Literature DB >> 24348796

Evaluation of acoustic radiation force impulse imaging for the clinicopathological typing of renal fibrosis.

Guanghe Cui1, Zhi Yang1, Wenxiao Zhang1, Baowei Li1, Fang Sun1, Cui Xu1, Kun Wang1.   

Abstract

This study aimed to explore the assessment value of virtual touch quantization (VTQ) for the clinicopathological typing of renal fibrosis. The quantitative detection of 76 patients with nephropathy was performed using acoustic radiation force impulse imaging (ARFI). The extent of the renal fibrosis in each patient was confirmed using ultrasound-guided biopsy pathology. The VTQ values were compared with the degree of renal fibrosis in order to analyze the correlation between them. Patients were divided pathologically into four groups, as follows: non-fibrosis (n=14), mild fibrosis (n=40), moderate fibrosis (n=21) and severe fibrosis (n=1). Compared with the non-fibrosis group, the VTQ values of the mild and moderate fibrosis groups were significantly increased (P<0.01); however, there was no significant difference between the VTQ values of the mild and moderate fibrosis groups (P>0.05). According to the receiver operating characteristic (ROC) curve, a VTQ value of renal parenchyma of >1.67 m/sec was determined to be an indicator of renal fibrosis, with a sensitivity of 86.3% and a specificity of 83.3%. VTQ technology may be significant in the assessment of the extent of renal fibrosis.

Entities:  

Keywords:  acoustic radiation force impulse imaging; fibrosis; kidney; ultrasonograph

Year:  2013        PMID: 24348796      PMCID: PMC3860982          DOI: 10.3892/etm.2013.1377

Source DB:  PubMed          Journal:  Exp Ther Med        ISSN: 1792-0981            Impact factor:   2.447


Introduction

The incidence of chronic kidney disease (CKD) is >7% per year, and is increasing annually. According to the latest data from the International Society of Nephrology (ISN), >500 million individuals worldwide suffer from various kidney diseases, and CKD, complicated by cardiovascular and cerebrovascular diseases, is the cause of mortality for >1 million individuals every year. CKD has become a serious threat to human health, following cardiovascular and cerebrovascular disease, cancer and diabetes. Patients with CKD are treated using lifelong dialysis or renal transplantation, putting a huge economic burden on families, medical institutions and society. Renal fibrosis is a pathophysiological process, in which the kidney function is gradually damaged. Further damage ultimately leads to a loss of function. The early treatment of renal fibrosis may delay or even reverse the fibrotic lesions; thus, the early diagnosis of renal fibrosis is necessary. The diagnosis of mild renal fibrosis is difficult, and biopsy remains the clear gold diagnostic standard. Acoustic radiation force impulse imaging (ARFI) is a novel technology that has been used in the differential diagnosis of liver fibrosis, and breast and thyroid benign and malignant tumors. The value of ARFI has been widely recognized, particularly for the diagnosis of liver fibrosis (1–4). However, its significance in the diagnosis of renal fibrosis has yet to be elucidated. The aim of the present study was to investigate the assessment value of virtual touch quantization (VTQ) in the pathological typing of renal fibrosis.

Patients and methods

Subjects

In total, 76 patients [43 males and 33 females; age, 11–75 years (40.37±16.13 years)], who were admitted for CKD to the Department of Nephrology Medicine, The Affiliated Hospital of Binzhou Medical College (Binzhou, China) between June 2010 and June 2012, were recruited and enrolled in this study. The extent of renal fibrosis of each patient was verified using ultrasound-guided renal biopsy pathology. This study was conducted in accordance with the Declaration of Helsinki and with approval from the Ethics Committee of Binzhou Medical College (Binzhou, China). Written informed consent was obtained from all participants.

Methods

Experiments were performed using a Siemens Acuson S2000™ color Doppler ultrasound system (Siemens Medical Solutions USA, Inc., Detroit, MI, USA), equipped with ARFI technology software and a 4C1 probe with frequencies ranging between 2.0 and 5.0 MHz and a function of VTQ determination. The patient was asked to lie in prone position and was initially examined using conventional two-dimensional ultrasound, with a longitudinal section scanning of the right kidney. The sound beam was maintained as perpendicular as possible to the kidney capsule. Subsequently the patient was asked to hold their breath, and the VTQ sampling box was placed in the right renal subcapsular parenchyma as the image stabilized in the VTQ mode. Each position of each patient was assessed five times and the average VTQ value was recorded.

Puncture biopsy

Puncture biopsy of the right inferior pole of the kidney parenchyma was performed using an 18G transfixion pin of a Bard automatic biopsy device (Bard Peripheral Vascular Inc., Tempe, AZ, USA) under ultrasonic guidance. A 2.2-cm kidney tissue biopsy was obtained and subsequently fixed in 10% formalin, prior to being sent for pathological examination. The patients were divided into four groups according to the extent of their kidney fibrosis, as follows: non-fibrosis, mild fibrosis (fibrosis extent, ≤25%), moderate fibrosis (fibrosis extent, 26–50%) and severe fibrosis (fibrosis extent, >50%).

