Abstract

AIM: To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction.
BACKGROUND: Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution.
MATERIALS AND METHODS: Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed.
RESULTS: In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively.
CONCLUSION: Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

Entities:  

Keywords:  Cone-beam computed tomography; Dose reconstruction; Dose-volume histogram; Image-guided radiotherapy; Prostate

Year:  2012        PMID: 24377014      PMCID: PMC3863175          DOI: 10.1016/j.rpor.2012.03.003

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  17 in total

1.  Daily prostate volume and position monitoring using implanted gold markers and on-board imaging during radiotherapy.

Authors:  Linda Kasaová; Igor Sirák; Jan Jansa; Petr Paluska; Jirí Petera
Journal:  Acta Medica (Hradec Kralove)       Date:  2011

2.  Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging.

Authors:  John M Schallenkamp; Michael G Herman; Jon J Kruse; Thomas M Pisansky
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-11-01       Impact factor: 7.038

3.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation.

Authors:  Yong Yang; Eduard Schreibmann; Tianfang Li; Chuang Wang; Lei Xing
Journal:  Phys Med Biol       Date:  2007-01-12       Impact factor: 3.609

Review 4.  Image-guided radiotherapy for localized prostate cancer: treating a moving target.

Authors:  Patrick A Kupelian; Katja M Langen; Twyla R Willoughby; Omar A Zeidan; Sanford L Meeks
Journal:  Semin Radiat Oncol       Date:  2008-01       Impact factor: 5.934

5.  Rectal motion can reduce CTV coverage and increase rectal dose during prostate radiotherapy: A daily cone-beam CT study.

Authors:  Raj Sripadam; Julie Stratford; Ann M Henry; Andrew Jackson; Chris J Moore; Pat Price
Journal:  Radiother Oncol       Date:  2008-09-08       Impact factor: 6.280

6.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI).

Authors:  Michel J Ghilezan; David A Jaffray; Jeffrey H Siewerdsen; Marcel Van Herk; Anil Shetty; Michael B Sharpe; Syed Zafar Jafri; Frank A Vicini; Richard C Matter; Donald S Brabbins; Alvaro A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-06-01       Impact factor: 7.038

7.  Measurement of prostate movement over the course of routine radiotherapy using implanted markers.

Authors:  J M Balter; H M Sandler; K Lam; R L Bree; A S Lichter; R K ten Haken
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-01-01       Impact factor: 7.038

8.  Quantitative evaluation of cone-beam computed tomography in target volume definition for offline image-guided radiation therapy of prostate cancer.

Authors:  Weihu Wang; Qiuwen Wu; Di Yan
Journal:  Radiother Oncol       Date:  2009-11-10       Impact factor: 6.280

Review 9.  Different styles of image-guided radiotherapy.

Authors:  Marcel van Herk
Journal:  Semin Radiat Oncol       Date:  2007-10       Impact factor: 5.934

Review 10.  Cyberknife: A double edged sword?

Authors:  Bindhu Joseph; Sanjay S Supe; Aruna Ramachandra
Journal:  Rep Pract Oncol Radiother       Date:  2010-07-06
View more
  12 in total

1.  Assessment and evaluation of MV image guidance system performance in radiotherapy.

Authors:  Nithya Kanakavelu; E James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-07

2.  Evaluation of cone-beam computed tomography image quality assurance for Vero4DRT system.

Authors:  Hideharu Miura; Shuichi Ozawa; Masahiro Hayata; Shintarou Tsuda; Tsubasa Enosaki; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

3.  Empirical estimation of beam-on time for prostate cancer patients treated on Tomotherapy.

Authors:  Małgorzata Skórska; Tomasz Piotrowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-02-04

4.  Comparing morbidity and cancer control after 3D-conformal (70/74 Gy) and intensity modulated radiotherapy (78/82 Gy) for prostate cancer.

Authors:  Martin Dolezel; Karel Odrazka; Milan Zouhar; Miloslava Vaculikova; Jana Sefrova; Jan Jansa; Petr Paluska; Tereza Kohlova; Jaroslav Vanasek; Josef Kovarik
Journal:  Strahlenther Onkol       Date:  2015-01-15       Impact factor: 3.621

5.  On voxel-by-voxel accumulated dose for prostate radiation therapy using deformable image registration.

Authors:  Jialu Yu; Nicholas Hardcastle; Kyoungkeun Jeong; Edward T Bender; Mark A Ritter; Wolfgang A Tomé
Journal:  Technol Cancer Res Treat       Date:  2014-11-11

6.  Displacements of fiducial markers in patients with prostate cancer treated with image guided radiotherapy: A single-institution descriptive study.

Authors:  Ricardo Cendales; Felipe Torres; Juan Arbelaez; Armando Gaitan; Jaider Vasquez; Ivan Bobadilla
Journal:  Rep Pract Oncol Radiother       Date:  2014-09-01

7.  Comparative analysis of image guidance in two institutions for prostate cancer patients.

Authors:  Tomasz Piotrowski; Slav Yartsev; George Rodrigues; Tomasz Bajon
Journal:  Rep Pract Oncol Radiother       Date:  2014-01-02

Review 8.  Target margins in radiotherapy of prostate cancer.

Authors:  Slav Yartsev; Glenn Bauman
Journal:  Br J Radiol       Date:  2016-07-20       Impact factor: 3.039

9.  Evaluation of image-guidance strategies for prostate cancer.

Authors:  T Piotrowski; K Kaczmarek; T Bajon; A Ryczkowski; A Jodda; J Kaźmierska
Journal:  Technol Cancer Res Treat       Date:  2013-08-31

10.  Impact of the Intra- and Inter-observer Variability in the Delineation of Parotid Glands on the Dose Calculation During Head and Neck Helical Tomotherapy.

Authors:  T Piotrowski; K Gintowt; A Jodda; A Ryczkowski; W Bandyk; B Ba K; M Adamczyk; M Skorska; J Kazmierska; J Malicki
Journal:  Technol Cancer Res Treat       Date:  2015-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.