Literature DB >> 24405567

An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb.

Brad J Farrell1, Boris I Prilutsky2, Robert S Kistenberg1, John F Dalton3, Mark Pitkin4.   

Abstract

BACKGROUND: Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking.
METHODS: Full-body mechanics of walking in two cats were recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading on the implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study.
FINDINGS: The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth.
INTERPRETATION: The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a bone-anchored prosthesis. Future studies with this model will help optimize the implant and prosthesis properties.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone-anchored prostheses; Histology; Osseointegration; Porous percutaneous titanium implant; Prosthetic gait; Skin–implant–bone interface

Mesh:

Substances:

Year:  2013        PMID: 24405567      PMCID: PMC3959271          DOI: 10.1016/j.clinbiomech.2013.12.014

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  69 in total

1.  Somatosensory control of balance during locomotion in decerebrated cat.

Authors:  Pavel Musienko; Gregoire Courtine; Jameson E Tibbs; Vyacheslav Kilimnik; Alexandr Savochin; Alan Garfinkel; Roland R Roy; V Reggie Edgerton; Yury Gerasimenko
Journal:  J Neurophysiol       Date:  2012-01-11       Impact factor: 2.714

2.  Socket versus bone-anchored trans-femoral prostheses: hip range of motion and sitting comfort.

Authors:  K Hagberg; E Häggström; M Uden; R Brånemark
Journal:  Prosthet Orthot Int       Date:  2005-08       Impact factor: 1.895

3.  Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses.

Authors:  Catherine J Pendegrass; Allen E Goodship; Gordon W Blunn
Journal:  Biomaterials       Date:  2006-04-17       Impact factor: 12.479

4.  Control of lateral balance in walking. Experimental findings in normal subjects and above-knee amputees.

Authors:  At L Hof; Renske M van Bockel; Tanneke Schoppen; Klaas Postema
Journal:  Gait Posture       Date:  2006-06-05       Impact factor: 2.840

5.  On the nature of the fundamental activity of the nervous centres; together with an analysis of the conditioning of rhythmic activity in progression, and a theory of the evolution of function in the nervous system.

Authors:  T G Brown
Journal:  J Physiol       Date:  1914-03-31       Impact factor: 5.182

6.  Sealing the skin barrier around transcutaneous implants: in vitro study of keratinocyte proliferation and adhesion in response to surface modifications of titanium alloy.

Authors:  C J Pendegrass; D Gordon; C A Middleton; S Ng Man Sun; G W Blunn
Journal:  J Bone Joint Surg Br       Date:  2008-01

7.  Load on osseointegrated fixation of a transfemoral amputee during a fall: loading, descent, impact and recovery analysis.

Authors:  Laurent Alain Frossard; Roy Tranberg; Eva Haggstrom; Mark Pearcy; Rickard Brånemark
Journal:  Prosthet Orthot Int       Date:  2010-03       Impact factor: 1.895

8.  Tissue reaction to soft-tissue anchored percutaneous implants in rabbits.

Authors:  J A Jansen; Y G Paquay; J P van der Waerden
Journal:  J Biomed Mater Res       Date:  1994-09

9.  Percutaneous implants with porous titanium dermal barriers: an in vivo evaluation of infection risk.

Authors:  Dorthyann Isackson; Lawrence D McGill; Kent N Bachus
Journal:  Med Eng Phys       Date:  2010-12-10       Impact factor: 2.242

10.  Walking ability and quality of life in subjects with transfemoral amputation: a comparison of osseointegration with socket prostheses.

Authors:  Hendrik Van de Meent; Maria T Hopman; Jan Paul Frölke
Journal:  Arch Phys Med Rehabil       Date:  2013-06-14       Impact factor: 3.966

View more
  7 in total

1.  Kinetics of individual limbs during level and slope walking with a unilateral transtibial bone-anchored prosthesis in the cat.

Authors:  Joshua R Jarrell; Brad J Farrell; Robert S Kistenberg; John F Dalton; Mark Pitkin; Boris I Prilutsky
Journal:  J Biomech       Date:  2018-05-23       Impact factor: 2.712

2.  Distraction Implantation. A New Technique in Total Joint Arthroplasty and Direct Skeletal Attachment.

Authors:  Mark Pitkin
Journal:  EC Orthop       Date:  2018-04-26

Review 3.  Recent Progress in Animal Studies of the Skin- and Bone-integrated Pylon With Deep Porosity for Bone-Anchored Limb Prosthetics With and Without Neural Interface.

Authors:  Mark Pitkin; Charles Cassidy; Maxim A Shevtsov; Joshua R Jarrell; Hangue Park; Brad J Farrell; John F Dalton; W Lee Childers; Robert S Kistenberg; Kyunggeune Oh; Alexander N Klishko; Boris I Prilutsky
Journal:  Mil Med       Date:  2021-01-25       Impact factor: 1.437

4.  A Prototype of a Neural, Powered, Transtibial Prosthesis for the Cat: Benchtop Characterization.

Authors:  Hangue Park; Muhammad S Islam; Martha A Grover; Alexander N Klishko; Boris I Prilutsky; Stephen P DeWeerth
Journal:  Front Neurosci       Date:  2018-07-13       Impact factor: 4.677

5.  Biomechanical Test of a New Endoprosthesis for Cylindrical Medullary Canals in Dogs.

Authors:  Rosa Mendaza-DeCal; Yolanda Ballesteros; Salvador Peso-Fernandez; Eva Paz; Juan Carlos Del Real-Romero; Jesus Rodriguez-Quiros
Journal:  Front Vet Sci       Date:  2022-06-30

6.  Protecting the skin-implant interface with transcutaneous silver-coated skin-and-bone-integrated pylon in pig and rabbit dorsum models.

Authors:  Maxim Shevtsov; Dmitriy Gavrilov; Natalia Yudintceva; Elena Zemtsova; Andrei Arbenin; Vladimir Smirnov; Irina Voronkina; Polina Adamova; Miralda Blinova; Nataliya Mikhailova; Oleg Galibin; Michael Akkaoui; Mark Pitkin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-09-16       Impact factor: 3.405

7.  Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model.

Authors:  Brian T Grisez; Andrew E Hanselman; Karim W Boukhemis; Trapper A J Lalli; Brock A Lindsey
Journal:  Adv Orthop       Date:  2018-09-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.