Statistical analysis

The SPSS software program version 16.0 (SPPS Inc., Chicago, IL, USA) was used for statistical analyses. Results are presented as the mean ± standard deviation. The differences between the groups were compared using an independent sample t-test. P<0.05 was considered to indicate a statistically significant difference.

Results

The kidney tissue biopsies sent for pathological examination were classified into four groups according to the extent of fibrosis, as follows: non-fibrosis (n=14), mild fibrosis (n=40), moderate fibrosis (n=21) and severe fibrosis (n=1). The corresponding VTQ values were 1.59±0.14, 2.15±0.38, 2.29±0.53 and 2.24 m/sec, respectively (Table I). As there was only one patient in the severe fibrosis group, this group was excluded from statistical analysis. Pairwise comparisons of the non-fibrosis group with the mild and moderate fibrosis groups demonstrated that the VTQ values were significantly increased in the mild and moderate fibrosis groups (P<0.01). However, there was no significant difference between the mild and moderate fibrosis groups (P>0.05). The distribution of the VTQ values of renal parenchyma in the non-fibrosis, mild fibrosis and moderate fibrosis groups are shown in Fig. 1A. Furthermore, a receiver operating characteristic (ROC) curve was created using the VTQ values of the non-fibrosis and mild fibrosis groups. It was demonstrated that an elevated VTQ value has a certain discriminant value in the diagnosis of renal fibrosis (P<0.01, Fig. 1B). A measured VTQ value of renal parenchyma >1.67 m/sec was deemed to be a diagnostic indicator for renal fibrosis. The diagnostic sensitivity and specificity of the VTQ value were 86.3 and 83.3%, respectively.
Table I

Case numbers and VTQ values of the four groups.

GroupsCase numberVTQ value
Non-fibrosis141.59±0.14
Mild fibrosis402.15±0.38a
Moderate fibrosis212.29±0.53a
Severe fibrosis12.24

Data of VTQ values are presented as the mean ± standard deviation.

P<0.01 vs. non-fibrosis group.

VTQ, virtual touch quantization.

Figure 1

VTQ values and the ROC curve of renal parenchyma. (A) VTQ values in the non-fibrosis, mild fibrosis and moderate fibrosis groups. (B) ROC curve of the VTQ value. The VTQ value of 1.67 m/sec was determined to be a diagnostic cutoff value, with a sensitivity of 86.3% and a specificity of 83.3%. VTQ, virtual touch quantization; ROC, receiver operator curve.

