Literature DB >> 24245771

Electrochemical properties of nanostructured porous gold electrodes in biofouling solutions.

Jay Patel1, Logudurai Radhakrishnan, Bo Zhao, Badharinadh Uppalapati, Rodney C Daniels, Kevin R Ward, Maryanne M Collinson.   

Abstract

The effect of electrode porosity on the electrochemical response of redox active molecules (potassium ferricyanide, ruthenium(III) hexammine, and ferrocene methanol) in the presence of bovine serum albumin or fibrinogen was studied at macroporous (pore diameter: 1200 nm), hierarchical (1200/60 nm), and nanoporous (<50 nm) gold. These electrodes were prepared using standard templating or dealloying techniques, and cyclic voltammetry (CV) was utilized to evaluate the effect of protein adsorption on the electron transfer of the diffusing redox probes. Following exposure to albumin (or fibrinogen) under near neutral pH conditions, planar gold electrodes showed an immediate reduction in Faradaic peak current and increase in peak splitting for potassium ferricyanide. The rate at which the CV curves changed was highly dependent on the morphology of the electrode. For example, the time required for the Faradaic current to drop to one-half of its original value was 3, 12, and 38 min for planar gold, macroporous gold, and hierarchical gold, respectively. Remarkably, for nanoporous gold, only a few percent drop in the peak Faradaic current was observed after an hour in solution. A similar suppression in the voltammetry at planar gold was also noted for ruthenium hexammine at pH 3 after exposure to albumin for several hours. At nanoporous gold, no significant loss in response was observed. The order of performance of the electrodes as judged by their ability to efficiently transfer electrons in the presence of biofouling agents tracked porosity with the electrode having the smallest pore size and largest surface area, providing near ideal results. Nanoporous gold electrodes when immersed in serum or heparinized blood containing potassium ferricyanide showed ideal voltammetry while significant fouling was evident in the electrochemical response at planar gold. The small nanopores in this 3D open framework are believed to restrict the transport of large biomolecules, thus minimizing passivation of the inner surfaces while permitting access to small redox probes to efficiently exchange electrons.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24245771     DOI: 10.1021/ac403013r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  22 in total

1.  Minimum Bactericidal Concentration of Ciprofloxacin to Pseudomonas aeruginosa Determined Rapidly Based on Pyocyanin Secretion.

Authors:  Yi Liu; John H Moore; Glynis L Kolling; John S McGrath; Jason A Papin; Nathan S Swami
Journal:  Sens Actuators B Chem       Date:  2020-03-04       Impact factor: 7.460

2.  Interplay of Effective Surface Area, Mass Transport, and Electrochemical Features in Nanoporous Nucleic Acid Sensors.

Authors:  Jovana Veselinovic; Suzan AlMashtoub; Sachit Nagella; Erkin Seker
Journal:  Anal Chem       Date:  2020-07-14       Impact factor: 6.986

3.  Anomalous Trends in Nucleic Acid-Based Electrochemical Biosensors with Nanoporous Gold Electrodes.

Authors:  Jovana Veselinovic; Suzan Almashtoub; Erkin Seker
Journal:  Anal Chem       Date:  2019-08-30       Impact factor: 6.986

4.  Nanoporous Gold Biointerfaces: Modifying Nanostructure to Control Neural Cell Coverage and Enhance Electrophysiological Recording Performance.

Authors:  Christopher A R Chapman; Ling Wang; Hao Chen; Joshua Garrison; Pamela J Lein; Erkin Seker
Journal:  Adv Funct Mater       Date:  2016-12-12       Impact factor: 18.808

5.  Substrate Topography Guides Pore Morphology Evolution in Nanoporous Gold Thin Films.

Authors:  Christopher A R Chapman; Pallavi Daggumati; Shannon C Gott; Masaru P Rao; Erkin Seker
Journal:  Scr Mater       Date:  2016-01-01       Impact factor: 5.611

6.  Mechanisms of Reduced Astrocyte Surface Coverage in Cortical Neuron-Glia Co-cultures on Nanoporous Gold Surfaces.

Authors:  Christopher A R Chapman; Hao Chen; Marianna Stamou; Pamela J Lein; Erkin Seker
Journal:  Cell Mol Bioeng       Date:  2016-05-31       Impact factor: 2.321

Review 7.  Monitoring Severity of Multiple Organ Dysfunction Syndrome: New Technologies.

Authors:  Katri V Typpo; Hector R Wong; Stacey D Finley; Rodney C Daniels; Andrew J E Seely; Jacques Lacroix
Journal:  Pediatr Crit Care Med       Date:  2017-03       Impact factor: 3.624

8.  Carbon-Fiber Nanoelectrodes for Real-Time Discrimination of Vesicle Cargo in the Native Cellular Environment.

Authors:  James G Roberts; Edwin C Mitchell; Lars E Dunaway; Gregory S McCarty; Leslie A Sombers
Journal:  ACS Nano       Date:  2020-02-19       Impact factor: 15.881

9.  Whole Blood Redox Potential Correlates With Progressive Accumulation of Oxygen Debt and Acts as A Marker of Resuscitation in A Swine Hemorrhagic Shock Model.

Authors:  Rodney C Daniels; Hyesun Jun; Hakam Tiba; Brendan McCracken; Pilar Herrera-Fierro; Maryanne Collinson; Kevin R Ward
Journal:  Shock       Date:  2018-03       Impact factor: 3.454

10.  In-Line Analysis of Organ-on-Chip Systems with Sensors: Integration, Fabrication, Challenges, and Potential.

Authors:  Stefanie Fuchs; Sofia Johansson; Anders Ø Tjell; Gabriel Werr; Torsten Mayr; Maria Tenje
Journal:  ACS Biomater Sci Eng       Date:  2021-06-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.