Literature DB >> 24418154

Evaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials.

Mohammad Kia1, Antonis P Stylianou2, Trent M Guess3.   

Abstract

Knowledge of the forces acting on musculoskeletal joint tissues during movement benefits tissue engineering, artificial joint replacement, and our understanding of ligament and cartilage injury. Computational models can be used to predict these internal forces, but musculoskeletal models that simultaneously calculate muscle force and the resulting loading on joint structures are rare. This study used publicly available gait, skeletal geometry, and instrumented prosthetic knee loading data [1] to evaluate muscle driven forward dynamics simulations of walking. Inputs to the simulation were measured kinematics and outputs included muscle, ground reaction, ligament, and joint contact forces. A full body musculoskeletal model with subject specific lower extremity geometries was developed in the multibody framework. A compliant contact was defined between the prosthetic femoral component and tibia insert geometries. Ligament structures were modeled with a nonlinear force-strain relationship. The model included 45 muscles on the right lower leg. During forward dynamics simulations a feedback control scheme calculated muscle forces using the error signal between the current muscle lengths and the lengths recorded during inverse kinematics simulations. Predicted tibio-femoral contact force, ground reaction forces, and muscle forces were compared to experimental measurements for six different gait trials using three different gait types (normal, trunk sway, and medial thrust). The mean average deviation (MAD) and root mean square deviation (RMSD) over one gait cycle are reported. The muscle driven forward dynamics simulations were computationally efficient and consistently reproduced the inverse kinematics motion. The forward simulations also predicted total knee contact forces (166N<MAD<404N, 212N<RMSD<448N) and vertical ground reaction forces (66N<MAD<90N, 97N<RMSD<128N) well within 28% and 16% of experimental loads, respectively. However the simplified muscle length feedback control scheme did not realistically represent physiological motor control patterns during gait. Consequently, the simulations did not accurately predict medial/lateral tibio-femoral force distribution and muscle activation timing.
Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Gait; Multibody model; Musculoskeletal model; Prosthetic knee

Mesh:

Year:  2014        PMID: 24418154      PMCID: PMC4598057          DOI: 10.1016/j.medengphy.2013.12.007

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  33 in total

1.  Modelling, simulation and optimisation of a human vertical jump.

Authors:  T Spägele; A Kistner; A Gollhofer
Journal:  J Biomech       Date:  1999-05       Impact factor: 2.712

2.  Verification of predicted knee replacement kinematics during simulated gait in the Kansas knee simulator.

Authors:  Jason P Halloran; Chadd W Clary; Lorin P Maletsky; Mark Taylor; Anthony J Petrella; Paul J Rullkoetter
Journal:  J Biomech Eng       Date:  2010-08       Impact factor: 2.097

3.  Computational modelling of a total knee prosthetic loaded in a dynamic knee simulator.

Authors:  Trent M Guess; Lorin P Maletsky
Journal:  Med Eng Phys       Date:  2005-06       Impact factor: 2.242

4.  Knee joint biomechanics in open-kinetic-chain flexion exercises.

Authors:  W Mesfar; A Shirazi-Adl
Journal:  Clin Biomech (Bristol, Avon)       Date:  2008-01-04       Impact factor: 2.063

5.  ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months.

Authors:  Bernd Heinlein; Ines Kutzner; Friedmar Graichen; Alwina Bender; Antonius Rohlmann; Andreas M Halder; Alexander Beier; Georg Bergmann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2009-03-13       Impact factor: 2.063

6.  A computer model with surface friction for the prediction of total knee kinematics.

Authors:  S Sathasivam; P S Walker
Journal:  J Biomech       Date:  1997-02       Impact factor: 2.712

7.  The mechanics of the knee joint in relation to normal walking.

Authors:  J B Morrison
Journal:  J Biomech       Date:  1970-01       Impact factor: 2.712

8.  A multibody knee model with discrete cartilage prediction of tibio-femoral contact mechanics.

Authors:  Trent M Guess; Hongzeng Liu; Sampath Bhashyam; Ganesh Thiagarajan
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-10-04       Impact factor: 1.763

9.  The influence of patella alta on patellofemoral joint stress during normal and fast walking.

Authors:  Samuel R Ward; Christopher M Powers
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-12       Impact factor: 2.063

10.  Predicting the effects of muscle activation on knee, thigh, and hip injuries in frontal crashes using a finite-element model with muscle forces from subject testing and musculoskeletal modeling.

Authors:  Chia-Yuan Chang; Jonathan D Rupp; Matthew P Reed; Richard E Hughes; Lawrence W Schneider
Journal:  Stapp Car Crash J       Date:  2009-11
View more
  6 in total

1.  Predicted loading on the menisci during gait: The effect of horn laxity.

Authors:  Trent M Guess; Swithin Razu; Hamidreza Jahandar; Antonis Stylianou
Journal:  J Biomech       Date:  2015-03-14       Impact factor: 2.712

2.  Electromyography-Driven Forward Dynamics Simulation to Estimate In Vivo Joint Contact Forces During Normal, Smooth, and Bouncy Gaits.

Authors:  Swithin S Razu; Trent M Guess
Journal:  J Biomech Eng       Date:  2018-07-01       Impact factor: 2.097

3.  Computer simulation of lumbar flexion shows shear of the facet capsular ligament.

Authors:  Amy A Claeson; Victor H Barocas
Journal:  Spine J       Date:  2016-08-09       Impact factor: 4.166

4.  Muscle Synergies Facilitate Computational Prediction of Subject-Specific Walking Motions.

Authors:  Andrew J Meyer; Ilan Eskinazi; Jennifer N Jackson; Anil V Rao; Carolynn Patten; Benjamin J Fregly
Journal:  Front Bioeng Biotechnol       Date:  2016-10-13

5.  Musculoskeletal Model Development of the Elbow Joint with an Experimental Evaluation.

Authors:  Munsur Rahman; Mohsen Sharifi Renani; Akin Cil; Antonis P Stylianou
Journal:  Bioengineering (Basel)       Date:  2018-04-20

6.  Influences of load carriage and physical activity history on tibia bone strain.

Authors:  Henry Wang; Mohammad Kia; D Clark Dickin
Journal:  J Sport Health Sci       Date:  2016-11-09       Impact factor: 7.179

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.