Literature DB >> 24407551

Effect of selective enamel etching on clinical performance of CAD/CAM partial ceramic crowns luted with a self-adhesive resin cement.

Marianne Federlin1, Karl-Anton Hiller, Gottfried Schmalz.   

Abstract

OBJECTIVES: This study was conducted to evaluate a self-adhesive resin luting cement [RelyX Unicem 3MESPE-RXU] for luting partial ceramic crowns (PCCs) with and without selective enamel etching in a prospective, randomized clinical trial.
MATERIALS AND METHODS: Thirty-four patients had received the intended treatment. Two PCCs (Vita Mark II; Cerec 3D; Sirona) had been placed in a split-mouth design: one with RXU without enamel etching (RXU), the other with RXU with selective enamel etching (RXU + E). Restorations were evaluated at baseline (BL) and after 12, 24, and 36 months (USPHS criteria). For statistical analysis, the Chi-square test was applied (α = 0.05). Clinical survival of all restorations (n = 68) after 3 years was determined using Kaplan-Meier analysis.
RESULTS: Twenty three patients (12 male/11 female) were available for clinical evaluation after 3 years. 19 RXU-PCCs were placed in molars, four in premolars, 18 RXU + E-PCCs in molars, five in premolars. Concerning clinical changes, no significant differences were found between luting strategies RXU/RXU + E at all recalls. Statistically significant changes over time were observed for marginal adaptation and marginal discoloration between BL and 36 m for RXU and RXU + E. For RXU + E, postoperative hypersensitivities decreased significantly from BL (n = 6) to 36 m (n = 0). Of the 68 restorations originally included, eight RXU and four RXU + E restorations failed. At 3 years, Kaplan-Meier survival of RXU was 72.9 %, that of RXU + E 87.6 %. Survival rates were not statistically significant different.
CONCLUSIONS: Although clinical survival of RXU + E is slightly better at 3 years, restorations of both groups perform similar with respect to clinical changes over time as evaluated by modified USPHS criteria. CLINICAL RELEVANCE: The self-adhesive resin cement RXU can be used in conjunction with selective enamel etching, because survival rates of PCCs in the RXU + E group were not lower but, as a trend, even better than without enamel etching.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24407551     DOI: 10.1007/s00784-013-1173-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  41 in total

1.  IPS Empress inlays and onlays after four years--a clinical study.

Authors:  N Krämer; R Frankenberger; M Pelka; A Petschelt
Journal:  J Dent       Date:  1999-07       Impact factor: 4.379

2.  Technique sensitivity of dentin bonding: effect of application mistakes on bond strength and marginal adaptation.

Authors:  R Frankenberger; N Krämer; A Petschelt
Journal:  Oper Dent       Date:  2000 Jul-Aug       Impact factor: 2.440

3.  Partial ceramic crowns: influence of preparation design and luting material on internal adaptation.

Authors:  Marianne Federlin; Sebastian Schmidt; Karl-Anton Hiller; Birger Thonemann; Gottfried Schmalz
Journal:  Oper Dent       Date:  2004 Sep-Oct       Impact factor: 2.440

Review 4.  Self-adhesive resin cements - chemistry, properties and clinical considerations.

Authors:  J L Ferracane; J W Stansbury; F J T Burke
Journal:  J Oral Rehabil       Date:  2010-12-06       Impact factor: 3.837

5.  The analysis of restoration survival data in split-mouth designs.

Authors:  H Tobi; C M Kreulen; R J Gruythuysen; W E van Amerongen
Journal:  J Dent       Date:  1998-05       Impact factor: 4.379

6.  Short-term results of IPS-Empress inlays and onlays.

Authors:  S Studer; C Lehner; U Brodbeck; P Schärer
Journal:  J Prosthodont       Date:  1996-12       Impact factor: 2.752

7.  Clinical criteria.

Authors:  G Ryge
Journal:  Int Dent J       Date:  1980-12       Impact factor: 2.512

8.  Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. Results after 2 years.

Authors:  Frederike Schenke; Marianne Federlin; Karl-Anton Hiller; Daniel Moder; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2011-03-23       Impact factor: 3.573

9.  Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro.

Authors:  Marianne Federlin; Stephanie Krifka; Maximilian Herpich; Karl-Anton Hiller; Gottfried Schmalz
Journal:  Oper Dent       Date:  2007 May-Jun       Impact factor: 2.440

10.  [Motivation and education].

Authors:  U P Saxer; H R Mühlemann
Journal:  SSO Schweiz Monatsschr Zahnheilkd       Date:  1975-09
View more
  7 in total

1.  Controlled, prospective, randomized, clinical split-mouth evaluation of partial ceramic crowns luted with a new, universal adhesive system/resin cement: results after 18 months.

Authors:  Vanessa Vogl; Karl-Anton Hiller; Wolfgang Buchalla; Marianne Federlin; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2016-03-12       Impact factor: 3.573

2.  Polymer-infiltrated ceramic CAD/CAM inlays and partial coverage restorations: 3-year results of a prospective clinical study over 5 years.

Authors:  F A Spitznagel; K J Scholz; J R Strub; K Vach; P C Gierthmuehlen
Journal:  Clin Oral Investig       Date:  2017-12-06       Impact factor: 3.573

3.  Clinical survival of chair-side generated monolithic lithium disilicate crowns:10-year results.

Authors:  Angelika Rauch; Sven Reich; Luise Dalchau; Oliver Schierz
Journal:  Clin Oral Investig       Date:  2017-11-04       Impact factor: 3.573

Review 4.  Adhesive Systems Used in Indirect Restorations Cementation: Review of the Literature.

Authors:  Cristian Abad-Coronel; Belén Naranjo; Pamela Valdiviezo
Journal:  Dent J (Basel)       Date:  2019-07-01

5.  Prospective clinical evaluation of chairside-fabricated zirconia-reinforced lithium silicate ceramic partial crowns-5-year results.

Authors:  Sven Rinke; Tanja Zuck; Tim Hausdörfer; Andreas Leha; Torsten Wassmann; Dirk Ziebolz
Journal:  Clin Oral Investig       Date:  2021-08-20       Impact factor: 3.573

6.  Tooth surface treatment strategies for adhesive cementation.

Authors:  Nadja Rohr; Jens Fischer
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

7.  Evaluation of the clinical success of four different types of lithium disilicate ceramic restorations: a retrospective study.

Authors:  Sharo Abdulrahman; Constantin Von See Mahm; Ranjdar Talabani; Darwn Abdulateef
Journal:  BMC Oral Health       Date:  2021-12-07       Impact factor: 2.757

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.