Discussion

The common pathway for the development of CKD, such as primary and secondary glomerular diseases, tubular, interstitial and vascular diseases, and renal transplant chronic rejection disease, to terminal nephropathy is kidney fibrosis. The main pathological change is the absence of normal renal units, which are replaced by a large quantity of fibroblasts and myofibroblasts. The generation and accumulation of extracellular matrix, including collagen fibers and fibronectin, causes glomerulosclerosis and tubulointerstitial fibrosis and ultimately leads to the loss of kidney function (5,6). The pathological change in renal fibrosis is a gradual evolutive process from light to severe. It may be inhibited or delayed by early medication, but in severe instances it is irreversible. Therefore, the early diagnosis of renal fibrosis is likely to be beneficial for the treatment of the disease (7). At present, the clinical diagnosis of renal fibrosis is dependent on renal biopsy. However, a needle biopsy is an invasive diagnostic method with a degree of risk involved. Thus, a new, non-invasive and repeatable diagnostic method is required. Flexibility is an important physical property of biological tissues. The flexibility is not only different among various tissue types, but also in the pathological states of the same tissue. As a result of this, ultrasound elasticity imaging techniques have emerged. Ophir et al(8) first proposed the concept of elastography in 1991. Following 20 years of research and development, ultrasound elasticity imaging technology has been widely used in the differential diagnosis of benign and malignant superficial organs, such as the breast and thyroid (9–12). It has also been used in the diagnosis of liver fibrosis and cirrhosis (1–4) and in the study of various pathological types of advanced gastric cancer (13). Based on ultrasound elastography, ARFI is an established imaging technology, which includes virtual touch tissue imaging (VTI) and VTQ. VTQ is an ultrasound imaging technology for the quantitative assessment of tissue elasticity. It only produces target displacement in the region of interest, but no overall displacement, which makes up the qualitative deficiency of the past ultrasound elasticity imaging technology. VTQ is an absolute quantitative indicator that is capable of supporting tissue image contrast between patients. The ARFI technique has been shown to be capable of measuring the quantitative flexibility of abdominal organs, including the liver, kidney and stomach (13–16). A recent investigation demonstrated the application of ARFI for the study of pancreatic cystic lesions (17). VTQ technology for the diagnosis of renal fibrosis has been rarely reported and remains controversial, due to the current lack of a unified quantitative standard. Stock et al(18) hypothesized that renal parenchymal was likely to harden as a result of fibrosis and that the elasticity was likely to decrease when lesions occurred in the kidney. In addition, it was hypothesized that the VTQ value or the Young’s modulus of the renal cortex were likely to have a corresponding change that was potentially meaningful for the early diagnosis of renal fibrosis. However, Syversveen et al(19,20) reported that VTQ was not able to significantly distinguish mild fibrosis from non-fibrosis in a transplanted kidney. Furthermore, there are great differences in the VTQ values of different examiners. In this study, 76 patients with fibrosis, in whom the extent of the fibrosis had been confirmed using renal puncture biopsy, were analyzed using VTQ. It was observed that the VTQ values of patients with mild renal fibrosis were significantly higher than those of the non-fibrosis group (P<0.01). However, the VTQ values of patients with mild renal fibrosis showed no significant difference from the patients with moderate renal fibrosis. The severe fibrosis group was excluded as there was only one patient classified as having severe fibrosis, which was insufficient for a statistical analysis. According to the maximum area under the ROC curve, a VTQ value of >1.67 m/sec was determined as a diagnostic indicator of mild fibrosis of the renal cortex with a sensitivity of 86.3% and a specificity of 83.3%. The VTQ technique provides a novel reference for the clinical diagnosis of renal fibrosis. This is consistent with our assumption and results of the study of Stock et al(18). However, there are certain limitations in this study, the VTQ technique is not capable of accurately differentiating between light and moderate renal fibrisis. This may be due to the fact that there are large numbers of cross-data between light and moderate renal fibrosis. Furthermore, the classification in the present study was not entirely based on the differences between light and moderate renal fibrosis. The VTQ value measured in the non-fibrosis nephropathy group demonstrated a certain degree of overlap with that of the mild fibrosis group and the moderate fibrosis group. As the sample sizes in this study were small, particularly for the severe renal fibrosis group, further studies with a larger sample size and more data are required in order to confirm the findings of this study.
  20 in total

1.  Elastography: a quantitative method for imaging the elasticity of biological tissues.

Authors:  J Ophir; I Céspedes; H Ponnekanti; Y Yazdi; X Li
Journal:  Ultrason Imaging       Date:  1991-04       Impact factor: 1.578

2.  Preliminary results of acoustic radiation force impulse (ARFI) ultrasound imaging of breast lesions.

Authors:  Wei Meng; Guangchen Zhang; Changjun Wu; Guozhu Wu; Yan Song; Zhaoling Lu
Journal:  Ultrasound Med Biol       Date:  2011-07-20       Impact factor: 2.998

3.  Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis.

Authors:  Jérôme Boursier; Gael Isselin; Isabelle Fouchard-Hubert; Frédéric Oberti; Nina Dib; Jérôme Lebigot; Sandrine Bertrais; Yves Gallois; Paul Calès; Christophe Aubé
Journal:  Eur J Gastroenterol Hepatol       Date:  2010-09       Impact factor: 2.566

4.  Nonalcoholic fatty liver disease: US-based acoustic radiation force impulse elastography.

Authors:  Masato Yoneda; Kaori Suzuki; Shingo Kato; Koji Fujita; Yuichi Nozaki; Kunihiro Hosono; Satoru Saito; Atsushi Nakajima
Journal:  Radiology       Date:  2010-06-07       Impact factor: 11.105

5.  Assessment of renal allograft fibrosis by acoustic radiation force impulse quantification--a pilot study.

Authors:  Trygve Syversveen; Knut Brabrand; Karsten Midtvedt; Erik H Strøm; Anders Hartmann; Jarl A Jakobsen; Audun E Berstad
Journal:  Transpl Int       Date:  2010-09-02       Impact factor: 3.782

6.  Acoustic Radiation Force Impulse-Imaging for the evaluation of the thyroid gland: a limited patient feasibility study.

Authors:  Mireen Friedrich-Rust; Olga Romenski; Gesine Meyer; Nina Dauth; Katharina Holzer; Frank Grünwald; Susanne Kriener; Eva Herrmann; Stefan Zeuzem; Joerg Bojunga
Journal:  Ultrasonics       Date:  2011-07-07       Impact factor: 2.890

7.  Acoustic radiation force impulse (ARFI) imaging of the gastrointestinal tract.

Authors:  Mark L Palmeri; Kristin D Frinkley; Liang Zhai; Marcia Gottfried; Rex C Bentley; Kirk Ludwig; Kathryn R Nightingale
Journal:  Ultrason Imaging       Date:  2005-04       Impact factor: 1.578

8.  Acoustic radiation force impulse (ARFI) ultrasound imaging of pancreatic cystic lesions.

Authors:  M D'Onofrio; A Gallotti; R Salvia; P Capelli; R Pozzi Mucelli
Journal:  Eur J Radiol       Date:  2010-07-14       Impact factor: 3.528

9.  Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis.

