Comparison of two ultrasonic instruments for post removal.

Eric B Dixon1, Peter J Kaczkowski, Jack I Nicholls, Gerald W Harrington.   

Abstract

The relative performance of two different ultrasonic units commonly used clinically for post removal was evaluated using tips designed specifically for post vibration. Twenty-four extracted maxillary and mandibular cuspids with crowns removed at the labial cementoenamel junction were treated endodontically. Post spaces were made 10 mm into the roots before cementing a 16 mm #5 (0.050-inch) Para-Post with zinc phosphate cement. The teeth were divided into three similar groups of eight. Post retention was assessed in group 1. Ultrasonic vibration was applied to groups 2 and 3 until post removal. The average force required to dislodge the posts from the teeth in group 1 (control group, no ultrasound) was 40.5 kg (SD = 12.3 kg). The average time for post removal in group 2 (Spartan) was 4:52 min (SD = 2:26). The average time for post removal in group 3 (Enac) was 1:31 min (SD = 0:34). The difference between groups 2 and 3 was statistically significant (p < 0.005). Use of ultrasonic tips designed for post vibration and maximization of audible sound level during ultrasonic treatment of posts seem to play an important role in the effectiveness and efficiency of post removal. The results obtained indicate that both the Enac ultrasonic unit with the ST-09 vibration tip and the Spartan ultrasonic unit with the Analytic VT-S tip were effective. Nevertheless, the Enac ultrasonic unit with the ST-09 vibration tip was clearly more efficient under these study conditions, resulting in typical post removal times of <2 min.

Entities:  

Mesh:

Year:  2002        PMID: 11833682     DOI: 10.1097/00004770-200202000-00016

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Influence of ultrasound, with and without water spray cooling, on removal of posts cemented with resin or glass ionomer cements: An in-vitro study.

Authors:  M S Adarsha; D A Lata
Journal:  J Conserv Dent       Date:  2010-07

2.  Influence of luting agents on time required for cast post removal by ultrasound: an in vitro study.

Authors:  Janir Alves Soares; Manoel Brito-Júnior; Dimitri Ribas Fonseca; Anielo Faleiro Melo; Suelleng Maria Cunha Santos; Nadia Del Carmen Soto Sotomayor; Neilor Mateus Antunes Braga; André Luis Faria e Silva
Journal:  J Appl Oral Sci       Date:  2009 May-Jun       Impact factor: 2.698

3.  The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements.

Authors:  Atiyeh Feiz; Behnaz Barekatain; Roohollah Naseri; Hossein Zarezadeh; Navid Askari; Saman Nasiri
Journal:  Dent Res J (Isfahan)       Date:  2013-11

4.  Effect of the simulated periodontal ligament on cast post-and-core removal using an ultrasonic device.

Authors:  Manoel Brito-Junior; Neilor Mateus Antunes Braga; Danilo Costa Rodrigues; Carla Cristina Camilo; André Luis Faria-e-Silva
Journal:  J Appl Oral Sci       Date:  2010 Sep-Oct       Impact factor: 2.698

5.  Effect of ultrasonic tip designs on intraradicular post removal.

Authors:  Anny Carine Barros Aguiar; Daniely Amorim de Meireles; André Augusto Franco Marques; Emílio Carlos Sponchiado Júnior; Angela Delfina Bitencourt Garrido; Lucas da Fonseca Roberti Garcia
Journal:  Restor Dent Endod       Date:  2014-07-17

6.  Retention of Cast Posts Cemented with Two Commonly Used Conventional and Two Resin Cements and the Mode of Root Fracture Following Their Removal.

Authors:  Azadeh Hesarkhani; Farnoush Fotovat; Fatemeh Saneian; Hosein Akbari; Hanif Allahbakhshi
Journal:  Front Dent       Date:  2021-10-17