Literature DB >> 24368093

Evaluation of hemodynamically severe coronary stenosis as determined by fractional flow reserve with frequency domain optical coherence tomography measured anatomical parameters.

Haroon Zafar1, Ihsan Ullah2, Kate Dinneen2, Sajjad Matiullah2, Alan Hanley2, Martin J Leahy3, Faisal Sharif4.   

Abstract

OBJECTIVES: The main objective of this study is to determine the correlation between fractional flow reserve (FFR)- and frequency domain optical coherence tomography (FD-OCT)-measured lumen parameters, and to determine the diagnostic competence of FD-OCT concerning the identification of severe coronary stenosis.
METHODS: A total of 41 coronary stenoses in 30 patients were assessed consecutively by quantitative coronary angiography (QCA), FFR, and FD-OCT. Stenoses were labeled severe if FFR ≤ 0.80. The minimal lumen area (MLA), minimal lumen diameter (MLD), and percent lumen area stenosis (%AS) were measured using FD-OCT.
RESULTS: FFR was ≤ 0.80 in 10 stenoses (24.4%). A poor but significant correlation between FFR and FD-OCT-measured MLA (r(2) = 0.4, p < 0.001), MLD (r(2) = 0.28, p < 0.001), and %AS (r(2) = 0.13, p = 0.02) was found. In the overall group, the diagnostic efficiency of MLA and MLD in identifying significant stenosis was moderate. The area under the curve (AUC) was 0.80 [95% confidence interval (CI): 0.64-0.91] for MLA and 0.76 (95% CI: 0.60-0.88) for MLD. The best cut-off values of FD-OCT-measured lumen parameters to identify stenosis with FFR ≤ 0.80 were 1.62 mm(2) [specificity 97%, sensitivity 70%, positive predictive value (PPV) 89% and negative predictive value (NPV) 91%] for MLA and 1.23 mm (specificity 87%, sensitivity 70%, PPV 64% and NPV 90%) for MLD. The diagnostic efficiency of MLA in identifying significant stenosis in vessels having reference diameter < 3 mm was high. The AUC was 0.96 (95% CI: 0.83-1.0).
CONCLUSIONS: The FFR values and FD-OCT anatomical parameters MLA, MLD were found to be significantly correlated. In the overall group, the FD-OCT-measured MLA and MLD have shown moderate diagnostic efficiency in the functional evaluation of significant stenosis. FD-OCT-measured MLA has high diagnostic efficiency in identifying severe coronary stenosis in vessels having reference diameter < 3 mm.
Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Coronary stenosis; Fractional flow reserve; Frequency domain optical coherence tomography; Minimal lumen area; Minimal lumen diameter

Mesh:

Year:  2013        PMID: 24368093     DOI: 10.1016/j.jjcc.2013.11.009

Source DB:  PubMed          Journal:  J Cardiol        ISSN: 0914-5087            Impact factor:   3.159


  11 in total

Review 1.  A systematic review of imaging anatomy in predicting functional significance of coronary stenoses determined by fractional flow reserve.

Authors:  Miao Chu; Neng Dai; Junqing Yang; Jelmer Westra; Shengxian Tu
Journal:  Int J Cardiovasc Imaging       Date:  2017-03-06       Impact factor: 2.357

2.  Correlation between optical coherence tomography-derived intraluminal parameters and fractional flow reserve measurements in intermediate grade coronary lesions: a comparison between diabetic and non-diabetic patients.

Authors:  Sebastian Reith; Simone Battermann; Martin Hellmich; Nikolaus Marx; Mathias Burgmaier
Journal:  Clin Res Cardiol       Date:  2014-08-15       Impact factor: 5.460

Review 3.  A Practical Approach to Assessing Stent Results with IVUS or OCT.

Authors:  Daisuke Hachinohe; Satoru Mitomo; Luciano Candilio; Azeem Latib
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Jan-Mar

4.  Performing and Interpreting Fractional Flow Reserve Measurements in Clinical Practice: An Expert Consensus Document.

Authors:  Stephan Achenbach; Tanja Rudolph; Johannes Rieber; Holger Eggebrecht; Gert Richardt; Thomas Schmitz; Nikos Werner; Florian Boenner; Helge Möllmann
Journal:  Interv Cardiol       Date:  2017-09

Review 5.  The Continuum of Invasive Techniques for the Assessment of Intermediate Coronary Lesions.

Authors:  Nicoleta-Monica Popa-Fotea; Alexandru Scafa-Udriste; Maria Dorobantu
Journal:  Diagnostics (Basel)       Date:  2022-06-18

Review 6.  Critical analysis of the correlation between optical coherence tomography versus intravascular ultrasound and fractional flow reserve in the management of intermediate coronary artery lesion.

Authors:  Yan-Feng Ma; Jiang-Ming Fam; Bu-Chun Zhang
Journal:  Int J Clin Exp Med       Date:  2015-05-15

Review 7.  Optical Coherence Tomography of the Coronary Arteries.

Authors:  Robert Roland; Josef Veselka
Journal:  Int J Angiol       Date:  2021-02-12

8.  Measurement of the blood flow rate and velocity in coronary artery stenosis using intracoronary frequency domain optical coherence tomography: Validation against fractional flow reserve.

Authors:  Haroon Zafar; Faisal Sharif; Martin J Leahy
Journal:  Int J Cardiol Heart Vasc       Date:  2014-10-16

9.  Characterization of various acrylate based artificial teeth for denture fabrication.

Authors:  Nawshad Muhammad; Zenab Sarfraz; Muhammad Sohail Zafar; Saad Liaqat; Abdur Rahim; Pervaiz Ahmad; Abdullah Alsubaie; Abdulraheem S A Almalki; Mayeen Uddin Khandaker
Journal:  J Mater Sci Mater Med       Date:  2022-01-24       Impact factor: 3.896

10.  OCT-Derived Plaque Morphology and FFR-Determined Hemodynamic Relevance in Intermediate Coronary Stenoses.

Authors:  Mariusz Tomaniak; Dorota Ochijewicz; Łukasz Kołtowski; Adam Rdzanek; Arkadiusz Pietrasik; Jacek Jąkała; Magdalena Slezak; Krzysztof P Malinowski; Martyna Zaleska; Jakub Maksym; Piotr Barus; Tomasz Roleder; Krzysztof J Filipiak; Grzegorz Opolski; Janusz Kochman
Journal:  J Clin Med       Date:  2021-05-28       Impact factor: 4.241

View more