Literature DB >> 25814179

Predicted loading on the menisci during gait: The effect of horn laxity.

Trent M Guess1, Swithin Razu2, Hamidreza Jahandar2, Antonis Stylianou3.   

Abstract

Radiographic measurements have established a link between meniscus extrusion and meniscus degeneration as well as with knee osteoarthritis. The presented work combines medical imaging with motion capture data from two healthy female subjects to create subject specific knee models that predict tibio-menisco-femoral contact forces and ligament forces during muscle driven simulations of barefoot gait. The developed computational models were used to explore the relationship between the extent of meniscal extrusion and biomechanical function by altering the laxity of the meniscal horn attachments during gait. The extrusion distance increased as laxity increased and the amount of contact force transferred through the menisci during gait decreased rapidly as the meniscal attachments became more lax. Horn attachment lengths that were 20% longer than MRI attachment lengths resulted in an almost complete loss of force transfer through the menisci during the gait cycle. Relatively small changes (2-3mm) in the lengths at which horn bundles first become taut, manifested in large changes in the capacity of the tissue to transmit forces. As meniscal horn attachment laxity increased from 80% to 120% of the MRI measured horn distance, medial meniscus extrusion increased 3.9mm for the first subject and 2.7mm for the second subject. For the same horn laxity changes, the percent of medial tibiofemoral contact force transmitted through the medial meniscus during early stance decreased from 51% to 8% and from 36% to 14% for the two subjects. The results of our study show that increased meniscal extrusion occurs with increased laxity of the meniscal tibia attachments and this increased laxity results in loss of meniscal function.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Computational biomechanics; Gait; Knee; Meniscal extrusion; Menisci; Musculoskeletal model

Mesh:

Year:  2015        PMID: 25814179      PMCID: PMC4442067          DOI: 10.1016/j.jbiomech.2015.01.047

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  61 in total

1.  Anatomic characteristics and radiographic references of the anterolateral and posteromedial bundles of the posterior cruciate ligament.

Authors:  Michael Osti; Peter Tschann; Karl Heinz Künzel; Karl Peter Benedetto
Journal:  Am J Sports Med       Date:  2012-04-26       Impact factor: 6.202

2.  The reproducibility of radiographic measurement of medial meniscus horn position.

Authors:  Philippe Wilmes; Konstantinos Anagnostakos; Christian Weth; Dieter Kohn; Romain Seil
Journal:  Arthroscopy       Date:  2008-06       Impact factor: 4.772

3.  The relationship between the medial collateral ligament and the medial meniscus: a topographical and biomechanical study.

Authors:  Gregor Stein; Juergen Koebke; Christoph Faymonville; Jens Dargel; Lars Peter Müller; Gereon Schiffer
Journal:  Surg Radiol Anat       Date:  2011-04-19       Impact factor: 1.246

4.  In-vitro measurement of static pressure distribution in synovial joints--Part I: Tibial surface of the knee.

Authors:  A M Ahmed; D L Burke
Journal:  J Biomech Eng       Date:  1983-08       Impact factor: 2.097

5.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

6.  Loading of the knee during 3.0T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis.

Authors:  Christoph Stehling; Richard B Souza; Marie-Pierre Hellio Le Graverand; Bradley T Wyman; Xiaojuan Li; Sharmila Majumdar; Thomas M Link
Journal:  Eur J Radiol       Date:  2012-08       Impact factor: 3.528

7.  From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments.

Authors:  Adam C Abraham; Tammy L Haut Donahue
Journal:  Acta Biomater       Date:  2013-02-04       Impact factor: 8.947

8.  MR imaging of the knee: position related changes of the menisci in asymptomatic volunteers.

Authors:  Larissa Boxheimer; Amelie M Lutz; Karl Treiber; Kerstin Goepfert; David W Crook; Borut Marincek; Dominik Weishaupt
Journal:  Invest Radiol       Date:  2004-05       Impact factor: 6.016

9.  Patient-specific knee joint finite element model validation with high-accuracy kinematics from biplane dynamic Roentgen stereogrammetric analysis.

Authors:  G Papaioannou; G Nianios; C Mitrogiannis; D Fyhrie; S Tashman; K H Yang
Journal:  J Biomech       Date:  2008-08-28       Impact factor: 2.712

10.  Meniscal tear and extrusion are strongly associated with progression of symptomatic knee osteoarthritis as assessed by quantitative magnetic resonance imaging.

Authors:  M-J Berthiaume; J-P Raynauld; J Martel-Pelletier; F Labonté; G Beaudoin; D A Bloch; D Choquette; B Haraoui; R D Altman; M Hochberg; J M Meyer; G A Cline; J-P Pelletier
Journal:  Ann Rheum Dis       Date:  2004-09-16       Impact factor: 19.103

View more
  5 in total

1.  Loading of the medial meniscus in the ACL deficient knee: A multibody computational study.

Authors:  Trent M Guess; Swithin Razu
Journal:  Med Eng Phys       Date:  2017-01-11       Impact factor: 2.242

2.  Mechanisms of energy dissipation and relationship with tissue composition in human meniscus.

Authors:  A Morejon; A M A Mantero; T M Best; A R Jackson; F Travascio
Journal:  Osteoarthritis Cartilage       Date:  2022-01-13       Impact factor: 6.576

3.  Alignment factors affecting the medial meniscus extrusion increases the risk of osteoarthritis development.

Authors:  Norio Goto; Ken Okazaki; Takenori Akiyama; Yukio Akasaki; Hideki Mizu-Uchi; Satoshi Hamai; Shunsuke Nakamura; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-11-19       Impact factor: 4.342

4.  Cartilage defect location and stiffness predispose the tibiofemoral joint to aberrant loading conditions during stance phase of gait.

Authors:  Lianne Zevenbergen; Colin R Smith; Sam Van Rossom; Darryl G Thelen; Nele Famaey; Jos Vander Sloten; Ilse Jonkers
Journal:  PLoS One       Date:  2018-10-16       Impact factor: 3.240

5.  Finite Element Modelling Simulated Meniscus Translocation and Deformation during Locomotion of the Equine Stifle.

Authors:  Pasquale Zellmann; Iris Ribitsch; Stephan Handschuh; Christian Peham
Journal:  Animals (Basel)       Date:  2019-07-31       Impact factor: 2.752

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.