Literature DB >> 24392429

A technique elucidating the retrieval of an adhered cover screw in a dental implant - a case report.

J Bhuvaneswarri1, S C Chandrasekaran2.   

Abstract

Dental implants have become one of the most popular and rapidly growing techniques for replacing missing teeth. While their predictability, functionality, and durability make them an attractive option for patients and clinicians alike, complications can arise at any stage from patient assessment to maintenance of therapy. Failure of dental implants not only occurs due to biological factors, like unsuccessful osseointegration or peri-implantitis but may also occur due to technical complications like, failures of implant-supported restorations relating those from the implant components, and those relating to the prosthesis. Technical problems related to implant components include abutment screw fractures and cover screw fractures. In this case report we have elucidated an adhered cover screw in an implant.

Entities:  

Keywords:  Cover screw; Dental Implant; Implant failure

Year:  2013        PMID: 24392429      PMCID: PMC3879871          DOI: 10.7860/JCDR/2013/6880.3637

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  7 in total

Review 1.  Implant prosthodontics: current perspective and future directions.

Authors:  T D Taylor; J R Agar; T Vogiatzi
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Jan-Feb       Impact factor: 2.804

2.  Retrieval technique for fractured implant screws.

Authors:  R T Williamson; F G Robinson
Journal:  J Prosthet Dent       Date:  2001-11       Impact factor: 3.426

Review 3.  Osseointegration: a reality.

Authors:  R K Schenk; D Buser
Journal:  Periodontol 2000       Date:  1998-06       Impact factor: 7.589

4.  Comparison of strength and failure mode of seven implant systems: an in vitro test.

Authors:  L Möllersten; P Lockowandt; L A Lindén
Journal:  J Prosthet Dent       Date:  1997-12       Impact factor: 3.426

5.  Fractured prosthetic abutments in osseointegrated implants: a technical complication to cope with.

Authors:  S Luterbacher; I Fourmousis; N P Lang; U Brägger
Journal:  Clin Oral Implants Res       Date:  2000-04       Impact factor: 5.977

6.  Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function.

Authors:  U Brägger; S Aeschlimann; W Bürgin; C H Hämmerle; N P Lang
Journal:  Clin Oral Implants Res       Date:  2001-02       Impact factor: 5.977

Review 7.  Fracture of dental implants: literature review and report of a case.

Authors:  Nirit Tagger Green; Eli E Machtei; Jacob Horwitz; Micha Peled
Journal:  Implant Dent       Date:  2002       Impact factor: 2.454

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.