Literature DB >> 24390668

Elastography for the differentiation of benign and malignant liver lesions: a meta-analysis.

Xuelei Ma1, Wenli Zhan, Binglan Zhang, Benling Wei, Xin Wu, Min Zhou, Lei Liu, Ping Li.   

Abstract

The objective of this paper was to evaluate the overall accuracy of elastography in the diagnosis of benign and malignant liver lesions by liver biopsy as the gold standard. Literature databases were searched. The studies which were related to evaluate the diagnostic value of elastography for differentiation in benign and malignant liver lesions in English or Chinese were included. The summary receiver operating characteristic (SROC) curve was performed, and the areas under the curve (AUC) were also calculated to present the accuracy of the elastography for the diagnosis of benign and malignant liver lesions. Six studies which included a total of 448 liver lesions in 384 patients were analyzed. The summary sensitivity and specificity of elastography for the differentiation of malignant liver lesions were 85% (95% CI, 80 to 89%) and 84% (95% CI, 80 to 88%), respectively. And the summary diagnostic odds ratio was 46.33 (95% CI, 15.22 to 141.02), and the SROC was 0.9328. Elastography has a high sensitivity and specificity differentiation for benign and malignant liver lesions. As a non-invasive method, it is promising to be applied to clinical practice. To estimate elastography objectively, a large, prospective, international, and multi-center study is still needed.

Entities:  

Mesh:

Year:  2014        PMID: 24390668     DOI: 10.1007/s13277-013-1591-4

Source DB:  PubMed          Journal:  Tumour Biol        ISSN: 1010-4283


  36 in total

Review 1.  Focus on dysplastic nodules and early hepatocellular carcinoma: an Eastern point of view.

Authors:  Masamichi Kojiro
Journal:  Liver Transpl       Date:  2004-02       Impact factor: 5.799

2.  Real-time elastography for the differentiation of benign and malignant thyroid nodules: a meta-analysis.

Authors:  Jörg Bojunga; Eva Herrmann; Gesine Meyer; Sonja Weber; Stefan Zeuzem; Mireen Friedrich-Rust
Journal:  Thyroid       Date:  2010-10       Impact factor: 6.568

3.  Thyroid gland tumor diagnosis at US elastography.

Authors:  Andrej Lyshchik; Tatsuya Higashi; Ryo Asato; Shinzo Tanaka; Juichi Ito; Jerome J Mai; Claire Pellot-Barakat; Michael F Insana; Aaron B Brill; Tsuneo Saga; Masahiro Hiraoka; Kaori Togashi
Journal:  Radiology       Date:  2005-08-18       Impact factor: 11.105

4.  A method for characterization of tissue elastic properties combining ultrasonic computed tomography with elastography.

Authors:  Tanya Glozman; Haim Azhari
Journal:  J Ultrasound Med       Date:  2010-03       Impact factor: 2.153

Review 5.  Measuring the accuracy of diagnostic systems.

Authors:  J A Swets
Journal:  Science       Date:  1988-06-03       Impact factor: 47.728

6.  Operating characteristics of a rank correlation test for publication bias.

Authors:  C B Begg; M Mazumdar
Journal:  Biometrics       Date:  1994-12       Impact factor: 2.571

7.  Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations.

Authors:  L E Moses; D Shapiro; B Littenberg
Journal:  Stat Med       Date:  1993-07-30       Impact factor: 2.373

8.  Real-time elastography for the differentiation of benign and malignant superficial lymph nodes: a meta-analysis.

Authors:  Li Ying; Yao Hou; Hua-Min Zheng; Xiao Lin; Zuo-Liu Xie; Yuan-Ping Hu
Journal:  Eur J Radiol       Date:  2011-12-03       Impact factor: 3.528

9.  Usefulness of acoustic radiation force impulse imaging in the differential diagnosis of benign and malignant liver lesions.

Authors:  Tian Shuang-Ming; Zhou Ping; Qian Ying; Chen Li-Rong; Zhang Ping; Li Rui-Zhen
Journal:  Acad Radiol       Date:  2011-03-21       Impact factor: 3.173

10.  Utility of semiquantitative parameters to differentiate benign and malignant focal hepatic lesions.

Authors:  Banu Alicioglu; OmerTolga Guler; Nail Bulakbasi; Suha Akpinar; Ozgur Tosun; Cem Comunoglu
Journal:  Clin Imaging       Date:  2013-02-27       Impact factor: 1.605

View more
  4 in total

1.  Local curative effect of MRI-guided radiofrequency ablation on small hepatocellular carcinoma.

Authors:  Zheng-Yu Lin; Qian-Qian Song; Jin Chen; Ren-Jun Wan; Hui Zheng; Zhong-Wu Chen; Yi-Ping Chen; Wang-Chun Hua
Journal:  Tumour Biol       Date:  2014-12-14

2.  Application Value of Mass Spectrometry in the Differentiation of Benign and Malignant Liver Tumors.

Authors:  Bo Li; Boan Li; Tongsheng Guo; Zhiqiang Sun; Xiaohan Li; Xiaoxi Li; Han Wang; Weijiao Chen; Peng Chen; Mengran Qiao; Lifang Xia; Yuanli Mao
Journal:  Med Sci Monit       Date:  2017-04-04

3.  Role of EUS in detection of liver metastasis not seen by computed tomography or magnetic resonance imaging during staging of pancreatic, gastrointestinal, and thoracic malignancies.

Authors:  Hussein Hassan Okasha; Mohamed-Naguib Wifi; Abeer Awad; Yasmine Abdelfatah; Dalia Abdelfatah; Shereen Sadik El-Sawy; Ahmed Alzamzamy; Sameh Abou-Elenin; Amr Abou-Elmagd; Ramy ElHusseiny; Mahmoud Wahba; Mohamed A El-Feki; Katarzyna M Pawlak
Journal:  Endosc Ultrasound       Date:  2021 Sep-Oct       Impact factor: 5.628

Review 4.  Ultrasound Elastography: Review of Techniques and Clinical Applications.

Authors:  Rosa M S Sigrist; Joy Liau; Ahmed El Kaffas; Maria Cristina Chammas; Juergen K Willmann
Journal:  Theranostics       Date:  2017-03-07       Impact factor: 11.556

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.