Cihan Uras1, Deniz Eren Böler2, Ilknur Ergüner3, Ismail Hamzaoğlu4. 1. Department of General Surgery, Acıbadem University Medical Faculty, Istanbul, Turkey; Department of General Surgery, Acıbadem Bakırköy Hospital, Istanbul, Turkey; Department of General Surgery, Acıbadem Maslak Hospital, Istanbul, Turkey. 2. Department of General Surgery, Acıbadem University Medical Faculty, Istanbul, Turkey; Department of General Surgery, Acıbadem Bakırköy Hospital, Istanbul, Turkey. Electronic address: denniseren@yahoo.com. 3. Department of General Surgery, Acıbadem University Medical Faculty, Istanbul, Turkey; Department of General Surgery, Acıbadem Maslak Hospital, Istanbul, Turkey. 4. Department of General Surgery, Acıbadem Maslak Hospital, Istanbul, Turkey.
Abstract
BACKGROUND: Laparoendoscopic single-site surgery (LESS) has emerged as a result of a search for "pain-less" and "scar-less" surgery. Laparoendoscopic single-site cholecystectomy (LESS-C) is probably the most common application in general surgery, although it harbors certain limitations. It was proposed that the da Vinci Single-Site (Si) robotic system may overcome some of the difficulties experienced during LESS, providing three dimensional views and the ability to work in a right-handed fashion. Thirty-six robotic single port cholecystectomies (R-LESS-C) performed with the da Vinci Si robotic system are evaluated in this paper MATERIALS AND METHODS: R-LESS-C performed in 36 patients were reviewed. The data related to the perioperative period (i.e., anesthesia time, operation time, docking time, and console time) was recorded prospectively, whereas the hospitalization period, postoperative visual analogue scale (VAS) pain scores were collected retrospectively. RESULTS: A total number of 36 patients, with a mean age of 40.1 years (21-64 years), underwent R-LESS-C. There were five men and 31 women. The mean anesthesia and operation times were 79.3 minutes (45-130 minutes) and 61.8 minutes (34-110 minutes), respectively. The mean docking time was 9.8 minutes (4-30 minutes) and the mean console time was 24.9 minutes (7-60 minutes). The mean hospital stay was 1.05 days (1-2 days) and the mean pain score (VAS) was 3.6 (2-8) in the first 24 hours. Incisional hernia was recorded in one patient. CONCLUSION: R-LESS-C can be performed reliably with acceptable operative times and safety. The da Vinci Si robotic system may ease LESS-C. Two issues should be considered for routine use: expensive resources are needed and the incidence of incisional hernia may increase.
BACKGROUND: Laparoendoscopic single-site surgery (LESS) has emerged as a result of a search for "pain-less" and "scar-less" surgery. Laparoendoscopic single-site cholecystectomy (LESS-C) is probably the most common application in general surgery, although it harbors certain limitations. It was proposed that the da Vinci Single-Site (Si) robotic system may overcome some of the difficulties experienced during LESS, providing three dimensional views and the ability to work in a right-handed fashion. Thirty-six robotic single port cholecystectomies (R-LESS-C) performed with the da Vinci Si robotic system are evaluated in this paper MATERIALS AND METHODS:R-LESS-C performed in 36 patients were reviewed. The data related to the perioperative period (i.e., anesthesia time, operation time, docking time, and console time) was recorded prospectively, whereas the hospitalization period, postoperative visual analogue scale (VAS) pain scores were collected retrospectively. RESULTS: A total number of 36 patients, with a mean age of 40.1 years (21-64 years), underwent R-LESS-C. There were five men and 31 women. The mean anesthesia and operation times were 79.3 minutes (45-130 minutes) and 61.8 minutes (34-110 minutes), respectively. The mean docking time was 9.8 minutes (4-30 minutes) and the mean console time was 24.9 minutes (7-60 minutes). The mean hospital stay was 1.05 days (1-2 days) and the mean pain score (VAS) was 3.6 (2-8) in the first 24 hours. Incisional hernia was recorded in one patient. CONCLUSION:R-LESS-C can be performed reliably with acceptable operative times and safety. The da Vinci Si robotic system may ease LESS-C. Two issues should be considered for routine use: expensive resources are needed and the incidence of incisional hernia may increase.
Keywords:
da Vinci Single-Site robotic system; laparoendoscopic single site cholecystectomy (LESS-C); laparoendoscopic single site surgery (LESS); robotic single port cholecystectomy (R-LESS-C)
Authors: Amir Szold; Roberto Bergamaschi; Ivo Broeders; Jenny Dankelman; Antonello Forgione; Thomas Langø; Andreas Melzer; Yoav Mintz; Salvador Morales-Conde; Michael Rhodes; Richard Satava; Chung-Ngai Tang; Ramon Vilallonga Journal: Surg Endosc Date: 2014-11-08 Impact factor: 4.584
Authors: S Cianci; A Rosati; V Rumolo; S Gueli Alletti; V Gallotta; L C Turco; G Corrado; G Vizzielli; A Fagotti; F Fanfani; G Scambia; S Uccella Journal: World J Surg Date: 2019-10 Impact factor: 3.352
Authors: Anthony Gonzalez; Christian Hernandez Murcia; Rey Romero; Ernesto Escobar; Pedro Garcia; Gail Walker; Michelle Gallas; Eugene Dickens; Bruce McIntosh; William Norwood; Keith Kim; Jorge Rabaza; Don Parris Journal: Surg Endosc Date: 2015-11-05 Impact factor: 4.584
Authors: Vladimir Schraibman; Marina Gabrielle Epstein; Gabriel Naman Maccapani; Antônio Luiz de Vasconcellos Macedo Journal: Einstein (Sao Paulo) Date: 2015-09-18