Literature DB >> 16048479

Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation.

Kenneth N Litwak1, Steven C Koenig, Rolando C Cheng, Guruprasad A Giridharan, Kevin J Gillars, George M Pantalos.   

Abstract

Although continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VADs) are being clinically used, their effects on aortic blood flow, as a measure of overall blood distribution, remain unclear. In acute VAD support animal experiments, our group has described a zone of turbulent mixing in the aortic arch. The objective of this study was to confirm this finding in the controlled setting of an adult mock circulation, simulating ventricular pathophysiologic states (normal and failing ventricle). CF and PF flow VADs were connected to ventricular apical inflow and ascending aorta (AA) or descending aorta (DA) outflow cannulae. Cardiovascular pressure and flow waveforms were recorded at varying levels of VAD bypass resulting in four test conditions: (i) CF-AA; (ii) CF-DA; (iii) PF-AA; and (iv) PF-DA. Confirming the animal data, no differences in mean aortic flow between CF and PF VADs were found, and significantly lower mean aortic arch flow with DA cannulation was noted. Mean aortic root flow decreased with increasing VAD bypass flow. As in the animal studies, despite similar mean flow rates, significant differences in waveform morphology were observed for AA and DA outflow graft locations and varying levels of VAD bypass. At 100% VAD support in the failing heart, PF restored waveform pulsatility to normal baseline while CF resulted in little pulsatility. These results confirm our earlier findings in the animal model, suggesting that outflow graft location may have a significant effect on aortic blood flow distribution. The long-term implications of these findings are being examined in ongoing studies.

Mesh:

Year:  2005        PMID: 16048479     DOI: 10.1111/j.1525-1594.2005.29100.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist.

Authors:  Guruprasad A Giridharan; Steven C Koenig; Jeffrey Kennington; Michael A Sobieski; Jun Chen; Steven H Frankel; Mark D Rodefeld
Journal:  J Thorac Cardiovasc Surg       Date:  2012-03-14       Impact factor: 5.209

2.  Early feasibility testing and engineering development of the transapical approach for the HeartWare MVAD ventricular assist system.

Authors:  Daniel Tamez; Jeffrey A LaRose; Charles Shambaugh; Katherine Chorpenning; Kevin G Soucy; Michael A Sobieski; Leslie Sherwood; Guruprasad A Giridharan; Gretel Monreal; Steven C Koenig; Mark S Slaughter
Journal:  ASAIO J       Date:  2014 Mar-Apr       Impact factor: 2.872

Review 3.  Miniaturization of mechanical circulatory support systems.

Authors:  Guruprasad A Giridharan; Thomas J Lee; Mickey Ising; Michael A Sobieski; Steven C Koenig; Laman A Gray; Mark S Slaughter
Journal:  Artif Organs       Date:  2012-08       Impact factor: 3.094

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.