Magnitude of loads influences the site of failure of highly curved bones.

James Macione1, Robert Sterling Nesbitt1, Shiva Kotha2.   

Abstract

The structure and material properties of bones along with applied boundary conditions determine the region of peak stresses, where fracture is expected to occur. As the site of peak stresses is not influenced by the magnitude of applied load, the fracture site is not expected to change during fatigue loading of whole bone at different loads. However, in a highly curved bone such as the rat ulna, the magnitude of applied loads was found to influence the fracture site. Fatigue loading was conducted under load control on intact rat forearms and on excised ulnae. The distance to the site of failure from the proximal olecranon process of ulnae was determined. In intact forearms, the site of failure demonstrated a linear progression distally, towards sites with lower moment of inertia (or sites exhibiting lower section modulus). Intact rat forearms and excised ulnae loaded to failure at low loads fractured 2-3mm distal to where they failed when applying high loads. This indicates a shift in the site of failure by approximately 10% of whole bone length just by varying the applied load magnitude. The site of failure in excised ulnae was similar when loading at 2Hz or at 4Hz, suggesting that this was frequency independent in this range and indicating that strain rate was not an important contributing factor. Creep loading of excised ulnae also demonstrated similar changes in the site of failure, indicating that magnitude of loads, and not type of loading were important in determining the site of failure. This has important implications with regards to the volume of bone that undergoes damage under physiological loading, before it fails.
© 2013 Published by Elsevier Ltd.

Entities:  

Keywords:  Fatigue; Moment of inertia; Rat forearm compression loading; Shift in fracture site; Ulnar failure

Mesh:

Year:  2013        PMID: 24361931      PMCID: PMC3928149          DOI: 10.1016/j.jmbbm.2013.11.018

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  14 in total

Review 1.  How well are bones designed to resist fracture?

Authors:  John D Currey
Journal:  J Bone Miner Res       Date:  2003-04       Impact factor: 6.741

2.  A combined finite element method and continuum damage mechanics approach to simulate the in vitro fatigue behavior of human cortical bone.

Authors:  M Taylor; N Verdonschot; R Huiskes; P Zioupos
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

3.  Design and analysis of a novel mechanical loading machine for dynamic in vivo axial loading.

Authors:  James Macione; Sterling Nesbitt; Vaibhav Pandit; Shiva Kotha
Journal:  Rev Sci Instrum       Date:  2012-02       Impact factor: 1.523

4.  The importance of the elastic and plastic components of strain in tensile and compressive fatigue of human cortical bone in relation to orthopaedic biomechanics.

Authors:  K Winwood; P Zioupos; J D Currey; J R Cotton; M Taylor
Journal:  J Musculoskelet Neuronal Interact       Date:  2006 Apr-Jun       Impact factor: 2.041

5.  Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.

Authors:  Peter Zioupos; Ulrich Hansen; John D Currey
Journal:  J Biomech       Date:  2008-09-10       Impact factor: 2.712

6.  Load/strain distribution between ulna and radius in the mouse forearm compression loading model.

Authors:  Yunkai Lu; Ganesh Thiagarajan; Daniel P Nicolella; Mark L Johnson
Journal:  Med Eng Phys       Date:  2011-09-07       Impact factor: 2.242

7.  Bone creep-fatigue damage accumulation.

Authors:  W E Caler; D R Carter
Journal:  J Biomech       Date:  1989       Impact factor: 2.712

8.  Cyclic mechanical property degradation during fatigue loading of cortical bone.

Authors:  C A Pattin; W E Caler; D R Carter
Journal:  J Biomech       Date:  1996-01       Impact factor: 2.712

9.  Experimental and finite element analysis of the rat ulnar loading model-correlations between strain and bone formation following fatigue loading.

Authors:  S P Kotha; Y-F Hsieh; R M Strigel; R Müller; M J Silva
Journal:  J Biomech       Date:  2004-04       Impact factor: 2.712

10.  A cumulative damage model for bone fracture.

Authors:  D R Carter; W E Caler
Journal:  J Orthop Res       Date:  1985       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.