Literature DB >> 19488467

Comparison of the time required for removal of intraradicular cast posts using two Brazilian ultrasound devices.

Manoel Brito1, Janir Alves Soares, Suelleng Maria Cunha Santos, Carla Cristina Camilo, Gil Moreira.   

Abstract

The aim of this in vitro study was to compare the time required for removal of intraradicular cast posts cemented with zinc phosphate (ZF) or glass ionomer cement (GIC), using two Brazilian ultrasound devices (BUD). Seventy two human inferior premolars with single root canals were sectioned transversally at the cementoenamel junction. In each specimen, the root canal was endodontically treated, the post space was prepared to a depth of 9 mm and the canal was molded to obtain a post impression. After the casting procedures, the posts were randomly distributed into 2 groups (n = 36) according to the luting material used: G1 - ZF and G2 - GIC. The tooth and luted post set was then embedded in an acrylic resin block. The groups were then divided into 3 subgroups (n = 12) according to the ultrasound device used: A - Enac (Osada Electric, Japan), used as a control group; B - Profi II Ceramic (Dabi Atlante, Brazil) and C - Jet Sonic Satelec (Gnatus, Brazil). The posts were submitted to the vibration process with maximum power set on all surrounding surfaces. Time of application was recorded with a chronometer until complete post dislodgment, and the data were analyzed by the ANOVA test (p < 0.05). The averages required for post removal in G1 and G2 were respectively 41.42 and 92.03 seconds, with significant statistical difference (p = 0.001). No statistical difference was observed among the three ultrasound devices (p = 0.088), and the BUD presented a performance similar to that of the international gold standard device (Enac). Moreover, the type of luting agent had a greater influence on the time required for post removal than the origin of the ultrasonic unit.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19488467     DOI: 10.1590/s1806-83242009000100004

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  3 in total

1.  Influence of ultrasound, with and without water spray cooling, on removal of posts cemented with resin or glass ionomer cements: An in-vitro study.

Authors:  M S Adarsha; D A Lata
Journal:  J Conserv Dent       Date:  2010-07

2.  The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements.

Authors:  Atiyeh Feiz; Behnaz Barekatain; Roohollah Naseri; Hossein Zarezadeh; Navid Askari; Saman Nasiri
Journal:  Dent Res J (Isfahan)       Date:  2013-11

3.  Effect of ultrasonic tip designs on intraradicular post removal.

Authors:  Anny Carine Barros Aguiar; Daniely Amorim de Meireles; André Augusto Franco Marques; Emílio Carlos Sponchiado Júnior; Angela Delfina Bitencourt Garrido; Lucas da Fonseca Roberti Garcia
Journal:  Restor Dent Endod       Date:  2014-07-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.