Prenatal ultrasound heating impacts on fluctuations in haematological analysis of Oryctolagus cuniculus.

Farah Wahida Ahmad Zaiki1, Sulaiman Md Dom, Hairil Rashmizal Abdul Razak, Hamzah Fansuri Hassan.   

Abstract

Prenatal Ultrasound (US) is commonly used as a routine procedure on pregnant women. It is generally perceived as a safe procedure due to the use of non-ionizing radiation. However, the neurotoxicity of diagnostic prenatal US was detected to have a correlation with high susceptibility to early developing fetus. This research involved in vivo experimental model by using 3(rd) trimester pregnant Oryctolagus cuniculus and exposing them to US exposures for 30, 60, and 90 minutes at their gestational day (GD) 28-29. The output power and intensities, spatial peak temporal average intensity (ISPTA) of US were varied from 0.4 to 0.7 W and 0.13 to 0.19 W/cm(2) respectively were tested initially in free-field, water. Haematological analysis was carried out to detect any changes in blood constituents. Statistically significant differences were detected in red blood cell (RBC) count (P<0.001), haemoglobin (Hb) concentration (P<0.001) and also platelet (PLT) count (P<0.001) in newborn of Oryctolagus cuniculus. These findings indicate the possibility of US heating in causing defects on studied animal.

Entities:  

Keywords:  Defect; haematological analysis; newborn; prenatal; ultrasound heating

Year:  2013        PMID: 24273744      PMCID: PMC3834203          DOI: 10.3978/j.issn.2223-4292.2013.10.05

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  13 in total

1.  Sinistrality--a side-effect of prenatal sonography: a comparative study of young men.

Authors:  H Kieler; S Cnattingius; B Haglund; J Palmgren; O Axelsson
Journal:  Epidemiology       Date:  2001-11       Impact factor: 4.822

2.  Complete blood cell counts in capillary and venous blood of healthy term newborns.

Authors:  N Ozbek; B Gürakan; S M Kayiran
Journal:  Acta Haematol       Date:  2000       Impact factor: 2.195

3.  Safety Statement, 2000 (reconfirmed 2003). International Society of Ultrasound in Obstetrics and Gynecology (ISUOG).

Authors:  J S Abramowicz; G Kossoff; K Marsal; G Ter Haar
Journal:  Ultrasound Obstet Gynecol       Date:  2003-01       Impact factor: 7.299

4.  WFUMB Symposium on Safety of Nonmedical Use of Ultrasound.

Authors:  Stanley B Barnett; Jacques S Abramowicz; Marvin C Ziskin; Karel Marsál; Michel Claudon
Journal:  Ultrasound Med Biol       Date:  2010-08       Impact factor: 2.998

Review 5.  Fetal ultrasound: mechanical effects.

Authors:  Melvin E Stratmeyer; James F Greenleaf; Diane Dalecki; Kjell A Salvesen
Journal:  J Ultrasound Med       Date:  2008-04       Impact factor: 2.153

Review 6.  Safety assurance in obstetrical ultrasound.

Authors:  Douglas L Miller
Journal:  Semin Ultrasound CT MR       Date:  2008-04       Impact factor: 1.875

Review 7.  Obstetric ultrasonography: a biophysical consideration of patient safety--the "rules" have changed.

Authors:  M W Miller; A A Brayman; J S Abramowicz
Journal:  Am J Obstet Gynecol       Date:  1998-07       Impact factor: 8.661

8.  Indicators of erythrocyte damage after microwave warming of packed red blood cells.

Authors:  Jan Hirsch; Axel Menzebach; Ingeborg Dorothea Welters; Gerald Volker Dietrich; Norbert Katz; Gunter Hempelmann
Journal:  Clin Chem       Date:  2003-05       Impact factor: 8.327

Review 9.  Hyperthermic teratogenicity, thermal dose and diagnostic ultrasound during pregnancy: implications of new standards on tissue heating.

Authors:  M W Miller; W L Nyborg; W C Dewey; M J Edwards; J S Abramowicz; A A Brayman
Journal:  Int J Hyperthermia       Date:  2002 Sep-Oct       Impact factor: 3.914

Review 10.  Effects of heat on embryos and foetuses.

Authors:  M J Edwards; R D Saunders; K Shiota
Journal:  Int J Hyperthermia       Date:  2003 May-Jun       Impact factor: 3.914

View more
  2 in total

1.  Effects of Low-Intensity Continuous Ultrasound on Hematological Parameters of Rats.

Authors:  M Mehrpour; A Shakeri-Zadeh; P Basir; B Jamei; H Ghaheri; M B Shiran
Journal:  J Biomed Phys Eng       Date:  2016-09-01

2.  Evaluation of the thermal effects of prenatal ultrasound on hematological analysis of young Oryctolagus Cuniculus.

Authors:  Iza Nurzawani Che Isa; Sulaiman Md Dom
Journal:  J Vet Med Sci       Date:  2016-05-21       Impact factor: 1.267