Literature DB >> 23807573

Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: a simulation study.

Ryan M Jones1, Meaghan A O'Reilly, Kullervo Hynynen.   

Abstract

The feasibility of transcranial passive acoustic mapping with hemispherical sparse arrays (30 cm diameter, 16 to 1372 elements, 2.48 mm receiver diameter) using CT-based aberration corrections was investigated via numerical simulations. A multi-layered ray acoustic transcranial ultrasound propagation model based on CT-derived skull morphology was developed. By incorporating skull-specific aberration corrections into a conventional passive beamforming algorithm (Norton and Won 2000 IEEE Trans. Geosci. Remote Sens. 38 1337-43), simulated acoustic source fields representing the emissions from acoustically-stimulated microbubbles were spatially mapped through three digitized human skulls, with the transskull reconstructions closely matching the water-path control images. Image quality was quantified based on main lobe beamwidths, peak sidelobe ratio, and image signal-to-noise ratio. The effects on the resulting image quality of the source's emission frequency and location within the skull cavity, the array sparsity and element configuration, the receiver element sensitivity, and the specific skull morphology were all investigated. The system's resolution capabilities were also estimated for various degrees of array sparsity. Passive imaging of acoustic sources through an intact skull was shown possible with sparse hemispherical imaging arrays. This technique may be useful for the monitoring and control of transcranial focused ultrasound (FUS) treatments, particularly non-thermal, cavitation-mediated applications such as FUS-induced blood-brain barrier disruption or sonothrombolysis, for which no real-time monitoring techniques currently exist.

Entities:  

Mesh:

Year:  2013        PMID: 23807573      PMCID: PMC3785015          DOI: 10.1088/0031-9155/58/14/4981

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  71 in total

Review 1.  Time-reversal acoustics in biomedical engineering.

Authors:  Mathias Fink; Gabriel Montaldo; Mickael Tanter
Journal:  Annu Rev Biomed Eng       Date:  2003       Impact factor: 9.590

2.  Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans.

Authors:  J F Aubry; M Tanter; M Pernot; J L Thomas; M Fink
Journal:  J Acoust Soc Am       Date:  2003-01       Impact factor: 1.840

3.  Spatiotemporal monitoring of high-intensity focused ultrasound therapy with passive acoustic mapping.

Authors:  Carl R Jensen; Robert W Ritchie; Miklós Gyöngy; James R T Collin; Tom Leslie; Constantin-C Coussios
Journal:  Radiology       Date:  2011-10-24       Impact factor: 11.105

4.  Transcranial ultrasound focus reconstruction with phase and amplitude correction.

Authors:  Jason White; Greg T Clement; Kullervo Hynynen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-09       Impact factor: 2.725

5.  Sparse 2-D array design for real time rectilinear volumetric imaging.

Authors:  J T Yen; J P Steinberg; S W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

6.  Temporal and spatial detection of HIFU-induced inertial and hot-vapor cavitation with a diagnostic ultrasound system.

Authors:  Caleb H Farny; R Glynn Holt; Ronald A Roy
Journal:  Ultrasound Med Biol       Date:  2008-12-24       Impact factor: 2.998

7.  High power transcranial beam steering for ultrasonic brain therapy.

Authors:  M Pernot; J F Aubry; M Tanter; J L Thomas; M Fink
Journal:  Phys Med Biol       Date:  2003-08-21       Impact factor: 3.609

8.  Passive cavitation imaging with ultrasound arrays.

Authors:  Vasant A Salgaonkar; Saurabh Datta; Christy K Holland; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2009-12       Impact factor: 1.840

9.  Simulations and measurements of transcranial low-frequency ultrasound therapy: skull-base heating and effective area of treatment.

Authors:  Aki Pulkkinen; Yuexi Huang; Junho Song; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2011-07-06       Impact factor: 3.609

10.  Thin-film sparse boundary array design for passive acoustic mapping during ultrasound therapy.

Authors:  Christian M Coviello; Richard J Kozick; Andrew Hurrell; Penny Probert Smith; Constantin-C Coussios
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

View more
  31 in total

1.  Comparison of analytical and numerical approaches for CT-based aberration correction in transcranial passive acoustic imaging.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2015-11-25       Impact factor: 3.609

Review 2.  Therapeutic strategies to improve drug delivery across the blood-brain barrier.

Authors:  Tej D Azad; James Pan; Ian D Connolly; Austin Remington; Christy M Wilson; Gerald A Grant
Journal:  Neurosurg Focus       Date:  2015-03       Impact factor: 4.047

3.  Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

Authors:  Costas D Arvanitis; Nathan McDannold
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

4.  A super-resolution ultrasound method for brain vascular mapping.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 5.  Drug delivery across the blood-brain barrier using focused ultrasound.

Authors:  Alison Burgess; Kullervo Hynynen
Journal:  Expert Opin Drug Deliv       Date:  2014-03-20       Impact factor: 6.648

6.  Transcranial cavitation detection in primates during blood-brain barrier opening--a performance assessment study.

Authors:  Shih-Ying Wu; Yao-Sheng Tung; Fabrice Marquet; Matthew Downs; Carlos Sanchez; Cherry Chen; Vincent Ferrera; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-06       Impact factor: 2.725

7.  Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array.

Authors:  Meaghan A O'Reilly; Ryan M Jones; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2014-04       Impact factor: 4.538

8.  Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections.

Authors:  Ryan M Jones; Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 9.  Advances in acoustic monitoring and control of focused ultrasound-mediated increases in blood-brain barrier permeability.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Br J Radiol       Date:  2019-02-28       Impact factor: 3.039

Review 10.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.