Literature DB >> 24211194

Entrance skin dosimetry and size-specific dose estimate from pediatric chest CTA.

Sjirk J Westra1, Xinhua Li2, Kavita Gulati2, Sarabjeet Singh2, Bob Liu2, Mannudeep K Kalra2, Suhny Abbara2.   

Abstract

BACKGROUND: Size-specific dose estimate (SSDE), which corrects CT dose index (CTDI) for body diameter and is a better measure of organ dose than is CTDI, has not yet been validated in vivo.
OBJECTIVE: The purpose was to determine the correlation between SSDE and measured breast entrance skin dose (ESD) for pediatric chest CT angiography across a variety of techniques, scanner models, and patient sizes.
METHODS: During 42 examinations done on 4 different scanners over 7 years, we measured mid-sternal ESD as an approximation of breast dose with skin dosimeters. We recorded age, weight, effective tube current, kilovoltage potential, console CTDI, and dose-length product, from which we calculated effective dose. We measured effective chest diameter to convert CTDI to SSDE, and we correlated SSDE with measured ESD, using linear regression. We evaluated image quality to answer the clinical question.
RESULTS: Patient mean (±SD) age was 8.4 ± 6.1 years (median, 7.9 years; range, 0.02-19.5 years); mean weight was 35 ± 27 kg (median, 26 kg; range, 3.5-115 kg); effective chest diameter was 20 ± 7 cm (median, 19 cm; range, 10-35 cm). Mean effective dose was 2.9 ± 2.8 mSv (median, 2.2 mSv; range, 0.1-14.4 mSv). We observed a linear correlation (R(2) = 0.98, P < .005) between SSDE (mean, 11 ± 11mGy; median, 7 mGy; range, 0.5-40 mGy) and breast ESD (mean, 12 ± 11 mGy; median, 7 mGy; range, 0.3-44 mGy). Our doses, which compared favorably with those previously reported, decreased significantly (P < .05) during the course of our study, because of the introduction of automatic exposure control, low kilovoltage, and high pitch techniques. All studies were of diagnostic quality.
CONCLUSION: SSDE is a valid dose measure in children undergoing chest CT angiography over a wide range of scanner platforms, techniques, and patient sizes, and it may be used to model breast dose and to document the results of dose reduction strategies.
Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Breast dose; CT image quality; Chest CT angiography; Effective dose; Pediatric; Radiation dose

Mesh:

Year:  2013        PMID: 24211194     DOI: 10.1016/j.jcct.2013.08.002

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  8 in total

1.  Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT.

Authors:  Y Cui; M Huang; J Zheng; J Li; H Liu; C Liang
Journal:  Pediatr Cardiol       Date:  2015-08-14       Impact factor: 1.655

2.  Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT.

Authors:  Remy-Jardin Martine; Teresa Santangelo; Lucie Colas; Faivre Jean-Baptiste; Alain Duhamel; Antoine Deschildre; Jacques Remy
Journal:  Pediatr Radiol       Date:  2016-11-09

3.  Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors.

Authors:  Kazuki Takegami; Hiroaki Hayashi; Kenji Yamada; Yoshiki Mihara; Natsumi Kimoto; Yuki Kanazawa; Kousaku Higashino; Kazuta Yamashita; Fumio Hayashi; Tohru Okazaki; Takuya Hashizume; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2016-06-24

Review 4.  Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign.

Authors:  Cynthia K Rigsby; Sarah E McKenney; Kevin D Hill; Anjali Chelliah; Andrew J Einstein; B Kelly Han; Joshua D Robinson; Christina L Sammet; Timothy C Slesnick; Donald P Frush
Journal:  Pediatr Radiol       Date:  2018-01-01

5.  Size-specific dose estimates: Localizer or transverse abdominal computed tomography images?

Authors:  Sarvenaz Pourjabbar; Sarabjeet Singh; Atul Padole; Akshay Saini; Michael A Blake; Mannudeep K Kalra
Journal:  World J Radiol       Date:  2014-05-28

6.  Validity of the size-specific dose estimate in adults undergoing coronary CT angiography: comparison with the volume CT dose index.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Noriyuki Kai; Takeshi Nozaki; Yasuyuki Yamashita
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-06       Impact factor: 2.357

7.  Size-Specific Dose Estimates Based on Water-Equivalent Diameter and Effective Diameter in Computed Tomography Coronary Angiography.

Authors:  Jian Xu; Xiangquan Wang; Huawei Xiao; Jianguo Xu
Journal:  Med Sci Monit       Date:  2019-12-06

8.  Appraisal of radiation dose with 64-slice computed tomography perfusion in lung cancer patients with special reference to SSDE: An initial experience in a tertiary care hospital.

Authors:  Shuchi Bhatt; Ajai K Srivastava; Neha Meena; Shweta Thakur
Journal:  Indian J Radiol Imaging       Date:  2017 Oct-Dec
  8 in total