0.001 | < 0.001 | < 0.001 | < 0.001 |
Data shows mean ± SD. *p < 0.01 compared with optimal keV group, †p < 0.01 compared with QC group.
Fig. 1Comparison of images.
In phase of hepatic artery in QC (A1), in 50 keV (B1), and in 70 keV (C1). In phase of portal vein for QC (A2), in 50 keV (B2), and in 70 keV (C2). In phase of hepatic vein in QC (A3), in 50 keV (B3), and in 70 keV (C3). QC = quality check