In vivo evaluation of Zr-based bulk metallic glass alloy intramedullary nails in rat femora.

Kazuhiro Imai1, Sachiko Hiromoto.   

Abstract

Zr-based bulk metallic glasses (BMG) show high corrosion resistance in vitro and higher strength and lower Young's modulus than crystalline alloys with the similar composition. This study aimed to perform an in vivo evaluation of Zr65Al7.5Ni10Cu17.5 BMG. Osteotomy of the femur was done in rats and stabilized with intramedullary nails made of Zr65Al7.5Ni10Cu17.5 BMG, Ti-6Al-4V alloy, or 316L stainless steel. Systemic and local effects of each type of nail were evaluated by measuring the levels of Cu and Ni in the blood and the surrounding soft tissue. Changes of the surface of each nail were examined by scanning electron microscopy (SEM). Healing of the osteotomy was evaluated by peripheral quantitative computed tomography and mechanical testing. No increase of Cu and Ni levels was recognized. Surface of the BMG showed no noticeable change, while Ti-6Al-4V alloy showed Ca and P deposition and 316L stainless steel showed surface irregularities and pitting by SEM observation. The stress strain index, maximum torque, torsional stiffness, and energy absorption values were larger for the BMG than those for Ti-6Al-4V alloy, although there was no significant difference. The Zr-based BMG can promote osteotomy healing as fast as Ti-6Al-4V alloy, with the possible advantage of the Zr-based BMG that bone bonding is less likely, allowing easier nail removal compared with Ti-6Al-4V alloy. The Zr-based BMG is promising for the use in osteosynthetic devices that are eventually removed.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24281655     DOI: 10.1007/s10856-013-5102-3

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  25 in total

Review 1.  Determination of mechanical properties of human femoral cortical bone by the Hopkinson bar stress technique.

Authors:  F Katsamanis; D D Raftopoulos
Journal:  J Biomech       Date:  1990       Impact factor: 2.712

Review 2.  The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus.

Authors:  K Choi; J L Kuhn; M J Ciarelli; S A Goldstein
Journal:  J Biomech       Date:  1990       Impact factor: 2.712

3.  The electrochemical evaluation of a Zr-based bulk metallic glass in a phosphate-buffered saline electrolyte.

Authors:  M L Morrison; R A Buchanan; R V Leon; C T Liu; B A Green; P K Liaw; J A Horton
Journal:  J Biomed Mater Res A       Date:  2005-09-01       Impact factor: 4.396

4.  Bone structure changes in the dog under rigid internal fixation.

Authors:  H K Uhthoff; F L Dubuc
Journal:  Clin Orthop Relat Res       Date:  1971 Nov-Dec       Impact factor: 4.176

5.  A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffness.

Authors:  S L Woo; W H Akeson; R D Coutts; L Rutherford; D Doty; G F Jemmott; D Amiel
Journal:  J Bone Joint Surg Am       Date:  1976-03       Impact factor: 5.284

6.  Effects of nail rigidity on fracture healing. Strength and mineralisation in rat femoral bone.

Authors:  S E Utvåg; O Reikerås
Journal:  Arch Orthop Trauma Surg       Date:  1998       Impact factor: 3.067

7.  On the biocompatibility of a novel Ti-based amorphous composite: structural characterization and in-vitro osteoblasts response.

Authors:  H Lefaix; A Asselin; P Vermaut; J-M Sautier; A Berdal; R Portier; F Prima
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

8.  On the biodegradability, mechanical behavior, and cytocompatibility of amorphous Mg72 Zn23 Ca5 and crystalline Mg70 Zn23 Ca5 Pd2 alloys as temporary implant materials.

Authors:  E Pellicer; S González; A Blanquer; S Suriñach; M D Baró; L Barrios; E Ibáñez; C Nogués; J Sort
Journal:  J Biomed Mater Res A       Date:  2012-08-28       Impact factor: 4.396

9.  Biomechanical effects of intramedullary reaming and nailing on intact femora in rats.

Authors:  A O Mølster
Journal:  Clin Orthop Relat Res       Date:  1986-01       Impact factor: 4.176

10.  Bone-bonding behavior of titanium alloy evaluated mechanically with detaching failure load.

Authors:  K Takatsuka; T Yamamuro; T Nakamura; T Kokubo
Journal:  J Biomed Mater Res       Date:  1995-02
View more
  1 in total

1.  In Vivo Evaluation of Bulk Metallic Glasses for Osteosynthesis Devices.

Authors:  Kazuhiro Imai; Sachiko Hiromoto
Journal:  Materials (Basel)       Date:  2016-08-09       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.