Literature DB >> 24418204

Root stabilization of the repaired bicuspid aortic valve: subcommissural annuloplasty versus root reimplantation.

Prashanth Vallabhajosyula1, Caroline Komlo1, Wilson Y Szeto1, Tyler J Wallen1, Nimesh Desai1, Joseph E Bavaria2.   

Abstract

BACKGROUND: At our institution, type I bicuspid aortic valve (BAV) patients with aortic insufficiency (AI) who are candidates for valve preservation are stratified into two groups by aortic root pathology: nonaneurysmal root undergoing primary cusp repair+subcommissural annuloplasty (repair group) vs aneurysmal root undergoing primary cusp repair+root reimplantation (reimplantation group). We report outcomes of this surgical reconstructive strategy for the repaired type I BAV.
METHODS: A retrospective review was performed of 71 patients with a type I BAV undergoing primary valve repair from 2005 to 2012. The repair group (n=40) underwent annular stabilization by subcommissural annuloplasty, and the reimplantation group (n=31) underwent robust annular stabilization provided by root reimplantation.
RESULTS: Preoperative characteristics and root anatomy were similar, except for increased root dimensions in the reimplantation group (p<0.001). Mortality, stroke, valve reoperation, and pacemaker requirement were zero in both groups. Postoperative peak (19±10 vs 11±5 mm Hg, p<0.001) and mean gradients (10±5 vs 5±3 mm Hg, p<0.001) favored root reimplantation. Freedom from AI greater than 1+ was 100% in both groups. Mean follow-up was 40 months in the reimplantation group and 38 months in the repair group. At 5 years, overall survival was 100% in both groups. Freedom from aortic reoperation and AI exceeding 2+ were similar in both groups. Freedom from AI exceeding 1+ was significantly better in the reimplantation group (92%±6% vs 62%±10%, p=0.03). The 2-year peak (14±6 vs 19±9 mm Hg, p=0.009) and mean (7±4 vs 11±5 mm Hg, p=0.001) gradients favored root reimplantation.
CONCLUSIONS: Root stabilization with the reimplantation technique significantly improves the durability of the repaired type I BAV compared with subcommissural annuloplasty. It also provides improved and sustained valve mobility (transvalvular gradients).
Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24418204     DOI: 10.1016/j.athoracsur.2013.10.071

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

Review 1.  Can the bicuspid aortic valve be spared? The con position, with caveats and nuances.

Authors:  Joseph E Bavaria; Caroline M Komlo; Tyler Rhode; Prashanth Vallabhajosyula
Journal:  Tex Heart Inst J       Date:  2013

Review 2.  Current topics on bicuspid aortic valve: clinical aspects and surgical management.

Authors:  Hiroshi Furukawa; Kazuo Tanemoto
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-06-19       Impact factor: 1.520

Review 3.  Aortic valve repair update.

Authors:  Tatsuhiko Komiya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-02-05

4.  The American Association for Thoracic Surgery consensus guidelines on bicuspid aortic valve-related aortopathy: Full online-only version.

Authors:  Michael A Borger; Paul W M Fedak; Elizabeth H Stephens; Thomas G Gleason; Evaldas Girdauskas; John S Ikonomidis; Ali Khoynezhad; Samuel C Siu; Subodh Verma; Michael D Hope; Duke E Cameron; Donald F Hammer; Joseph S Coselli; Marc R Moon; Thoralf M Sundt; Alex J Barker; Michael Markl; Alessandro Della Corte; Hector I Michelena; John A Elefteriades
Journal:  J Thorac Cardiovasc Surg       Date:  2018-08       Impact factor: 5.209

5.  Bicuspid aortic valve disease: systematic review and meta-analysis of surgical aortic valve repair.

Authors:  Maximilian Salcher; Huseyin Naci; Sarah Pender; Titus Kuehne; Marcus Kelm
Journal:  Open Heart       Date:  2016-12-16

6.  Bicuspid aortic valve repair using geometric ring annuloplasty: A first-in-humans pilot trial.

Authors:  J Scott Rankin; Domenico Mazzitelli; Theodor J M Fischlein; Yeong-Hoon Choi; Diana Aicher; Lawrence M Wei; Vinay Badhwar
Journal:  JTCVS Tech       Date:  2020-01-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.