Literature DB >> 15470879

Partial ceramic crowns: influence of preparation design and luting material on internal adaptation.

Marianne Federlin1, Sebastian Schmidt, Karl-Anton Hiller, Birger Thonemann, Gottfried Schmalz.   

Abstract

The influence of three different cavity preparations on the marginal integrity of partial ceramic crowns (PCC) luted with four different luting systems was investigated in this in vitro study. PCC preparations were performed in 144 extracted human molars using one of the following preparation designs (n=48/preparation): A--Coverage of functional cusps/butt joint preparation; B--horizontal reduction of functional cusps and C--complete reduction of functional cusps/butt joint preparation. Non-functional cusps were not covered; mesial and distal proximal boxes were extended 1 mm below the cemento-enamel-junction. PCC were fabricated from Vita Mark II ceramic (Vita) with a Cerec 3 Unit (Sirona) and adhesively luted to the cavities using the following luting systems: (VL) Variolink II/Excite (Vivadent), (PA) Panavia F/ED Primer (Kuraray), (DY) Dyract/Prime & Bond NT (DeTrey/Dentsply) and (FU) Fuji Plus/GC Cavity Conditioner (GC). Samples were simultaneously exposed to thermocycling and mechanical loading (TC: 5000x8-55 degrees C, 30 seconds/cycle; ML: 500000x72.5N, 1.6Hz). Marginal adaptation was assessed by evaluating dye penetration on multiple sections by relating the actual penetration distance to the maximal length of the corresponding cavity wall (100%). Ceramic- and tooth-luting material interfaces were evaluated separately. The data were statistically analyzed with the Mann Whitney U-test and Wilcoxon Rank Sumtest. In general, no significant differences could be found between preparations A, B and C. The combination of preparation C and luting material PA showed a tendency for the lowest dye penetration values, especially within dentin (30%). Significant differences could be determined between luting materials: Composite luting materials PA (0%) and VL (1%) revealed less dye penetration than the compomer DY (6%) and resin-modified glass ionomer cement (RMGIC) FU (26%); use of RMGIC caused fractures of the restorations. The dentin/luting material interface showed the highest penetration values, ranging from 17% to 100%. In conclusion, with adhesively bonded partial ceramic crowns, the choice of luting material proved to be more relevant than preparation design under the limitations of this study. Margins below the cemento-enamel junction reveal significant loss of adhesion in spite of subsequent application of adhesive luting techniques. RMGIC cannot be recommended as a luting material for feldspathic PCC.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15470879

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Influence of different cusp coverage methods for the extension of ceramic inlays on marginal integrity and enamel crack formation in vitro.

Authors:  Stephanie Krifka; Martin Stangl; Sarah Wiesbauer; Karl-Anton Hiller; Gottfried Schmalz; Marianne Federlin
Journal:  Clin Oral Investig       Date:  2009-01-10       Impact factor: 3.573

2.  Effect of selective enamel etching on clinical performance of CAD/CAM partial ceramic crowns luted with a self-adhesive resin cement.

Authors:  Marianne Federlin; Karl-Anton Hiller; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2014-01-10       Impact factor: 3.573

3.  Controlled, prospective, randomized, clinical split-mouth evaluation of partial ceramic crowns luted with a new, universal adhesive system/resin cement: results after 18 months.

Authors:  Vanessa Vogl; Karl-Anton Hiller; Wolfgang Buchalla; Marianne Federlin; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2016-03-12       Impact factor: 3.573

4.  Effect of seating forces on cement-ceramic adhesion in microtensile bond tests.

Authors:  Susana María Salazar Marocho; Mutlu Ozcan; Regina Amaral; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  Clin Oral Investig       Date:  2012-01-13       Impact factor: 3.573

Review 5.  Cementation of Glass-Ceramic Posterior Restorations: A Systematic Review.

Authors:  Carline R G van den Breemer; Marco M M Gresnigt; Marco S Cune
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.