Literature DB >> 24333021

Experience with the CyberKnife for intracranial stereotactic radiosurgery: analysis of dosimetry indices.

Alejandro Floriano1, Iciar Santa-Olalla2, Alberto Sanchez-Reyes2.   

Abstract

We evaluated coverage, dose homogeneity, dose conformity, and dose gradient in CyberKnife VSI treatment plans. Several dosimetric indices were calculated, and the results were compared with those of previous publications. The effect of target volume on the radiosurgical treatment indices selected was also investigated. The study population comprised the first 40 patients treated at our department from March 2011 to September 2012. Dosimetric indices were calculated and compared with published results for other frame-based and frameless intracranial stereotactic radiotherapy techniques. A comparison of the indices confirmed the ability of the CyberKnife VSI system to provide very high-quality dosing plans. The results were independent of target volume for coverage, homogeneity, and dose conformity. However, a dependence on target volume was observed for the dose-gradient indices analyzed. Based on the indices proposed, CyberKnife provides very good treatment plans and compares favorably with other techniques in most cases. However, greater consensus on the radiosurgery indices calculated would be desirable to facilitate comparison of the various techniques or the same techniques when applied by different users.
Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CyberKnife; Dosimetric indices; Frameless; Treatment planning

Mesh:

Year:  2013        PMID: 24333021     DOI: 10.1016/j.meddos.2013.08.005

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  The impact of target positioning error and tumor size on radiobiological parameters in robotic stereotactic radiosurgery for metastatic brain tumors.

Authors:  Takeshi Takizawa; Satoshi Tanabe; Hisashi Nakano; Satoru Utsunomiya; Madoka Sakai; Katsuya Maruyama; Shigekazu Takeuchi; Toshimichi Nakano; Atsushi Ohta; Motoki Kaidu; Hiroyuki Ishikawa; Kiyoshi Onda
Journal:  Radiol Phys Technol       Date:  2022-03-07

2.  Resection cavity radiosurgery for intracranial metastases: a review of the literature.

Authors:  Ying Zhang; Eric L Chang
Journal:  J Radiosurg SBRT       Date:  2014

3.  Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery.

Authors:  Jessica Molinier; Christine Kerr; Sebastien Simeon; Norbert Ailleres; Marie Charissoux; David Azria; Pascal Fenoglietto
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  A Dose-Volume Response Model for Brain Metastases Treated With Frameless Single-Fraction Robotic Radiosurgery: Seeking to Better Predict Response to Treatment.

Authors:  Mark J Amsbaugh; Mehran B Yusuf; Jeremy Gaskins; Anthony E Dragun; Neal Dunlap; Timothy Guan; Shiao Woo
Journal:  Technol Cancer Res Treat       Date:  2016-12-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.