Development status of Terumo implantable left ventricular assist system.

C Nojiri1, T Kijima, J Maekawa, K Horiuchi, T Kido, T Sugiyama, T Mori, N Sugiura, T Asada, W Umemura, T Ozaki, M Suzuki, T Akamatsu, S Westaby, T Katsumata, S Saito.   

Abstract

We have been developing an implantable left ventricular assist system (T-ILVAS) featuring a magnetically suspended centrifugal pump (MSCP) since 1995. In vitro and in vivo studies using a prototype MSCP composed of a polycarbonate housing and impeller (196 ml) have demonstrated long-term durability and excellent blood compatibility for up to 864 days, and excellent stability of the magnetic bearing of the MSCP. These preliminary results strongly suggested that the magnetic bearing of the MSCP is reliable and is a most feasible mechanism for a long-term circulatory assist device. We have recently devised a clinical version pump made of titanium (180 ml) with a new position sensor mechanism and a wearable controller with batteries. Cadaver fit study confirmed that the Type IV pump could be implanted in a small patient with a body surface area as small as 1.3. The in vitro performance tests of the Type IV pump demonstrated excellent hydrodynamic performances with an acceptable hemolysis rate. New position sensors for the titanium housing showed more uniform sensor outputs of a magnetic bearing than in the prototype polycarbonate pump. The Type IV pump then was evaluated in vivo in 6 sheep at the Oxford Heart Centre. Four sheep were electively sacrificed at 3 months and were allowed to survive for more than 6 months for long-term evaluation. In this particular series of experiments, no anticoagulant/antiplatelet regimen was utilized except for a bolus dose of heparin during surgery. There was a left ventricular mural thrombi around the inflow cannula in 1 sheep. Otherwise, there was no mechanical failure nor sign of thromboembolism throughout the study.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11403674     DOI: 10.1046/j.1525-1594.2001.025005411.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  11 in total

Review 1.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

Review 2.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

Review 3.  Development of mechanical circulatory support devices at the University of Tokyo.

Authors:  Yusuke Abe; Takashi Isoyama; Itsuro Saito; Shuichi Mochizuki; Minoru Ono; Hidemoto Nakagawa; Noriyuki Taniguchi; Norihiko Mitsumune; Ayaka Sugino; Mie Mitsui; Koki Takiura; Toshiya Ono; Akimasa Kouno; Tsuneo Chinzei; Shinichi Takamoto; Kou Imachi
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

4.  Computational fluid dynamics analysis of the pump parameters in the helical flow pump.

Authors:  Kyohei Hosoda; Kohei Ishii; Takashi Isoyama; Itsuro Saito; Yusuke Inoue; Kouki Ariyoshi; Toshiya Ono; Hidemoto Nakagawa; Kou Imachi; Hiroshi Kumagai; Yusuke Abe
Journal:  J Artif Organs       Date:  2013-12-07       Impact factor: 1.731

5.  Continuous-flow total artificial heart supports long-term survival of a calf.

Authors:  O H Frazier; William E Cohn; Egemen Tuzun; Jo Anna Winkler; Igor D Gregoric
Journal:  Tex Heart Inst J       Date:  2009

6.  Automatic calibration of the inlet pressure sensor for the implantable continuous-flow ventricular assist device.

Authors:  Wei Shi; Itsuro Saito; Takashi Isoyama; Hidemoto Nakagawa; Yusuke Inoue; Toshiya Ono; Akimasa Kouno; Kou Imachi; Yusuke Abe
Journal:  J Artif Organs       Date:  2011-03-05       Impact factor: 1.731

7.  The helical flow pump with a hydrodynamic levitation impeller.

Authors:  Yusuke Abe; Kohei Ishii; Takashi Isoyama; Itsuro Saito; Yusuke Inoue; Toshiya Ono; Hidemoto Nakagawa; Emiko Nakano; Kyoko Fukazawa; Kazuhiko Ishihara; Kazuyoshi Fukunaga; Minoru Ono; Kou Imachi
Journal:  J Artif Organs       Date:  2012-08-28       Impact factor: 1.731

8.  Development and evaluation of endurance test system for ventricular assist devices.

Authors:  Hirohito Sumikura; Akihiko Homma; Kentaro Ohnuma; Yoshiyuki Taenaka; Yoshiaki Takewa; Hiroshi Mukaibayashi; Kazuo Katano; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-02-12       Impact factor: 1.731

9.  A nonpulsatile total artificial heart with 1/R control.

Authors:  Yusuke Abe; Itsuro Saito; Takashi Isoyama; Hidekazu Miura; Wei Shi; Sachiko Yamaguchi; Yusuke Inoue; Hidemoto Nakagawa; Minoru Ono; Ayumi Kishi; Toshiya Ono; Akimasa Kouno; Tsuneo Chinzei; Kou Imachi
Journal:  J Artif Organs       Date:  2008-12-17       Impact factor: 1.731

10.  First Turkish experience with the MicroMed DeBakey VAD.

Authors:  Deniz Suha Kucukaksu; Erol Sener; Akif Undar; George P Noon; Oguz Tasdemir
Journal:  Tex Heart Inst J       Date:  2003
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.