Effect of different power settings of Er,Cr:YSGG laser before or after tribosilicatization on the microshear bond strength between zirconia and two types of cements.

Leonardo C Zeidan1, Camila M Esteves1, Juliana A Oliveira1, Aldo Brugnera2, Alessandra Cassoni1, José Augusto Rodrigues3.   

Abstract

The aim of this study was to evaluate the effect of different output powers of Er,Cr:YSGG laser and the association with tribochemical silica coating on the bond strength between zirconia ceramic and two resin cements. One hundred ninety-two zirconia ceramic bars (IPS e-max ZirCAD Ivoclar Vivadent-) were sectioned (6 × 6 × 4 mm), sintered, and randomly divided into 12 groups for each cement system according to the surface treatment (n = 8): C-without treatment (control); R-tribochemical coating + resin cement (control); 2L-laser (2.0 W) + resin cement; 2LR-laser (2.0 W) + tribochemical coating + resin cement; R2L-tribochemical coating + laser (2.0 W) + resin cement; 2.5L-laser (2.5 W) + resin cement; 2.5LR-laser (2.5 W) + tribochemical coating + resin cement; R2.5L-tribochemical coating + laser (2.5 W) + resin cement; 3L-laser (3.0 W) + resin cement; 3LR-laser (3.0 W) + tribochemical coating + resin cement, R3L-tribochemical coating + laser (3.0 W) + resin cement; and RPHO-tribochemical + resin cement + photoactivation (control). After the surface treatment, the respective primers were applied, and resin cements, Multilink N, Ivoclar Vivadent (M), and Panavia F 2.0, Kuraray Medical Inc. (P), were inserted into Tygon molds which were bonded to the zirconia bars. Each specimen received two cements bars. After 24 h of storage in a relative humidity (100%) at 37 °C, they were evaluated by the microshear test speed of 1 mm/min. The microshear values were analyzed by one-way ANOVA and Tukey's test (α = 0.05). ANOVA showed statistically significant differences among the evaluated groups. The highest bond strength was observed in RPHO, which statistically differed from all groups. The lowest bond strength was observed in M2.5L (Multilink N) and in P3LR (Panavia F 2.0). It can be concluded that the lowest power output tested was suitable and showed bond strength values similar to tribochemical silica deposition. The light curing is important to adhesion and the tribosilicatizated surface achieves similar microshear values to untreated surface in absence of light.

Entities:  

Keywords:  Bond strength; Laser; Microshear; Zirconia

Mesh:

Substances:

Year:  2017        PMID: 29075997     DOI: 10.1007/s10103-017-2343-2

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  33 in total

1.  Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements.

Authors:  Simon Flury; Adrian Lussi; Reinhard Hickel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2013-02-08       Impact factor: 3.573

2.  The effect of laser treatment on bonding between zirconia ceramic surface and resin cement.

Authors:  Çağrı Ural; Tolga Külünk; Şafak Külünk; Murat Kurt
Journal:  Acta Odontol Scand       Date:  2010-11       Impact factor: 2.331

3.  Influence of Y-TZP ceramic treatment and different resin cements on bond strength to dentin.

Authors:  Humberto L de Castro; Pedro H Corazza; Tarcísio de A Paes-Júnior; Alvaro Della Bona
Journal:  Dent Mater       Date:  2012-09-20       Impact factor: 5.304

4.  Durability of the resin bond strength to zirconia ceramic after using different surface conditioning methods.

Authors:  Mona Wolfart; Frank Lehmann; Stefan Wolfart; Matthias Kern
Journal:  Dent Mater       Date:  2006-01-20       Impact factor: 5.304

5.  Bond strength of resin cement to yttrium-stabilized tetragonal zirconia ceramic treated with air abrasion, silica coating, and laser irradiation.

Authors:  Musa Samil Akyil; Ismail Hakki Uzun; Funda Bayindir
Journal:  Photomed Laser Surg       Date:  2010-10-22       Impact factor: 2.796

6.  Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics.

Authors:  J Tinschert; D Zwez; R Marx; K J Anusavice
Journal:  J Dent       Date:  2000-09       Impact factor: 4.379

7.  Surface roughness and bond strengths of glass-infiltrated alumina-ceramics prepared using various surface treatments.

Authors:  Bahadir Ersu; Bulem Yuzugullu; A Ruya Yazici; Senay Canay
Journal:  J Dent       Date:  2009-07-01       Impact factor: 4.379

8.  In vitro shear bond strength of Y-TZP ceramics to different core materials with the use of three primer/resin cement systems.

Authors:  Fahad A Al-Harbi; Neveen M Ayad; Zahid A Khan; Amr A Mahrous; Steven M Morgano
Journal:  J Prosthet Dent       Date:  2015-09-26       Impact factor: 3.426

9.  Effects of Different Surface Treatment Methods and MDP Monomer on Resin Cementation of Zirconia Ceramics an In Vitro Study.

Authors:  Merve Çakırbay Tanış; Cihan Akçaboy
Journal:  J Lasers Med Sci       Date:  2015-10-27

Review 10.  Zirconia as a ceramic biomaterial.

Authors:  C Piconi; G Maccauro
Journal:  Biomaterials       Date:  1999-01       Impact factor: 12.479

View more
  3 in total

1.  Effect of Fiber Laser Irradiation on the Shear Bond Strength between Acrylic Resin and Titanium.

Authors:  Fatih Mehmet Korkmaz; Selin Aycan
Journal:  Scanning       Date:  2019-09-03       Impact factor: 1.932

Review 2.  Effect of laser irradiation on bond strength between zirconia and resin cement or veneer ceramic: A systematic review and meta-analysis.

Authors:  Sandro Basso Bitencourt; Letícia Chaves Ferreira; Leticia Cerri Mazza; Daniela Micheline Dos Santos; Aldieris Alves Pesqueira; Leticia Helena Theodoro
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

Review 3.  What Is the Most Effective Technique for Bonding Brackets on Ceramic-A Systematic Review and Meta-Analysis.

Authors:  Inês Francisco; Raquel Travassos; Catarina Nunes; Madalena Ribeiro; Filipa Marques; Flávia Pereira; Carlos Miguel Marto; Eunice Carrilho; Bárbara Oliveiros; Anabela Baptista Paula; Francisco Vale
Journal:  Bioengineering (Basel)       Date:  2022-01-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.