| Literature DB >> 24341288 |
Chieko Matsubara, Joseph Green, Linda Teresa Astorga, Edgardo L Daya, Honorato C Jervoso, Edgardo M Gonzaga, Masamine Jimba1.
Abstract
BACKGROUND: Satisfaction is an important indicator of the quality of care during childbirth. Previous research found that a good environment at a health facility can increase the number of deliveries at that facility. In contrast, an unsatisfying childbirth experience could cause postpartum mental disorder. Therefore it is important to measure mothers' satisfaction with their childbirth experiences. We tested whether the eight-item Client Satisfaction Questionnaire (CSQ-8) provided useful information about satisfaction with childbirth-related care. The government of the Philippines promotes childbirth at health facilities, so we tested the CSQ-8 in the Philippine cities of Ormoc and Palo.Entities:
Mesh:
Year: 2013 PMID: 24341288 PMCID: PMC3878559 DOI: 10.1186/1471-2393-13-235
Source DB: PubMed Journal: BMC Pregnancy Childbirth ISSN: 1471-2393 Impact factor: 3.007
Figure 1Distribution of CSQ-8 scores for the last delivery, by language (1-a: Cebuano, 1-b: Waray).
Demographic characteristics of participants, and correlations with CSQ-8 scores
| | | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Age | Mean (SD) | 30.5 | (6.7) | 0.07¶ | 0.49 | 31.6 | (5.3) | 0.05¶ | 0.64 |
| Number of birth order before the last delivery | Mean (SD) | 2.9 | (2.4) | 0.06¶ | 0.54 | 3.2 | (2.0) | 0.03¶ | 0.82 |
| Yes | 46 | 48.4 | 0.45§ | 0.45 | 35 | 55.6 | 0.11§ | 0.40 | |
| | No | 49 | 51.6 | | | 28 | 44.4 | | |
| Occupation | Housewife | 90 | 90.9 | 0.68§ | 0.68 | | | | |
| Others | 9 | 9.1 | |||||||
n: number of participants, r: correlation coefficient, p: p-value, ¶: Spearman’s rank-order correlation, §: point-biserial correlation, †: total numbers of participants vary due to missing data. For Waray participants, we could not find characteristics of all respondents from the medical records, because in some cases the information given in the interview did not match that written in the medical record (maiden name or married name).
Internal-consistency reliability of the Cebuano CSQ-8 (n = 100)
| | ||||
|---|---|---|---|---|
| | ||||
| 1. Quality of service | 0.54 | 0.84 | 0.59 | 0.85 |
| 2. Kind of service | 0.61 | 0.83 | 0.57 | 0.85 |
| 3. Met need | 0.63 | 0.83 | 0.61 | 0.84 |
| 4. Recommend to a friend | 0.58 | 0.84 | 0.68 | 0.84 |
| 5. Amount of help | 0.68 | 0.82 | 0.66 | 0.84 |
| 6. Deal with problems | 0.53 | 0.84 | 0.60 | 0.85 |
| 7. Overall satisfaction | 0.67 | 0.83 | 0.65 | 0.84 |
| 8. Come back | 0.52 | 0.84 | 0.64 | 0.85 |
| Suitability for factor analysis | | | | |
| | Kaiser-Meyer-Olkin value = 0.82 | | Kaiser-Meyer-Olkin value = 0.85 | |
| Bartlett’s Test of Sphericity: | Bartlett’s Test of Sphericity: | |||
Component matrix for the Cebuano CSQ-8 for the last baby delivery (n = 100)
| 1. Quality of service | 0.650 | -0.174 | 0.453 | -0.520 | 0.069 | -0.031 | 0.210 | -0.147 |
| 2. Kind of service | 0.718 | 0.100 | -0.398 | -0.424 | 0.186 | 0.123 | -0.141 | 0.258 |
| 3. Met needs | 0.738 | -0.111 | -0.344 | 0.137 | -0.339 | 0.041 | 0.433 | 0.045 |
| 4. Recommend to a friend | 0.688 | 0.545 | -0.194 | 0.145 | 0.300 | 0.007 | 0.049 | -0.280 |
| 5. Amount of help | 0.780 | -0.107 | -0.072 | -0.045 | -0.439 | -0.007 | -0.381 | -0.186 |
| 6. Deal with problems | 0.639 | -0.518 | 0.094 | 0.323 | 0.295 | 0.346 | -0.062 | -0.016 |
| 7. Overall satisfaction | 0.766 | -0.162 | 0.068 | 0.205 | 0.161 | -0.545 | -0.051 | 0.121 |
| 8. Come back | 0.624 | 0.460 | 0.517 | 0.183 | -0.166 | 0.159 | -0.021 | 0.213 |
Figure 2Scree plot of the Cebuano CSQ-8 for the last delivery.
