Accuracy of pulse oximeters in estimating heart rate at rest and during exercise.

Y Iyriboz1, S Powers, J Morrow, D Ayers, G Landry.   

Abstract

Pulse oximeters are being widely used for non-invasive, simultaneous assessment of haemoglobin oxygen saturation. They are reliable, accurate, relatively inexpensive and portable. Pulse oximeters are often used for estimating heart rate at rest and during exercise. However, at present the data available to validate their use as heart rate monitors are not sufficient. We evaluated the accuracy of two oximeters (Radiometer, ear and finger probe; Ohmeda 3700, ear probe) in monitoring heart rate during incremental exercise by comparing the pulse oximeters with simultaneous ECG readings. Data were collected on eight men (713 heart rate readings) during graded cycle ergometer and treadmill exercise to volitional fatigue. Analysis by linear regression revealed that general oximeter readings significantly correlated with those of ECG (r = 0.91, P less than 0.0001). However, comparison of heart rate at each level of work showed that oximeter readings significantly (P less than 0.05) under-estimated rates above 155 beats/min. These results indicate that the use of pulse oximeters as heart rate monitors during strenuous exercise is questionable. This inaccuracy may well originate from the instability of the probes, sweating, other artefacts during exercise, and measurement of different components in the cardiovascular cycle.

Entities:  

Mesh:

Year:  1991        PMID: 1777787      PMCID: PMC1478836          DOI: 10.1136/bjsm.25.3.162

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  6 in total

1.  Exercise testing for evaluation of ventricular function.

Authors:  R A Bruce
Journal:  N Engl J Med       Date:  1977-03-24       Impact factor: 91.245

2.  Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.

Authors:  M S Jennis; J L Peabody
Journal:  Pediatrics       Date:  1987-04       Impact factor: 7.124

3.  Heart- or respiration-rate calculator.

Authors:  H Ludwig
Journal:  Med Biol Eng Comput       Date:  1977-11       Impact factor: 2.602

4.  Pulse oximetry advantages in infants with bronchopulmonary dysplasia.

Authors:  A J Solimano; J A Smyth; T K Mann; S G Albersheim; G Lockitch
Journal:  Pediatrics       Date:  1986-11       Impact factor: 7.124

5.  Monitoring the resuscitation of preterm infants in the delivery room using pulse oximetry.

Authors:  L G Maxwell; A P Harris; M J Sendak; R T Donham
Journal:  Clin Pediatr (Phila)       Date:  1987-01       Impact factor: 1.168

6.  Pulse oximetry in very low birth weight infants with acute and chronic lung disease.

Authors:  R Ramanathan; M Durand; C Larrazabal
Journal:  Pediatrics       Date:  1987-04       Impact factor: 7.124

  6 in total
  13 in total

1.  Validation of a Self-Monitoring Tool for Use in Exercise Therapy.

Authors:  Camilla S Powierza; Michael D Clark; Jaime M Hughes; Kevin A Carneiro; Jason P Mihalik
Journal:  PM R       Date:  2017-04-09       Impact factor: 2.298

2.  Physiological Arousal and Juvenile Psychopathy: Is Low Resting Heart Rate Associated with Affective Dimensions?

Authors:  Nicholas Kavish; Michael G Vaughn; Eunsoo Cho; Amy Barth; Brian Boutwell; Sharon Vaughn; Philip Capin; Stephanie Stillman; Leticia Martinez
Journal:  Psychiatr Q       Date:  2017-03

3.  Heart Rate and Electrocardiography Monitoring in Mice.

Authors:  David Ho; Xin Zhao; Shumin Gao; Chull Hong; Dorothy E Vatner; Stephen F Vatner
Journal:  Curr Protoc Mouse Biol       Date:  2011-03-01

4.  Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

Authors:  Jiahui Wang; Junwei Han; Vinh T Nguyen; Lei Guo; Christine C Guo
Journal:  Front Neurosci       Date:  2017-05-08       Impact factor: 4.677

5.  Possible Link Between Stress-related Factors and Altered Body Composition in Women with Polycystic Ovarian Syndrome.

Authors:  Barnali Ray Basu; Olivia Chowdhury; Sudip Kumar Saha
Journal:  J Hum Reprod Sci       Date:  2018 Jan-Mar

6.  Ultrasound Sensors for Diaphragm Motion Tracking: An Application in Non-Invasive Respiratory Monitoring.

Authors:  Amirhossein Shahshahani; Carl Laverdiere; Sharmistha Bhadra; Zeljko Zilic
Journal:  Sensors (Basel)       Date:  2018-08-09       Impact factor: 3.576

7.  Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting.

Authors:  Efrain Riveros Perez; Enoe Jimenez; Camila Albo; Yashi Sanghvi; Nianlan Yang; Alexander Rocuts
Journal:  Anesthesiol Res Pract       Date:  2019-07-21

8.  Can Smartwatch Prevent Sudden Cardiac Deaths? A Case Of Smartwatch Failure in Arrhythmogenic Right Ventricular Dysplasia.

Authors:  Sengottaian Sivakumar; Navdeep Bhatti
Journal:  Cureus       Date:  2021-06-24

9.  Nonsurgical embryo transfer device compared with surgery for embryo transfer in mice.

Authors:  Kendra H Steele; James M Hester; Barbara J Stone; Kimberly M Carrico; Brett T Spear; Angelika Fath-Goodin
Journal:  J Am Assoc Lab Anim Sci       Date:  2013-01       Impact factor: 1.706

10.  Electrocardiography versus photoplethysmography in assessment of maternal heart rate variability during labor.

Authors:  Hernâni Gonçalves; Paula Pinto; Manuela Silva; Diogo Ayres-de-Campos; João Bernardes
Journal:  Springerplus       Date:  2016-07-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.