Literature DB >> 24372319

Effect of osmotherapy on optic nerve sheath diameter in patients with increased intracranial pressure.

Yoann Launey1, Nicolas Nesseler, Pascale Le Maguet, Yannick Mallédant, Philippe Seguin.   

Abstract

The measurement of ocular nerve sheath diameter (ONSD) via ocular ultrasound scanning is a recent non-invasive method for intracranial pressure (ICP) assessment. Few clinical studies have assessed ONSD variations during osmotherapy for the treatment of sustained increased ICP episodes. The aim of our study was to determine the rate of ONSD variation after mannitol administration for increased ICP episodes. We consecutively included in a prospective, observational study, the patients who had severe acute brain injury and monitored with an invasive ICP monitor. For each episode of sustained elevated ICP, the ONSD was measured in the right and left eye with a 7.5-MHz echography probe, and the mean value was reported. Simultaneously, ICP and cerebral perfusion pressure (CPP) were recorded. All measurements were performed just before and 20 minutes following a 20% mannitol infusion. Data were expressed as medians and interquartile ranges. Thirteen patients were included and analysed (traumatic brain injury, n=10; subarachnoid haemorrhage, n=3). The median value of the mannitol dose infused was 0.54 g/kg (0.49-0.80 g/kg). In all cases, the ONSD was greater than 5.8 mm before osmotherapy. The ONSD significantly decreased after mannitol infusion from 6.3 (6.1-6.7) to 5. mm (5.5-6.3) (p=0.0007). Concomitantly, the intracranial pressure decreased from 35 (32-41) to 25 (22-29) mmHg (p=0.001) and the CPP increased from 47 (50-60) to 66 (59-69) mmHg (p=0.003). The variations of ONSD appear to be an interesting parameter to evaluate the efficacy of osmotherapy for elevated ICP episodes in patients with acute brain injury.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24372319     DOI: 10.1089/neu.2012.2829

Source DB:  PubMed          Journal:  J Neurotrauma        ISSN: 0897-7151            Impact factor:   5.269


  21 in total

Review 1.  Fluid therapy in neurointensive care patients: ESICM consensus and clinical practice recommendations.

Authors:  Mauro Oddo; Daniele Poole; Raimund Helbok; Geert Meyfroidt; Nino Stocchetti; Pierre Bouzat; Maurizio Cecconi; Thomas Geeraerts; Ignacio Martin-Loeches; Hervé Quintard; Fabio Silvio Taccone; Romergryko G Geocadin; Claude Hemphill; Carole Ichai; David Menon; Jean-François Payen; Anders Perner; Martin Smith; José Suarez; Walter Videtta; Elisa R Zanier; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2018-03-02       Impact factor: 17.440

2.  Ultrasonographic optic nerve sheath diameter monitoring of elevated intracranial pressure: two case reports.

Authors:  Li-Juan Wang; Hong-Xiu Chen; Lan Tong; Li-Min Chen; Ya-Nan Dong; Ying-Qi Xing
Journal:  Ann Transl Med       Date:  2020-01

Review 3.  Ultrasound Detection of Intracranial Hypertension in Brain Injuries.

Authors:  Livio Vitiello; Giulio Salerno; Maddalena De Bernardo; Olga D'Aniello; Luigi Capasso; Giuseppe Marotta; Nicola Rosa
Journal:  Front Med (Lausanne)       Date:  2022-06-30

4.  Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.

Authors:  Li-Juan Wang; Li-Min Chen; Ying Chen; Li-Yang Bao; Nan-Nan Zheng; Yu-Zhi Wang; Ying-Qi Xing
Journal:  JAMA Ophthalmol       Date:  2018-03-01       Impact factor: 7.389

5.  Association between optic nerve sheath diameter and mortality in patients with severe traumatic brain injury.

Authors:  Mypinder S Sekhon; Paul McBeth; Jie Zou; Lu Qiao; Leif Kolmodin; William R Henderson; Steve Reynolds; Donald E G Griesdale
Journal:  Neurocrit Care       Date:  2014-10       Impact factor: 3.210

Review 6.  Intraoperative non invasive intracranial pressure monitoring during pneumoperitoneum: a case report and a review of the published cases and case report series.

Authors:  C Robba; S Bacigaluppi; D Cardim; J Donnelly; M S Sekhon; M J Aries; G Mancardi; A Booth; N L Bragazzi; M Czosnyka; B Matta
Journal:  J Clin Monit Comput       Date:  2015-09-05       Impact factor: 2.502

7.  Correlating optic nerve sheath diameter with opening intracranial pressure in pediatric traumatic brain injury.

Authors:  Adam M H Young; Mathew R Guilfoyle; Joseph Donnelly; Daniel Scoffings; Helen Fernandes; Mathew Garnett; Shruti Agrawal; Peter J Hutchinson
Journal:  Pediatr Res       Date:  2016-08-11       Impact factor: 3.756

8.  Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury.

Authors:  Mypinder S Sekhon; Donald E Griesdale; Chiara Robba; Nick McGlashan; Edward Needham; Katherine Walland; Alyssa C Shook; Peter Smielewski; Marek Czosnyka; Arun K Gupta; David K Menon
Journal:  Intensive Care Med       Date:  2014-07-18       Impact factor: 17.440

9.  Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Li-Juan Wang; Yan Yao; Liang-Shu Feng; Yu-Zhi Wang; Nan-Nan Zheng; Jia-Chun Feng; Ying-Qi Xing
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

10.  The assessment of the effect of different intraabdominal pressures used for laparoscopic cholecystectomy surgery on optic nerve sheath diameter: a prospective observational cohort study

Authors:  Tuna Ertürk; Bülent Barış Güven; Yadigar Yılmaz; Fulya Yurtsever; Ayşın Ersoy
Journal:  Turk J Med Sci       Date:  2021-06-28       Impact factor: 0.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.