Literature DB >> 24210732

Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: a pilot study.

Frank S Andriessen1, David R Rijkens2, Wicher J van der Meer3, Daniel W Wismeijer4.   

Abstract

STATEMENT OF PROBLEM: In the past 5 years, the use of intraoral digitizers has increased. However, data are lacking on the accuracy of scanning implant restorative platforms for prosthodontics with intraoral digitizers.
PURPOSE: The purpose of this clinical pilot study was to assess the applicability and accuracy of intraoral scans by using abutments designed for scanning (scan abutments) in edentulous mandibles.
MATERIAL AND METHODS: Twenty-five participants with complete mandibular overdentures retained by 2 implants and frameworks were included in this study. Scan abutments were placed on the implants intraorally and scanned with the iTero intraoral scanner. Also, scan abutments were placed on the implant analogs of the definitive casts and scanned with an extraoral laboratory scanner (Lava Scan ST scanner). Two 3-dimensional computer-aided design models of the scan abutments with predetermined center lines were subsequently imported and registered, together with each of the scanned equivalents. The distance between the centers of the top of the scan abutments and the angulations between the scan abutments was assessed. These values were compared with the measurements made on the 3-dimensional scans of the definitive casts, which were the participants' original definitive casts used for fabrication of soldered bars. The threshold for distance error was established to be 100 μm.
RESULTS: Four of the 25 intraoral scans were not suitable for research because the intraoral scanner was not able to stitch the separate scans together. Five of the 21 suitable scans demonstrated an interimplant distance error >100 μm. Three of the 25 intraoral scans showed interimplant angulation errors >0.4 degrees. Only 1 scan showed both an acceptable interimplant distance (<100 μm) and an acceptable angulation error (<0.4 degrees).
CONCLUSIONS: Based on the intraoral scans obtained in this study, distance and angulation errors were too large to fabricate well-fitting frameworks on implants in edentulous mandibles. The main reason for the unreliable scans seemed to be the lack of anatomic landmarks for scanning.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24210732     DOI: 10.1016/j.prosdent.2013.07.010

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  37 in total

1.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

2.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

Review 3.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

4.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

5.  Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study.

Authors:  Gülce Çakmak; Hakan Yilmaz; Alejandro Treviño Santos; Ali Murat Kökat; Burak Yilmaz
Journal:  J Prosthodont       Date:  2021-09-21       Impact factor: 3.485

6.  Evaluation of intraoral digital impressions for obtaining gingival contour in the esthetic zone: accuracy outcomes.

Authors:  Donghao Wei; Ping Di; Jiehua Tian; Yijiao Zhao; Ye Lin
Journal:  Clin Oral Investig       Date:  2019-11-21       Impact factor: 3.573

7.  Influence of Scanning-Aid Materials on the Accuracy and Time Efficiency of Intraoral Scanners for Full-Arch Digital Scanning: An In Vitro Study.

Authors:  Hyun-Su Oh; Young-Jun Lim; Bongju Kim; Myung-Joo Kim; Ho-Beom Kwon; Yeon-Wha Baek
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

8.  A quantitative study of 3D-scanning frequency and Δd of tracking points on the tooth surface.

Authors:  Hong Li; Peijun Lyu; Yuchun Sun; Yong Wang; Xiaoyue Liang
Journal:  Sci Rep       Date:  2015-09-24       Impact factor: 4.379

9.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

Review 10.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.