Literature DB >> 24351314

Assessment of myocardial adrenergic innervation with a solid-state dedicated cardiac cadmium-zinc-telluride camera: first clinical experience.

Alessia Gimelli1, Riccardo Liga, Assuero Giorgetti, Dario Genovesi, Paolo Marzullo.   

Abstract

AIMS: To investigate the relationships between regional adrenergic innervation heterogeneity, myocardial perfusion, and contractile function obtained by means of a low-dose imaging protocol with a cadmium-zinc-telluride (CZT) dedicated camera.
METHODS: Twenty-eight patients with or without ischaemic heart disease underwent (123)I-metaiodobenzylguanidine (MIBG) planar scintigraphic and CZT early and delayed evaluations followed by (99m)Tc-tetrofosmin rest gated CZT with a single-day protocol. The heart-to-mediastinum ratio and the washout rate were computed from planar (123)I-MIBG images. The summed (123)I-MIBG defect scores (SS-MIBG) were semi-quantitatively assessed from CZT images. The summed rest score (SRS), summed motion score (SMS), and summed thickening score (STS) were quantitated from (99m)Tc-tetrofosmin images.
RESULTS: Sixteen patients showed a depressed left ventricular systolic function [ejection fraction (EF)<50%]. They presented higher SRS (P = 0.007), SMS (P < 0.001), STS (P < 0.001), and early SS-MIBG (P = 0.007) values than those with normal contractile function. Interestingly, higher early SS-MIBG values, index of regional sympathetic innervation heterogeneity, clustered with more elevated SRS (P = 0.023), and more impaired measures of regional and global left ventricle systolic function, i.e. SMS (P = 0.046), STS (P = 0.014), and EF (P = 0.027). At multivariate analysis, a higher SRS (P = 0.039) remained the only independent predictor of more elevated early SS-MIBG values. In the 20 of 28 ischaemic patients, the correlations between early SS-MIBG and SMS (P = 0.017) and also STS (P = 0.036) were further confirmed. The effective dose of the investigation was 4.2 ± 0.72 mSv.
CONCLUSIONS: An altered early SS-MIBG, assessed with a low-dose imaging protocol and a CZT cardiac camera, identifies patients with more impaired myocardial perfusion and contractile function.

Entities:  

Keywords:  123I-MIBG; CZT camera; Cardiac innervation; Heart-to-mediastinum ratio

Mesh:

Substances:

Year:  2013        PMID: 24351314     DOI: 10.1093/ehjci/jet258

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  17 in total

1.  Relationships between cardiac innervation/perfusion imbalance and ventricular arrhythmias: impact on invasive electrophysiological parameters and ablation procedures.

Authors:  Alessia Gimelli; Francesca Menichetti; Ezio Soldati; Riccardo Liga; Andrea Vannozzi; Paolo Marzullo; Maria Grazia Bongiorni
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-07-19       Impact factor: 9.236

2.  It's not all in the numbers.

Authors:  Mark I Travin
Journal:  J Nucl Cardiol       Date:  2015-03-24       Impact factor: 5.952

3.  First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study.

Authors:  Tanguy Blaire; Alban Bailliez; Fayçal Ben Bouallegue; Dimitri Bellevre; Denis Agostini; Alain Manrique
Journal:  J Nucl Cardiol       Date:  2017-03-08       Impact factor: 5.952

4.  Interactions between myocardial sympathetic denervation and left ventricular mechanical dyssynchrony: A CZT analysis.

Authors:  Alessia Gimelli; Riccardo Liga; Francesca Menichetti; Ezio Soldati; Maria Grazia Bongiorni; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2017-08-14       Impact factor: 5.952

5.  Evaluation of myocardial sympathetic innervation in the 21st century: Is there a role for planar 123I-MIBG imaging?

Authors:  Riccardo Liga; Veronica Della Tommasina
Journal:  J Nucl Cardiol       Date:  2016-06-01       Impact factor: 5.952

6.  Imaging the heart's brain: Simultaneous innervation/perfusion analysis in the era of new CZT cameras.

Authors:  Riccardo Liga; Alessia Gimelli
Journal:  J Nucl Cardiol       Date:  2016-05-18       Impact factor: 5.952

7.  Dual isotope and multidetector camera: The best choices for a specific end-point.

Authors:  Roberta Assante; Wanda Acampa
Journal:  J Nucl Cardiol       Date:  2016-05-19       Impact factor: 5.952

8.  Optimization of a simultaneous dual-isotope 201Tl/123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Authors:  Emmanuel D'estanque; Christophe Hedon; Benoît Lattuca; Aurélie Bourdon; Meriem Benkiran; Aurélie Verd; François Roubille; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2016-05-25       Impact factor: 5.952

9.  ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers.

Authors:  Milena J Henzlova; W Lane Duvall; Andrew J Einstein; Mark I Travin; Hein J Verberne
Journal:  J Nucl Cardiol       Date:  2016-06       Impact factor: 5.952

10.  Regional heterogeneity in cardiac sympathetic innervation in acute myocardial infarction: relationship with myocardial oedema on magnetic resonance.

Authors:  Alessia Gimelli; Pier Giorgio Masci; Riccardo Liga; Chrysanthos Grigoratos; Emilio Maria Pasanisi; Massimo Lombardi; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05-13       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.