Literature DB >> 24274974

Effect of upper strap downward displacement on n95 filtering facepiece respirator fit factors: a pilot study.

Raymond J Roberge1, Andrew J Palmiero, Yuewei Liu, Jung-Hyun Kim, Ziqing Zhuang.   

Abstract

Fifteen subjects underwent three replicates of quantitative respirator fit-testing with N95 filtering facepiece respirators that were donned with the upper strap high on the occiput, as per the manufacturers' donning instructions. Each fit-test was immediately followed by repeat fit-testing with the upper strap downwardly displaced to the level of the ear sulcus to determine any change in fit factors that might occur with upper strap downward slippage. A total of 35/45 (78%) initial fit-tests had a passing score (fit factor ≥ 100) with the top strap high on the occiput and 33/35 (94%) of these passed subsequent fit-testing after the top strap was displaced downward to the ear sulcus. Geometric mean fit factors for the initial passed fit-tests, and following downward strap displacement, were 217 ± 1.6 and 207 ± 1.9, respectively (p = 0.64). Downward displacement of the top strap did not significantly impact fit factors of N95 FFRs that had previously passed fit-testing.

Entities:  

Keywords:  N95 filtering facepiece respirators; displacement; fit factors; top strap

Mesh:

Year:  2014        PMID: 24274974      PMCID: PMC4466548          DOI: 10.1080/15459624.2013.866716

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  13 in total

1.  Effect of test exercises and mask donning on measured respirator fit.

Authors:  C D Crutchfield; E O Fairbank; S L Greenstein
Journal:  Appl Occup Environ Hyg       Date:  1999-12

2.  Tuberculosis isolation: comparison of written procedures and actual practices in three California hospitals.

Authors:  P M Sutton; M Nicas; R J Harrison
Journal:  Infect Control Hosp Epidemiol       Date:  2000-01       Impact factor: 3.254

3.  Longitudinal cephalometric standards for the neurocranium in Norwegians from 6 to 21 years of age.

Authors:  Stefan Axelsson; Inger Kjaer; Tore Bjørnland; Kari Storhaug
Journal:  Eur J Orthod       Date:  2003-04       Impact factor: 3.075

4.  Laboratory study to assess causative factors affecting temporal changes in filtering facepiece respirator fit: part I - pilot study.

Authors:  Ziqing Zhuang; Stacey Benson; Stephanie Lynch; Andy Palmiero; Raymond Roberge
Journal:  J Occup Environ Hyg       Date:  2011-12       Impact factor: 2.155

5.  Analysis of forces generated by n95 filtering facepiece respirator tethering devices: a pilot study.

Authors:  Raymond Roberge; George Niezgoda; Stacey Benson
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

6.  Evaluation of the benefit of the user seal check on N95 filtering facepiece respirator fit.

Authors:  Dennis J Viscusi; Michael S Bergman; Ziqing Zhuang; Ronald E Shaffer
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

7.  Evaluation of N95 respirator use as a tuberculosis control measure in a resource-limited setting.

Authors:  C R Biscotto; E R P Pedroso; C E F Starling; V R Roth
Journal:  Int J Tuberc Lung Dis       Date:  2005-05       Impact factor: 2.373

8.  Respirator-fit testing: does it ensure the protection of healthcare workers against respirable particles carrying pathogens?

Authors:  M C Lee; S Takaya; R Long; A M Joffe
Journal:  Infect Control Hosp Epidemiol       Date:  2008-12       Impact factor: 3.254

9.  Real-time fit of a respirator during simulated health care tasks.

Authors:  Jessica Hauge; Marc Roe; Lisa M Brosseau; Craig Colton
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

10.  Respirator donning in post-hurricane New Orleans.

Authors:  Kristin J Cummings; Jean Cox-Ganser; Margaret A Riggs; Nicole Edwards; Kathleen Kreiss
Journal:  Emerg Infect Dis       Date:  2007-05       Impact factor: 6.883

View more
  2 in total

1.  Stockpiled N95 Filtering Facepiece Respirator Polyisoprene Strap Performance.

Authors:  Dana R Rottach; Zhipeng Lei
Journal:  J Int Soc Respir Prot       Date:  2017

2.  Strap Performance of N95 Filtering Facepiece Respirators After Multiple Decontamination Cycles.

Authors:  Aaron W Richardson; Kent C Hofacre; Patrick H Keyes; Rachel M Thurston; John D Clay
Journal:  MRS Adv       Date:  2020-12-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.