Literature DB >> 20196690

Load on osseointegrated fixation of a transfemoral amputee during a fall: loading, descent, impact and recovery analysis.

Laurent Alain Frossard1, Roy Tranberg, Eva Haggstrom, Mark Pearcy, Rickard Brånemark.   

Abstract

Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterize a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while attending a gait measurement session to assess the load applied on the residuum. The objective was to analyze the load applied on the fixation with an emphasis on the sequence of events, the pattern and the magnitude of the forces and moments. The load was measured directly at 200 Hz using a six-channel transducer. Complementary video footage was also studied. The fall was divided into four phases: Loading (240 ms), descent (620 ms), impact (365 ms) and recovery (2495 ms). The main impact forces and moments occurred 870 ms and 915 ms after the heel contact, and corresponded to 133% BW and 17 % BWm, or 1.2 and 11.2 times the maximum forces and moments applied during the previous steps of the participant, respectively. This study provided key information to engineers and clinicians facing the challenge to design equipment, and rehabilitation and exercise programs to restore safely the locomotion of lower limb amputees.

Entities:  

Mesh:

Year:  2010        PMID: 20196690     DOI: 10.3109/03093640903585024

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  10 in total

1.  New method of fixation of in-bone implanted prosthesis.

Authors:  Mark Pitkin; Charles Cassidy; Raghuveer Muppavarapu; James Raymond; Maxim Shevtsov; Oleg Galibin; Serge D Rousselle
Journal:  J Rehabil Res Dev       Date:  2013

2.  An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb.

Authors:  Brad J Farrell; Boris I Prilutsky; Robert S Kistenberg; John F Dalton; Mark Pitkin
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-12-23       Impact factor: 2.063

3.  [Function of prosthesis components in lower limb amputees with bone-anchored percutaneous implants : Biomechanical aspects].

Authors:  S Blumentritt
Journal:  Unfallchirurg       Date:  2017-05       Impact factor: 1.000

4.  Recording of electric signal passing through a pylon in direct skeletal attachment of leg prostheses with neuromuscular control.

Authors:  M Pitkin; C Cassidy; R Muppavarapu; D Edell
Journal:  IEEE Trans Biomed Eng       Date:  2012-02-13       Impact factor: 4.538

Review 5.  Design features of implants for direct skeletal attachment of limb prostheses.

Authors:  M Pitkin
Journal:  J Biomed Mater Res A       Date:  2013-04-02       Impact factor: 4.396

6.  Estimated forces and moments experienced by osseointegrated endoprostheses for lower extremity amputees.

Authors:  Carolyn E Taylor; Yue Zhang; Yuqing Qiu; Heath B Henninger; K Bo Foreman; Kent N Bachus
Journal:  Gait Posture       Date:  2020-05-20       Impact factor: 2.840

7.  Development of a Procedure for the Government Provision of Bone-Anchored Prosthesis Using Osseointegration in Australia.

Authors:  Laurent Frossard; Gregory Merlo; Tanya Quincey; Brendan Burkett; Debra Berg
Journal:  Pharmacoecon Open       Date:  2017-12

8.  Monitoring functional capability of individuals with lower limb amputations using mobile phones.

Authors:  Mark V Albert; Cliodhna McCarthy; Juliana Valentin; Megan Herrmann; Konrad Kording; Arun Jayaraman
Journal:  PLoS One       Date:  2013-06-04       Impact factor: 3.240

9.  The Evaluation of Daily Life Activities after Application of an Osseointegrated Prosthesis Fixation in a Bilateral Transfemoral Amputee: A Case Study.

Authors:  Stephanie A F Schalk; Niels Jonkergouw; Fred van der Meer; Willem M Swaan; Horst-H Aschoff; Peter van der Wurff
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

10.  Stiffness and ultimate load of osseointegrated prosthesis fixations in the upper and lower extremity.

Authors:  Bastian Welke; Christof Hurschler; Marie Föller; Michael Schwarze; Tilman Calliess
Journal:  Biomed Eng Online       Date:  2013-07-11       Impact factor: 2.819

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.