Literature DB >> 24318404

Computational fluid dynamics analysis of the pump parameters in the helical flow pump.

Kyohei Hosoda1, Kohei Ishii, Takashi Isoyama, Itsuro Saito, Yusuke Inoue, Kouki Ariyoshi, Toshiya Ono, Hidemoto Nakagawa, Kou Imachi, Hiroshi Kumagai, Yusuke Abe.   

Abstract

The helical flow pump (HFP) was invented to develop a total artificial heart at the University of Tokyo in 2005. The HFP consists of the multi-vane impeller involving rotor magnets, a motor stator and pump housing having double-helical volutes. To investigate the characteristics of the HFP, computational fluid dynamics analysis was performed. Validation of the computational model was performed with the data of the actual pump. A control computational model in which the vane area corresponded approximately to that of the actual pump was designed for the parametric study. The parametric study was performed varying the vane height, vane width and helical volute pitch. When the vane height was varied from 0.5 to 1.5 times that of the control computational model, the H-Q (pressure head vs. flow) and efficiency curves were translated in parallel with the vane height. When the vane height was two and three times that of the control computational model, the profile of these curves changed. From the results, the best proportion for the vane was considered to be a vane height between 1.5 and 2 times the vane width. The effect of vane width was not very strong compared to that of the vane height. A similar tendency in vane height was observed by varying the helical volute pitch. The best helical volute-pitch size is considered to be between 1.5 and 2 times the vane width. Although further study is necessary to determine the best values for these parameters, the characteristics of the pump parameters in the HFP could be approximately clarified.

Mesh:

Year:  2013        PMID: 24318404     DOI: 10.1007/s10047-013-0739-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  14 in total

1.  Development status of Terumo implantable left ventricular assist system.

Authors:  C Nojiri; T Kijima; J Maekawa; K Horiuchi; T Kido; T Sugiyama; T Mori; N Sugiura; T Asada; W Umemura; T Ozaki; M Suzuki; T Akamatsu; S Westaby; T Katsumata; S Saito
Journal:  Artif Organs       Date:  2001-05       Impact factor: 3.094

2.  Design concepts and principle of operation of the HeartWare ventricular assist system.

Authors:  Jeffrey A Larose; Daniel Tamez; Michael Ashenuga; Carlos Reyes
Journal:  ASAIO J       Date:  2010 Jul-Aug       Impact factor: 2.872

3.  Axial magnetic bearing development for the BiVACOR rotary BiVAD/TAH.

Authors:  Nicholas A Greatrex; Daniel L Timms; Nobuyuki Kurita; Edward W Palmer; Toru Masuzawa
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-09       Impact factor: 4.538

4.  Initial clinical experience of total cardiac replacement with dual HeartMate-II axial flow pumps for severe biventricular heart failure.

Authors:  Matthias Loebe; Brian Bruckner; Michael J Reardon; Erika van Doorn; Jerry Estep; Igor Gregoric; Faisel Masud; William Cohn; Tadashi Motomura; Guillermo Torre-Amione; O H Frazier
Journal:  Methodist Debakey Cardiovasc J       Date:  2011 Jan-Mar

5.  The helical flow total artificial heart: implantation in goats.

Authors:  Yusuke Abe; Kohei Ishii; Takashi Isoyama; Itsuro Saito; Yusuke Inoue; Masami Sato; Shintaro Hara; Kyohei Hosoda; Koki Ariyoshi; Hidemoto Nakagawa; Toshiya Ono; Kyoko Fukazawa; Kazuhiko Ishihara; Kou Imachi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

6.  EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

Authors:  Kenji Yamazaki; Shinichiro Kihara; Takehide Akimoto; Osamu Tagusari; Akihiko Kawai; Mitsuo Umezu; Jun Tomioka; Robert L Kormos; Bartley P Griffith; Hiromi Kurosawa
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2002-11

7.  First clinical experience with the Incor left ventricular assist device.

Authors:  Christof Schmid; Tonny D T Tjan; Christian Etz; Christoph Schmidt; Frauke Wenzelburger; Markus Wilhelm; Markus Rothenburger; Gabi Drees; Hans H Scheld
Journal:  J Heart Lung Transplant       Date:  2005-09       Impact factor: 10.247

8.  A miniature implantable axial flow ventricular assist device.

Authors:  M E DeBakey
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

Review 9.  Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults.

Authors:  Yulong Guan; Tushar Karkhanis; Shigang Wang; Alan Rider; Steven C Koenig; Mark S Slaughter; Aly El Banayosy; Akif Undar
Journal:  Artif Organs       Date:  2010-05-21       Impact factor: 3.094

10.  An innovative, sensorless, pulsatile, continuous-flow total artificial heart: device design and initial in vitro study.

Authors:  Kiyotaka Fukamachi; David J Horvath; Alex L Massiello; Hideyuki Fumoto; Tetsuya Horai; Santosh Rao; Leonard A R Golding
Journal:  J Heart Lung Transplant       Date:  2009-09-26       Impact factor: 10.247

View more
  1 in total

Review 1.  Artificial hearts-recent progress: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2017-06-15       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.