Literature DB >> 11168207

Fractured prosthetic abutments in osseointegrated implants: a technical complication to cope with.

S Luterbacher1, I Fourmousis, N P Lang, U Brägger.   

Abstract

In the present report a repair set to retrieve fractured abutments remaining in the implants of the ITI Dental Implant System is presented. In 1 case in which such fractures occurred, the repair set was successfully applied. After removal of all particles of the fractured prosthetic abutments and recutting the threads, new abutments were used, and the original suprastructure could be reinserted. The causes for such technical failures are discussed considering the relatively sparse information in the literature on that topic.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11168207

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  9 in total

1.  A Simple and Cost Effective Method used for Removal of a Fractured Implant Abutment Screw: A Case Report.

Authors:  Parth Satwalekar; K Subash Chander; B Anantha Reddy; N Sandeep; N Sandeep; Tanushree Satwalekar
Journal:  J Int Oral Health       Date:  2013-10-26

2.  A technique elucidating the retrieval of an adhered cover screw in a dental implant - a case report.

Authors:  J Bhuvaneswarri; S C Chandrasekaran
Journal:  J Clin Diagn Res       Date:  2013-10-23

3.  Management of Broken Dental Implant Abutment in a Patient with Bruxism: A Rare Case Report and Review of Literature.

Authors:  Saad Al-Almaie
Journal:  Contemp Clin Dent       Date:  2017 Jul-Sep

Review 4.  Management of perishing implants with abutment screw fracture - A systematic review.

Authors:  Soja Raju; Vivek V Nair; Harsha Kumar Karunakaran; Noxy George Manjuran
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

5.  Salvage of fractured abutment screw by transfer cap screw replacement (original study).

Authors:  Rawaa Y Al-Rawee; Fatima A Mohammad; Bashar A Tawfeeq
Journal:  Clin Case Rep       Date:  2019-05-10

6.  Analysis of Torque Maintenance and Fracture Resistance after Fatigue in Retention Screws Made of Different Metals for Screw-Retained Implant-Borne Prosthesis Joints.

Authors:  Maria Beatriz Bello Taborda; Gabriela Sumie Yaguinuma Gonçalves; Cecília Alves de Sousa; Wirley Gonçalves Assunção
Journal:  Int J Dent       Date:  2021-11-18

Review 7.  Retrieval of Fractured Implant Abutment Screws: A Narrative Review.

Authors:  Prabhu Nayana; Sunil S Nayak; Abhirup Chatterjee; Karthik Sivaraman; Gadicherla Srikanth; Chhavi Singh
Journal:  J Int Soc Prev Community Dent       Date:  2022-06-29

8.  Noninvasive method for retrieval of broken dental implant abutment screw.

Authors:  Jagadish Reddy Gooty; Sunil Kumar Palakuru; Vikram Reddy Guntakalla; Mahipal Nera
Journal:  Contemp Clin Dent       Date:  2014-04

9.  Comparison of implant component fractures in external and internal type: A 12-year retrospective study.

Authors:  Yuseung Yi; Jai-Young Koak; Seong-Kyun Kim; Shin-Jae Lee; Seong-Joo Heo
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904