Literature DB >> 1254623

A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffness.

S L Woo, W H Akeson, R D Coutts, L Rutherford, D Doty, G F Jemmott, D Amiel.   

Abstract

Two internal-fixation plates with large differences in bending stiffness were applied to pairs of intact femora of six adult mongrel dogs to study the osteoporosis induced by rigid fixation. After nine and twelve months of plate application a significant, increased amount of bone atrophy was seen on the rigidly plated side. Biomechanical measurements of specimens from various segments of both femoral diaphyses showed the bones to have similar mechanical properties (as tissue), but different structural properties (as organ). These findings suggest that the osteoporosis due to rigid plate fixation occurs by thinning of the cortex rather than by reduction of the mechanical properties of the osseous tissue.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1254623

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  9 in total

1.  Intramedullary versus extramedullary fixation in the treatment of subtrochanteric femur fractures: A comprehensive systematic review and meta-analysis.

Authors:  Jie Wang; Haomin Li; Haobo Jia; Xinlong Ma
Journal:  Acta Orthop Traumatol Turc       Date:  2020-11       Impact factor: 1.511

2.  Functional strain as a determinant for bone remodeling.

Authors:  L E Lanyon
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

3.  Bone remodeling due to continuously applied loads.

Authors:  J B Meade; S C Cowin; J J Klawitter; W C Van Buskirk; H B Skinner
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

4.  Effect of animal species and age on plate-induced vascular damage in cortical bone.

Authors:  K Lippuner; R Vogel; S Tepic; B A Rahn; J Cordey; S M Perren
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

5.  In vivo evaluation of Zr-based bulk metallic glass alloy intramedullary nails in rat femora.

Authors:  Kazuhiro Imai; Sachiko Hiromoto
Journal:  J Mater Sci Mater Med       Date:  2013-11-27       Impact factor: 3.896

Review 6.  Biodegradable implants in traumatology: a review on the state-of-the-art.

Authors:  G O Hofmann
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

7.  Experimental lengthening of tibial diaphysis: gap healing with or without gradual distraction.

Authors:  O Korkala; E Karaharju; M Grönblad; K Aalto
Journal:  Arch Orthop Trauma Surg       Date:  1988

8.  In Vivo Evaluation of Bulk Metallic Glasses for Osteosynthesis Devices.

Authors:  Kazuhiro Imai; Sachiko Hiromoto
Journal:  Materials (Basel)       Date:  2016-08-09       Impact factor: 3.623

9.  Dual plating for fixation of humeral shaft fractures: A mechanical comparison of various combinations of plate lengths.

Authors:  Ahmet Karakasli; Onur Basci; Fatih Ertem; Eyad Sekik; Hasan Havitcioglu
Journal:  Acta Orthop Traumatol Turc       Date:  2016-07-29       Impact factor: 1.511

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.