Literature DB >> 24202615

Three-dimensional versus two-dimensional ultrasonographic assessment of peripheral enthesitis in spondylarthritis.

Oriane Mérot1, Pascale Guillot, Yves Maugars, Benoit Le Goff.   

Abstract

To compare the intra- and interobserver reliability of three-dimensional (3D) volumetric versus conventional two-dimensional (2D) power Doppler ultrasonography (US) in the assessment of peripheral enthesitis in spondylarthritis (SpA). Sixteen patients with SpA according to ASAS criteria were included. Two rheumatologists (one experimented in musculoskeletal US (sonographer 1) and one beginner (sonographer 2)) performed independently a 2D US scoring of the enthesis using the Madrid Sonographic Enthesis Index score followed by a 3D acquisition of the same entheseal sites. The reading of the 3D acquisition was performed a minimum of 1 week apart. Intraobserver reliability was evaluated by a second reading of the same images. The duration of 2D US scanning, 3D US acquisition and reading was recorded. Intraclass correlation coefficients (ICCs) were used for the reliability analysis. Intraobserver reproducibility was good to excellent for 2D US and good for 3D US (ICC (95 %CI) 2D US 0.776 (0.471-0.916) and 0.96 (0.892-0.986) and ICC (95 %CI) 3D US 0.796 (0.498-0.921) and 0.703 (0.325-0.886) for sonographer 1 and 2, respectively). Interobserver reliability was slightly better for 3D US than for 2D US (ICC (95 %CI) 0.776 (0.471-0.916) for 3D US versus 0.641 (0.221-0.859) for 2D US). The mean time (±SD) for 2D US scanning was 23 min (±4) whereas the mean time for 3D US volume acquisition and reading was 16.5 min (±2.6) (p < 0.001). 3D US showed good intra- and interobserver reliability in the assessment of enthesitis in SpA and shortened the needed time for scanning. It can be performed by a nonexperienced examiner without loss of reliability.

Entities:  

Mesh:

Year:  2013        PMID: 24202615     DOI: 10.1007/s10067-013-2424-y

Source DB:  PubMed          Journal:  Clin Rheumatol        ISSN: 0770-3198            Impact factor:   2.980


  17 in total

1.  Clinical and ultrasonography assessment of peripheral enthesitis in ankylosing spondylitis.

Authors:  Antonio Spadaro; Annamaria Iagnocco; Fabio Massimo Perrotta; Mariagrazia Modesti; Antongiulio Scarno; Guido Valesini
Journal:  Rheumatology (Oxford)       Date:  2011-08-28       Impact factor: 7.580

2.  Three-dimensional volumetric ultrasonography. Does it improve reliabililty of musculoskeletal ultrasound?

Authors:  E Naredo; I Möller; C Acebes; E Batlle-Gualda; E Brito; J J de Agustín; E de Miguel; A Martínez; L Mayordomo; C Moragues; E Rejón; A Rodríguez; J Uson; J Garrido
Journal:  Clin Exp Rheumatol       Date:  2010 Jan-Feb       Impact factor: 4.473

Review 3.  Plain X-rays in rheumatoid arthritis: overview of scoring methods, their reliability and applicability.

Authors:  D M van der Heijde
Journal:  Baillieres Clin Rheumatol       Date:  1996-08

4.  Entheseal ultrasound abnormalities in patients with SAPHO syndrome.

Authors:  Rubén Queiro; Sara Alonso; Mercedes Alperi; Mónica Fernández; Patricia Tejón; José L Riestra; Luis Arboleya; Javier Ballina
Journal:  Clin Rheumatol       Date:  2012-02-15       Impact factor: 2.980

5.  Enthesis erosion in spondyloarthritis is not a persistent structural lesion.

Authors:  Eugenio de Miguel; Sandra Falcao; Concepción Castillo; Chamaida Plasencia; Miriam García; Jaime C Branco; Emilio Martín-Mola
Journal:  Ann Rheum Dis       Date:  2011-08-27       Impact factor: 19.103

6.  The Assessment of SpondyloArthritis International Society classification criteria for peripheral spondyloarthritis and for spondyloarthritis in general.

Authors:  M Rudwaleit; D van der Heijde; R Landewé; N Akkoc; J Brandt; C T Chou; M Dougados; F Huang; J Gu; Y Kirazli; F Van den Bosch; I Olivieri; E Roussou; S Scarpato; I J Sørensen; R Valle-Oñate; U Weber; J Wei; J Sieper
Journal:  Ann Rheum Dis       Date:  2010-11-24       Impact factor: 19.103

7.  Three-dimensional Doppler sonographic vascular imaging in regions with increased MR enhancement in inflamed wrists of patients with rheumatoid arthritis.

Authors:  Johannes Strunk; Pascal Klingenberger; Katinka Strube; Georg Bachmann; Ulf Müller-Ladner; Alexander Kluge
Journal:  Joint Bone Spine       Date:  2006-03-29       Impact factor: 4.929

8.  Assessment of peripheral enthesitis in the spondylarthropathies by ultrasonography combined with power Doppler: a cross-sectional study.

Authors:  Maria-Antonietta D'Agostino; Roula Said-Nahal; Cécile Hacquard-Bouder; Jean-Louis Brasseur; Maxime Dougados; Maxime Breban
Journal:  Arthritis Rheum       Date:  2003-02

9.  Ultrasound imaging for the rheumatologist. XX. Sonographic assessment of hand and wrist joint involvement in rheumatoid arthritis: comparison between two- and three-dimensional ultrasonography.

Authors:  E Filippucci; G Meenagh; A Delle Sedie; F Salaffi; L Riente; A Iagnocco; C A Scirè; C Montecucco; S Bombardieri; G Valesini; W Grassi
Journal:  Clin Exp Rheumatol       Date:  2009 Mar-Apr       Impact factor: 4.473

10.  Validity of enthesis ultrasound assessment in spondyloarthropathy.

Authors:  E de Miguel; T Cobo; S Muñoz-Fernández; E Naredo; J Usón; J C Acebes; J L Andréu; E Martín-Mola
Journal:  Ann Rheum Dis       Date:  2008-04-07       Impact factor: 19.103

View more
  4 in total

1.  Ultrasound of knee osteoarthritis: interobserver agreement and correlation with Western Ontario and McMaster Universities Osteoarthritis.

Authors:  Ahmed Abdel Khalek Abdel Razek; Sherif Refaat El-Basyouni
Journal:  Clin Rheumatol       Date:  2015-06-20       Impact factor: 2.980

2.  Ultrasound findings of the painful ankle and foot.

Authors:  Suheil Artul; George Habib
Journal:  J Clin Imaging Sci       Date:  2014-05-27

3.  Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths - can feeding vessels lead to misinterpretation in Doppler-detected tenosynovitis?

Authors:  Mads Ammitzbøll-Danielsen; Iustina Janta; Søren Torp-Pedersen; Esperanza Naredo; Mikkel Østergaard; Lene Terslev
Journal:  Arthritis Res Ther       Date:  2016-03-18       Impact factor: 5.156

4.  Can power Doppler ultrasound of the entheses help in classifying recent axial spondyloarthritis? Data from the DESIR cohort.

Authors:  Cecile Poulain; Maria Antonietta D'Agostino; Severine Thibault; Jean Pierre Daures; Salah Ferkal; Philippe Le Corvoisier; Alain Rahmouni; Damien Loeuille; Maxime Dougados; Pascal Claudepierre
Journal:  RMD Open       Date:  2018-08-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.