Literature DB >> 29869920

Shear wave elastography in the evaluation of renal parenchymal stiffness in patients with chronic kidney disease.

Sook Sam Leong1,2, Jeannie Hsiu Ding Wong1,3, Mohammad Nazri Md Shah1,3, Anushya Vijayananthan1,3, Maisarah Jalalonmuhali4, Kwan Hoong Ng1,3.   

Abstract

OBJECTIVE: To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR).
METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.
RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity).
CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.

Entities:  

Mesh:

Year:  2018        PMID: 29869920      PMCID: PMC6223162          DOI: 10.1259/bjr.20180235

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  27 in total

1.  Relationship between the estimated glomerular filtration rate and kidney shear wave speed values assessed by acoustic radiation force impulse elastography: a pilot study.

Authors:  Flaviu Bob; Simona Bota; Ioan Sporea; Roxana Sirli; Alina Popescu; Adalbert Schiller
Journal:  J Ultrasound Med       Date:  2015-04       Impact factor: 2.153

2.  Strain wave elastography for evaluation of renal parenchyma in chronic kidney disease.

Authors:  M S Menzilcioglu; M Duymus; S Citil; S Avcu; G Gungor; T Sahin; S N Boysan; O Altunoren; A Sarica
Journal:  Br J Radiol       Date:  2015-03-25       Impact factor: 3.039

3.  Can renal sonography be a reliable diagnostic tool in the assessment of chronic kidney disease?

Authors:  Gaetano Lucisano; Nicolino Comi; Elena Pelagi; Paola Cianfrone; Laura Fuiano; Giorgio Fuiano
Journal:  J Ultrasound Med       Date:  2015-02       Impact factor: 2.153

4.  Research on pediatric glomerular disease and normal kidney with shear wave based elastography point quantification.

Authors:  Bin Xu; Guoping Jiang; Jingjing Ye; Jin He; Wangfang Xie
Journal:  Jpn J Radiol       Date:  2016-09-22       Impact factor: 2.374

5.  The role of ultrasonography in the study of medical nephropathy.

Authors:  F Fiorini; L Barozzi
Journal:  J Ultrasound       Date:  2007-11-05

Review 6.  Renal ultrasound elastography.

Authors:  N Grenier; J-L Gennisson; F Cornelis; Y Le Bras; L Couzi
Journal:  Diagn Interv Imaging       Date:  2013-04-06       Impact factor: 4.026

7.  Acoustic radiation force impulse imaging for non-invasive assessment of renal histopathology in chronic kidney disease.

Authors:  Qiao Hu; Xiao-Yan Wang; Hong-Guang He; Hai-Ming Wei; Li-Ke Kang; Gui-Can Qin
Journal:  PLoS One       Date:  2014-12-29       Impact factor: 3.240

8.  Shear wave elastography in chronic kidney disease: a pilot experience in native kidneys.

Authors:  Anthony E Samir; Andrew S Allegretti; Qingli Zhu; Manish Dhyani; Arash Anvari; Dorothy A Sullivan; Caitlin A Trottier; Sarah Dougherty; Winfred W Williams; Jodie L Babitt; Julia Wenger; Ravi I Thadhani; Herbert Y Lin
Journal:  BMC Nephrol       Date:  2015-07-31       Impact factor: 2.388

9.  Evaluation of acoustic radiation force impulse imaging for the clinicopathological typing of renal fibrosis.

Authors:  Guanghe Cui; Zhi Yang; Wenxiao Zhang; Baowei Li; Fang Sun; Cui Xu; Kun Wang
Journal:  Exp Ther Med       Date:  2013-10-31       Impact factor: 2.447

10.  Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys.

Authors:  Beomseok Sohn; Myung-Joon Kim; Sang Won Han; Young Jae Im; Mi-Jung Lee
Journal:  Ultrasonography       Date:  2014-02-26
View more
  9 in total

Review 1.  Novel Uses of Ultrasound to Assess Kidney Mechanical Properties.

Authors:  Matthew W Urban; Andrew D Rule; Thomas D Atwell; Shigao Chen
Journal:  Kidney360       Date:  2021-07-01

Review 2.  Causal contributors to tissue stiffness and clinical relevance in urology.

Authors:  Laura Martinez-Vidal; Valentina Murdica; Chiara Venegoni; Filippo Pederzoli; Marco Bandini; Andrea Necchi; Andrea Salonia; Massimo Alfano
Journal:  Commun Biol       Date:  2021-08-26

3.  Shear wave elastography in early diabetic kidney disease.

Authors:  Ruken Yuksekkaya; Fatih Celikyay; Mehmet Yuksekkaya; Faruk Kutluturk
Journal:  Rev Assoc Med Bras (1992)       Date:  2022-05-13       Impact factor: 1.712

4.  Do deep inspiration breath-holds and free-breathing affect pancreatic tissue stiffness in shear wave elastography?

Authors:  Mustafa Kaya; Enes Gürün
Journal:  Abdom Radiol (NY)       Date:  2022-05-04

Review 5.  Kidney Ultrasound for Nephrologists: A Review.

Authors:  Rohit K Singla; Matthew Kadatz; Robert Rohling; Christopher Nguan
Journal:  Kidney Med       Date:  2022-04-07

6.  Shear wave elastography evaluation of liver, pancreas, spleen and kidneys in patients with familial mediterranean fever and amyloidosis.

Authors:  Zuhal Bayramoglu; Zeynep Nur Akyol Sari; Oya Koker; Ibrahim Adaletli; Rukiye Eker Omeroglu
Journal:  Br J Radiol       Date:  2021-09-14       Impact factor: 3.039

7.  Shear wave elastography and Doppler ultrasound in kidney transplant recipients.

Authors:  Luana Marinho Gonçalves; Gabriele Carra Forte; Tiago Garcia Holz; Lucas Lobraico Libermann; Carlos Eduardo Poli de Figueiredo; Bruno Hochhegger
Journal:  Radiol Bras       Date:  2022 Jan-Feb

8.  Shear Wave Elastography in the Evaluation of Renal Parenchymal Stiffness in Patients With Chronic Kidney Disease: A Meta-Analysis.

Authors:  Xian Ling Mo; Hui Yan Meng; Yan Yan Wu; Xue Yan Wei; Zong Ke Li; Su Qin Yang
Journal:  J Clin Med Res       Date:  2022-02-24

9.  Shear-Wave Elastography Variability Analysis and Relation with Kidney Allograft Dysfunction: A Single-Center Study.

Authors:  Sorana D Bolboacă; Florin Ioan Elec; Alina Daciana Elec; Adriana Milena Muntean; Mihai Adrian Socaciu; Gheorghita Iacob; Răzvan Zaro; Alexandra-Ioana Andrieș; Ramona Maria Bădulescu; Radu Mihai Ignat; Mihaela Iancu; Radu Ion Badea
Journal:  Diagnostics (Basel)       Date:  2020-01-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.