Authors:  Carmen Fierbinteanu-Braticevici; Dan Andronescu; Radu Usvat; Dragos Cretoiu; Cristian Baicus; Gabriela Marinoschi
Journal:  World J Gastroenterol       Date:  2009-11-28       Impact factor: 5.742

10.  Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study.

Authors:  Hirokazu Takahashi; Naofumi Ono; Yuichiro Eguchi; Takahisa Eguchi; Yoichiro Kitajima; Yasunori Kawaguchi; Shunya Nakashita; Iwata Ozaki; Toshihiko Mizuta; Shuji Toda; Sho Kudo; Atsushi Miyoshi; Kohji Miyazaki; Kazuma Fujimoto
Journal:  Liver Int       Date:  2009-10-27       Impact factor: 5.828

View more
  15 in total

1.  Diagnostic utility of Acoustic Radiation Force Impulse (ARFI) imaging in primary Sjoegren`s syndrome.

Authors:  Andreas Knopf; Benedikt Hofauer; Klaus Thürmel; Reinhard Meier; Konrad Stock; Murat Bas; Naglaa Manour
Journal:  Eur Radiol       Date:  2015-04-11       Impact factor: 5.315

2.  ARFI shear-wave elastography with simulation of acute urinary tract obstruction in an ex vivo porcine kidney model.

Authors:  Jens Muttray; Arianeb Mehrabi; Mohammadreza Hafezi; Arash Saffari; Thi Thanh Tam Bui-Ta; Jochen Meyburg; Elke Wühl; Jens Peter Schenk
Journal:  Diagn Interv Radiol       Date:  2018-09       Impact factor: 2.630

Review 3.  Causal contributors to tissue stiffness and clinical relevance in urology.

Authors:  Laura Martinez-Vidal; Valentina Murdica; Chiara Venegoni; Filippo Pederzoli; Marco Bandini; Andrea Necchi; Andrea Salonia; Massimo Alfano
Journal:  Commun Biol       Date:  2021-08-26

4.  Effect of liposomal local therapy on salivary glands in acoustic radiation force impulse imaging in Sjögren's syndrome.

Authors:  Benedikt Hofauer; Naglaa Mansour; Clemens Heiser; Ulrich Straßen; Murat Bas; Andreas Knopf
Journal:  Clin Rheumatol       Date:  2016-08-29       Impact factor: 2.980

Review 5.  Principles of ultrasound elastography.

Authors:  Arinc Ozturk; Joseph R Grajo; Manish Dhyani; Brian W Anthony; Anthony E Samir
Journal:  Abdom Radiol (NY)       Date:  2018-04

6.  Renal shear wave elastography for the assessment of nephron hypertrophy: a cross-sectional study in chronic kidney disease.

Authors:  Takuji Iyama; Tomoaki Takata; Masahiko Koda; Satoko Fukuda; Shotaro Hoi; Yukari Mae; Takeaki Fukui; Chishio Munemura; Hajime Isomoto
Journal:  J Med Ultrason (2001)       Date:  2018-02-06       Impact factor: 1.314

7.  Shear wave elastography in the evaluation of renal parenchymal stiffness in patients with chronic kidney disease.

Authors:  Sook Sam Leong; Jeannie Hsiu Ding Wong; Mohammad Nazri Md Shah; Anushya Vijayananthan; Maisarah Jalalonmuhali; Kwan Hoong Ng
Journal:  Br J Radiol       Date:  2018-06-21       Impact factor: 3.039

8.  Acoustic radiation force impulse imaging for non-invasive assessment of renal histopathology in chronic kidney disease.

Authors:  Qiao Hu; Xiao-Yan Wang; Hong-Guang He; Hai-Ming Wei; Li-Ke Kang; Gui-Can Qin
Journal:  PLoS One       Date:  2014-12-29       Impact factor: 3.240

Review 9.  ARFI: from basic principles to clinical applications in diffuse chronic disease-a review.

Authors:  Costanza Bruno; Salvatore Minniti; Alessandra Bucci; Roberto Pozzi Mucelli
Journal:  Insights Imaging       Date:  2016-08-23

Review 10.  Applications of acoustic radiation force impulse quantification in chronic kidney disease: a review.

Authors:  Liang Wang
Journal:  Ultrasonography       Date:  2016-07-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.