Literature DB >> 24379864

The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements.

Atiyeh Feiz1, Behnaz Barekatain2, Roohollah Naseri3, Hossein Zarezadeh1, Navid Askari1, Saman Nasiri3.   

Abstract

BACKGROUND: Ultrasonic vibrations are used to remove a cemented post from a root canal requiring endodontic retreatment. Various results have been reported from the studies that evaluated the effect of ultrasonic instruments in removing the posts cemented with resin cements. The aim of this study was to evaluate the effect of ultrasonic energy on the retention of prefabricated metal post cemented with Panavia or Maxcem Elite cements.
MATERIALS AND METHODS: In this in vitro study, forty eight extracted single root premolars were decoronated with a diamond disc leaving a 13 mm long root and endodontically treated. The root canals were obturated by gutta-percha up to 5 mm with vertical condensation method and the 8 mm post-space was prepared to receive a no. 2 long Dentorama post. The roots were placed in an incubator for 48 h in 37°C and 100% humidity. After mounting the teeth in acrylic blocks, posts were cemented in the root canals using Panavia F2.0 in 24 specimens and Maxcem Elite in 24 others. For half of the specimens in each subgroup, an ultrasonic device was applied for 4 min. Universal testing machine was used to measure the force needed to remove the posts with a crosshead speed of 1 mm/min until the post came out of the canal. Kruskal-Wallis test was used for statistical analysis at 5% level of significance.
RESULTS: The removal force was not significantly different among the groups (P > 0.05).
CONCLUSION: Ultrasonic energy did not decrease the retention of posts cemented with Panavia or Maxcem Elite cements. Furthermore, it seems that there is no significant difference between removal force of self-etch (Panavia) and the self-etch self-adhesive (Maxcem Elite) resin cements.

Entities:  

Keywords:  Post removal; prefabricated metal post; resin cement; ultrasound

Year:  2013        PMID: 24379864      PMCID: PMC3872627     

Source DB:  PubMed          Journal:  Dent Res J (Isfahan)        ISSN: 1735-3327


  15 in total

1.  The influence of ultrasound on the retention of cast posts cemented with different agents.

Authors:  A P Gomes; C H Kubo; R A Santos; D R Santos; R Q Padilha
Journal:  Int Endod J       Date:  2001-03       Impact factor: 5.264

2.  Comparison of two ultrasonic instruments for post removal.

Authors:  Eric B Dixon; Peter J Kaczkowski; Jack I Nicholls; Gerald W Harrington
Journal:  J Endod       Date:  2002-02       Impact factor: 4.171

3.  Factors influencing the removal of posts.

Authors:  C H J Hauman; N P Chandler; D G Purton
Journal:  Int Endod J       Date:  2003-10       Impact factor: 5.264

4.  Influence of ultrasound, with and without water spray cooling, on removal of posts cemented with resin or zinc phosphate cements.

Authors:  Angela Delfina Bittencourt Garrido; Tabajara Sabbag Fonseca; Edson Alfredo; Yara Teresinha Corrêa Silva-Sousa; Manoel D Sousa-Neto
Journal:  J Endod       Date:  2004-03       Impact factor: 4.171

5.  Efficacy of ultrasound in removal of intraradicular posts using different techniques.

Authors:  Neilor Mateus Antunes Braga; Edson Alfredo; Luis Pascoal Vansan; Tabajara Sabbag Fonseca; José Antonio Brufato Ferraz; Manoel Damião Sousa-Neto
Journal:  J Oral Sci       Date:  2005-09       Impact factor: 1.556

6.  Comparison of the time required for removal of intraradicular cast posts using two Brazilian ultrasound devices.

Authors:  Manoel Brito; Janir Alves Soares; Suelleng Maria Cunha Santos; Carla Cristina Camilo; Gil Moreira
Journal:  Braz Oral Res       Date:  2009 Jan-Mar

7.  Removal of fractured posts using ultrasonic vibration: an in vivo study.

Authors:  B J Smith
Journal:  J Endod       Date:  2001-10       Impact factor: 4.171

8.  Evaluation of ultrasonic and sonic instruments for intraradicular post removal.

Authors:  J Buoncristiani; B G Seto; A A Caputo
Journal:  J Endod       Date:  1994-10       Impact factor: 4.171

9.  Influence of ultrasound, with and without water spray cooling, on removal of posts cemented with resin or glass ionomer cements: An in-vitro study.

Authors:  M S Adarsha; D A Lata
Journal:  J Conserv Dent       Date:  2010-07

10.  Influence of luting agents on time required for cast post removal by ultrasound: an in vitro study.

Authors:  Janir Alves Soares; Manoel Brito-Júnior; Dimitri Ribas Fonseca; Anielo Faleiro Melo; Suelleng Maria Cunha Santos; Nadia Del Carmen Soto Sotomayor; Neilor Mateus Antunes Braga; André Luis Faria e Silva
Journal:  J Appl Oral Sci       Date:  2009 May-Jun       Impact factor: 2.698

View more
  2 in total

1.  Influence of Glass Fiber Post Design and Luting Cements on Ease of Post Removal and Fracture Strength of Endodontically Retreated Teeth: An In Vitro Study.

Authors:  Prerna P Krishnarayan; Paras M Gehlot
Journal:  J Int Soc Prev Community Dent       Date:  2022-04-08

2.  Retention of Cast Posts Cemented with Two Commonly Used Conventional and Two Resin Cements and the Mode of Root Fracture Following Their Removal.

Authors:  Azadeh Hesarkhani; Farnoush Fotovat; Fatemeh Saneian; Hosein Akbari; Hanif Allahbakhshi
Journal:  Front Dent       Date:  2021-10-17