Literature DB >> 33437533

Strap Performance of N95 Filtering Facepiece Respirators After Multiple Decontamination Cycles.

Aaron W Richardson1, Kent C Hofacre1, Patrick H Keyes1, Rachel M Thurston1, John D Clay1.   

Abstract

The Battelle Critical Care Decontamination System™ (CCDS™) decontaminates N95 filtering facepiece respirators (FFRs) using vapor phase hydrogen peroxide (VPHP) for reuse when there is a critical supply shortage. The Battelle CCDS received an Emergency Use Authorization (EUA) from the US Food and Drug Administration (FDA) in March 2020. This research focused on evaluating the mechanical properties of the straps as an indicator of respirator fit. The objective was to characterize the load generated by the straps following up to 20 don/doff and decontamination cycles in Battelle's CCDS. In general, the measured loads at 50 and 100% strains after 20 cycles were similar (±15%) to the as-received controls. Qualitatively, reductions in the load may be associated with loss of elasticity in the straps, potentially reducing the ability to obtain a proper fit. However, small changes in strap elasticity may not affect the ability to obtain a proper fit given the potential for variation in strap length and positioning on the head. Regardless, prior to reusing a N95 respirator, it is important to complete a visual inspection to ensure it is not damaged, malformed, or soiled. If so, it is recommended to discard the respirator and use a different one. Similarly, the respirator should be discarded if the wearer cannot obtain a proper fit during the user seal check. © The Materials Research Society 2020.

Entities:  

Year:  2020        PMID: 33437533      PMCID: PMC7790017          DOI: 10.1557/adv.2020.378

Source DB:  PubMed          Journal:  MRS Adv        ISSN: 2059-8521


  4 in total

1.  Analysis of forces generated by n95 filtering facepiece respirator tethering devices: a pilot study.

Authors:  Raymond Roberge; George Niezgoda; Stacey Benson
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

2.  Stockpiled N95 Filtering Facepiece Respirator Polyisoprene Strap Performance.

Authors:  Dana R Rottach; Zhipeng Lei
Journal:  J Int Soc Respir Prot       Date:  2017

3.  Effect of upper strap downward displacement on n95 filtering facepiece respirator fit factors: a pilot study.

Authors:  Raymond J Roberge; Andrew J Palmiero; Yuewei Liu; Jung-Hyun Kim; Ziqing Zhuang
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

4.  Evaluation of five decontamination methods for filtering facepiece respirators.

Authors:  Dennis J Viscusi; Michael S Bergman; Benjamin C Eimer; Ronald E Shaffer
Journal:  Ann Occup Hyg       Date:  2009-10-04
  4 in total