Literature DB >> 22283108

Daily prostate volume and position monitoring using implanted gold markers and on-board imaging during radiotherapy.

Linda Kasaová1, Igor Sirák, Jan Jansa, Petr Paluska, Jirí Petera.   

Abstract

PURPOSE: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy.
METHODS: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery.
RESULTS: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate's initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 +/- 1 mm on average. The extension of intrafraction movements was 7.6 +/- 0.2 mm on average.
CONCLUSIONS: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22283108     DOI: 10.14712/18059694.2016.39

Source DB:  PubMed          Journal:  Acta Medica (Hradec Kralove)        ISSN: 1211-4286


  2 in total

1.  Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

Authors:  Petr Paluska; Josef Hanus; Jana Sefrova; Lucie Rouskova; Jakub Grepl; Jan Jansa; Linda Kasaova; Miroslav Hodek; Milan Zouhar; Milan Vosmik; Jiri Petera
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-05

2.  Utilization of cone beam CT for reconstruction of dose distribution delivered in image-guided radiotherapy of prostate carcinoma - bony landmark setup compared to fiducial markers setup.

Authors:  Petr Paluska; Josef Hanus; Jana Sefrova; Lucie Rouskova; Jakub Grepl; Jan Jansa; Linda Kasaova; Miroslav Hodek; Milan Zouhar; Milan Vosmik; Jiri Petera
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102