Literature DB >> 20346243

Three-dimensional volumetric ultrasonography. Does it improve reliabililty of musculoskeletal ultrasound?

E Naredo1, I Möller, C Acebes, E Batlle-Gualda, E Brito, J J de Agustín, E de Miguel, A Martínez, L Mayordomo, C Moragues, E Rejón, A Rodríguez, J Uson, J Garrido.   

Abstract

OBJECTIVE: To compare the interobserver reliability of three-dimensional (3D) volumetric ultrasonography (US) and 2D real-time US in detecting inflammatory and destructive changes in rheumatoid arthritis (RA) wrist and hand.
METHODS: Two RA patients were selected by a rheumatologist who performed independently a grey-scale and power Doppler (PD) volumetric acquisition at three anatomic sites in their more symptomatic wrist/hand using two identical scanners equipped with 3D volumetric probe. Twelve rheumatologists expert in MSUS were randomly assigned to a US scanner and a patient. In the first part of the study, each group of experts blindly, independently, and consecutively performed a 2D real-time grey-scale and PD US investigation of inflammatory changes and/or bone erosions at the three anatomic sites. In the second part of the study, each group of investigators blindly evaluated the same pathologic changes in the 6 volumes from the patient not scanned by them.
RESULTS: The kappa values were higher for 3D volumetric US than for 2D US in the detection of synovitis/tenosyno-vitis (0.41 vs. 0.37) and PD signal (0.82 vs 0.45) and in the PD signal grading (0.81 vs. 0.55).
CONCLUSION: 3D volumetric US may improve the interobserver reliability in RA multicentre studies.

Entities:  

Mesh:

Year:  2010        PMID: 20346243

Source DB:  PubMed          Journal:  Clin Exp Rheumatol        ISSN: 0392-856X            Impact factor:   4.473


  7 in total

1.  Three-dimensional versus two-dimensional ultrasonographic assessment of peripheral enthesitis in spondylarthritis.

Authors:  Oriane Mérot; Pascale Guillot; Yves Maugars; Benoit Le Goff
Journal:  Clin Rheumatol       Date:  2013-11-08       Impact factor: 2.980

2.  The evolution of ultrasound in rheumatology.

Authors:  Taeyoung Kang; Stefano Lanni; Jackie Nam; Paul Emery; Richard J Wakefield
Journal:  Ther Adv Musculoskelet Dis       Date:  2012-12       Impact factor: 5.346

3.  Recent advances in imaging in psoriatic arthritis.

Authors:  René Panduro Poggenborg; Lene Terslev; Susanne Juhl Pedersen; Mikkel Ostergaard
Journal:  Ther Adv Musculoskelet Dis       Date:  2011-02       Impact factor: 5.346

4.  Level of agreement between three-dimensional volumetric ultrasound and real-time conventional ultrasound in the assessment of synovitis, tenosynovitis and erosions in rheumatoid arthritis patients.

Authors:  Carlos Acebes; Neil McKay; Anna Ciechomska; Nicola Alcorn; John P Harvie; Barbara Robson; Nico Groenendijk; Moira McDonald; Alison Wilson; Jesus Garrido
Journal:  Rheumatol Int       Date:  2016-11-28       Impact factor: 2.631

5.  Quantitative analysis of vascularization in the finger joints in patients with rheumatoid arthritis using three-dimensional volumetric ultrasonography with power Doppler.

Authors:  Tsuneo Watanabe; Masao Takemura; Masao Sato; Ayako Sekine; Daisuke Fukuoka; Mitsuru Seishima; Katsuji Shimizu; Toshio Matsuoka
Journal:  Clin Rheumatol       Date:  2011-07-28       Impact factor: 2.980

Review 6.  Role of ultrasound in managing rheumatoid arthritis.

Authors:  Hilde Berner Hammer; Lene Terslev
Journal:  Curr Rheumatol Rep       Date:  2012-10       Impact factor: 4.592

Review 7.  3D imaging options and ultrasound contrast agents for the ultrasound assessment of pediatric rheumatic patients.

Authors:  Tomasz Madej
Journal:  J Ultrason       Date:  2013-12-30
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.