| Literature DB >> 24353887 |
Min-Jeong Kim1, Kyo-Han Kim2, Young-Kyung Kim3, Tae-Yub Kwon2.
Abstract
PURPOSE: The aim of this Fourier transform infrared (FTIR) spectroscopic study was to measure the degree of conversion (DC) of dual-cured resin cements light-irradiated through zirconia ceramic disks with different thicknesses using various light-curing methods.Entities:
Keywords: Degree of conversion; Resin cement; Zirconia ceramic
Year: 2013 PMID: 24353887 PMCID: PMC3865204 DOI: 10.4047/jap.2013.5.4.464
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Two dual-cured resin cements tested
Monomer abbreviations: Bis-GMA, bisphenol A diglycidyl methacrylate; TEGDMA, triethylene glycol dimethacrylate; UDMA, urethane dimethacrylate; 10-MDP, 10-methacryloyloxydecyl dihydrogenphosphate.
Fig. 1Schematic diagrams showing the measurements of the light transmittance of zirconia disk (A) and the degree of conversion for the resin cements light-irradiated through zirconia disk.
Fig. 2Light transmittance of the KT12 zirconia disks with different thicknesses.
Degree of conversion (%) of Duo-Link light-irradiated through KT12 zirconia disks (mean ± SD, n=5)
*TS: Elipar TriLight, standard mode; BH: bluephase G2,highpower mode; 40 or 120: light-exposure time (seconds).
†Within the same curing mode and the same thickness, each superscripted value is significantly different from the value at 10 minutes (repeated measures ANOVA, P<.05).
Degree of conversion (%) of Panavia F2.0 light-irradiated through KT12 zirconia disks (mean ± SD, n=5)
*TS: Elipar TriLight, standard mode; BH: bluephase G2,highpower mode; 40 or 120: light-exposure time (seconds).
†Within the same curing mode and the same thickness, each superscripted value is significantly different from the value at 10 minutes (repeated measures ANOVA, P<.05).
Fig. 3Ten minute degree of conversion of the two resin cements. The vertical bar indicates the standard deviation. Within a material, the same lower case letters indicate statistically similar values within each thickness; the horizontal lines above the adjacent bars indicate statistically similar values within each curing mode (ANOVA and Tukey' test, P>.05). TS: Elipar TriLight, standard mode; BH: bluephase G2,high power mode; 40 or 120: light-exposure time (seconds).