Internal-consistency reliability of the Waray CSQ-8 (n = 106)
| | ||||
|---|---|---|---|---|
| | ||||
| 1. Quality of service | 0.62 | 0.82 | 0.60 | 0.85 |
| 2. Kind of service | 0.46 | 0.84 | 0.52 | 0.86 |
| 3. Met need | 0.64 | 0.81 | 0.61 | 0.85 |
| 4. Recommend to a friend | 0.58 | 0.82 | 0.67 | 0.85 |
| 5. Amount of help | 0.63 | 0.82 | 0.73 | 0.84 |
| 6. Deal with problems | 0.62 | 0.82 | 0.59 | 0.86 |
| 7. Overall satisfaction | 0.58 | 0.83 | 0.58 | 0.86 |
| 8. Come back | 0.53 | 0.83 | 0.68 | 0.84 |
| Suitability of factor analysis | | | | |
| | Kaiser-Meyer-Olkin value = 0.85 | | Kaiser-Meyer-Olkin value = 0.86 | |
| Bartlett’s Test of Sphericity: | Bartlett’s Test of Sphericity: | |||
Component matrix for the Waray CSQ-8 for the last baby delivery (n = 106)
| 1. Quality of service | 0.739 | 0.138 | -0.124 | -0.338 | 0.417 | -0.303 | 0.128 | -0.149 |
| 2. Kind of service | 0.533 | 0.291 | 0.775 | -0.081 | -0.017 | 0.132 | 0.071 | -0.039 |
| 3. Met needs | 0.756 | 0.204 | -0.299 | 0.050 | -0.264 | 0.181 | 0.438 | 0.007 |
| 4. Recommend to a friend | 0.714 | -0.556 | -0.003 | -0.025 | -0.128 | 0.153 | -0.123 | -0.355 |
| 5. Amount of help | 0.728 | 0.126 | 0.052 | 0.416 | -0.252 | -0.449 | -0.119 | -0.004 |
| 6. Deal with problems | 0.732 | 0.126 | -0.138 | -0.493 | -0.229 | 0.050 | -0.298 | 0.205 |
| 7. Overall satisfaction | 0.696 | 0.301 | -0.176 | 0.384 | 0.325 | 0.301 | -0.223 | 0.022 |
| 8. Come back | 0.667 | -0.612 | 0.139 | 0.096 | 0.175 | -0.018 | 0.125 | 0.325 |
Figure 3Scree plot of the Waray CSQ-8 for the last delivery.
Comparison of CSQ-8 satisfaction scores between home delivery and facility delivery (the place of 2nd-to-last delivery)
| Cebuano | Home | 51 | 20.0 | 36.1 | -5.08 | <0.001 | 0.51 | 51 | 27.0 | 51.5 | -0.35 | 0.72 | 0.04 |
| (n = 100) | Hospital | 49 | 27.0 | 65.5 | | | | 49 | 26.0 | 49.5 | | | |
| Waray | Home | 54 | 22.0 | 36.9 | -5.69 | <0.001 | 0.55 | 51 | 28.0 | 56.4 | -1.30 | 0.20 | 0.13 |
| (n = 106) | Hospital | 52 | 28.0 | 70.8 | 53 | 27.0 | 48.8 | ||||||