Literature DB >> 24292854

Influence of the washing program on the blood processing performance of a continuous autotransfusion device.

Chiyul Yoon1, Seungwoo Noh, Jung Chan Lee, Sung Ho Ko, Wonsik Ahn, Hee Chan Kim.   

Abstract

The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24292854     DOI: 10.1007/s10047-013-0745-x

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  11 in total

1.  Fat elimination from autologous blood.

Authors:  M Booke; H Van Aken; M Storm; F Fritzsche; S Wirtz; F Hinder
Journal:  Anesth Analg       Date:  2001-02       Impact factor: 5.108

2.  Intraoperative autotransfusion in small children: an in vitro investigation to study its feasibility.

Authors:  M Booke; O Hagemann; H Van Aken; M Erren; J Wüllenweber; H G Bone
Journal:  Anesth Analg       Date:  1999-04       Impact factor: 5.108

3.  Processing scavenged blood with a cell saver reduces cerebral lipid microembolization.

Authors:  E H Kincaid; T J Jones; D A Stump; W R Brown; D M Moody; D D Deal; J W Hammon
Journal:  Ann Thorac Surg       Date:  2000-10       Impact factor: 4.330

4.  Quality of processed blood for autotransfusion.

Authors:  G Shulman
Journal:  J Extra Corpor Technol       Date:  2000-03

5.  Detection and removal of fat particles from postoperative salvaged blood in orthopedic surgery.

Authors:  Gemma Ramírez; Adolfo Romero; Juan Jesús García-Vallejo; Manuel Muñoz
Journal:  Transfusion       Date:  2002-01       Impact factor: 3.157

Review 6.  Continuous and discontinuous cell-washing autotransfusion systems.

Authors:  Biao Dai; Lexin Wang; George Djaiani; C David Mazer
Journal:  J Cardiothorac Vasc Anesth       Date:  2004-04       Impact factor: 2.628

7.  Processing of stored packed red blood cells using autotransfusion devices decreases potassium and microaggregates: a prospective, randomized, single-blinded in vitro study.

Authors:  B Westphal-Varghese; M Erren; M Westphal; H Van Aken; C Ertmer; M Lange; M Booke
Journal:  Transfus Med       Date:  2007-04       Impact factor: 2.019

8.  Research on coagulation of unwashed shed blood after total knee replacement in Chinese patients.

Authors:  Zhen-Peng Guan; Jun Jiang; Hou-Shan Lv; Ning Wang
Journal:  Artif Cells Blood Substit Immobil Biotechnol       Date:  2008

9.  Qualitative assessment of blood washing with the continuous autologous transfusion system (CATS)

Authors:  B H Walpoth; N Eggensperger; B N Walpoth-Aslan; P Neidhart; M Lanz; R Zehnder; P J Spaeth; G Kurt; U Althaus
Journal:  Int J Artif Organs       Date:  1997-04       Impact factor: 1.595

10.  Fat elimination during intraoperative autotransfusion: an in vitro investigation.

Authors:  M Booke; M Fobker; D Fingerhut; M Storm; Y Mortlemans; H Van Aken
Journal:  Anesth Analg       Date:  1997-11       Impact factor: 5.108

View more
  2 in total

1.  Tangential flow filtration facilitated washing of human red blood cells: A proof-of-concept study.

Authors:  Shuwei Lu; Megan Allyn; Mitchell Weigand; Jeffrey J Chalmers; Andre F Palmer
Journal:  Vox Sang       Date:  2022-03-09       Impact factor: 2.996

2.  A novel autotransfusion device saving erythrocytes and platelets used in a 72 h survival swine model of surgically induced controlled blood loss.

Authors:  Kévin Schreiber; Benoit Decouture; Audrey Lafragette; Stéphane Chollet; Marine Bruneau; Maxence Nicollet; Catherine Wittmann; Francis Gadrat; Alexandre Mansour; Patricia Forest-Villegas; Olivier Gauthier; Gwenola Touzot-Jourde
Journal:  PLoS One       Date:  2022-03-24       Impact factor: 3.240

  2 in total